Synchrotron radiation based XAFS analysis of the simulated nuclear waste glass samples prepared by bottom drain test in the full-scale mock-up melter (KMOC) (Contract research)

Okamoto, Yoshihiro  ; Nagai, Takayuki  ; Shiwaku, Hideaki   ; Kano, Shigeru; Himeno, Haruyuki*; Kobayashi, Hiroshi*; Nakatani, Mikio*

The chemical state and local structure of some elements in the simulated nuclear waste glass samples (20 batches) prepared by bottom drain test in the full scale mock-up tests using KMOC melter were investigated by synchrotron radiation based X-ray absorption fine structure (XAFS) analysis. As a result of the analysis of cerium element, it was confirmed that the oxidation proceeds gently as the batch advanced. For manganese, iron, and zinc, there was almost no difference between batches, which seemed to be stabilized by getting into the frame structure of the borosilicate glass. There were no elements that seemed to be clearly crystalline except for platinum group elements. Remarkable precipitation was hardly observed in zirconium and molybdenum with the imaging analysis.