Parametric analysis of bubble and dissolved gas behavior in primary coolant system of sodium-cooled fast reactors

Matsushita, Kentaro ; Ito, Kei*; Ezure, Toshiki ; Tanaka, Masaaki  

A numerical simulation code named SYRENA has been developed in JAEA to analyze the behavior of entrained bubbles and dissolved gas in the primary coolant of sodium-cooled fast reactor (SFR). In the present study, a flow network model of SYRENA to a hypothetical pool type reactor was developed and the non-condensable gas behavior was investigated through the comparison with that in the loop type reactor. The effect of the dipped-plate (D/P) tentatively introduced into the pool-type reactor on the gas behavior was investigated through the parametric analyses about the sodium exchange flow rate through the D/P and the gas entrainment rate at the free surface. It was suggested that the increase in the exchange flow rate through the D/P doesn't always work to decrease the bubble volume in the primary coolant system.