Holding force tests of Curie Point Electro-Magnet in hot gas for passive shutdown system

Matsunaga, Shoko*; Matsubara, Shinichiro*; Kato, Atsushi ; Yamano, Hidemasa   ; D$"o$derlein, C.*; Guillemin, E.*; Hirn, J.*

This paper presents a design of Curie Point Electro-Magnet (CPEM) which will be installed as a passive shutdown system for a French Sodium-cooled Fast Reactor (ASTRID) development program which is conducted in collaboration between France and Japan. To confirm CPEM design validity, a qualification program for CPEM is developed on the basis of past comprehensive test series of Self-Actuated Shutdown System (SASS) in Japan. The main outcome of this paper is results of holding force tests in hot gas, which satisfy design requirements. Moreover, the result of a numerical magnetic field analysis showed the same tendency as that of the holding force test.