Multiharmonic vector rf voltage control for wideband cavities driven by vacuum tube amplifiers in a rapid cycling synchrotron

Tamura, Fumihiko   ; Sugiyama, Yasuyuki*; Yoshii, Masahito*; Yamamoto, Masanobu   ; Omori, Chihiro*; Nomura, Masahiro  ; Shimada, Taihei ; Hasegawa, Katsushi*; Hara, Keigo*; Furusawa, Masashi*

Beam loading compensation in the rf cavities is a key for acceleration of high intensity beams in 3 GeV RCS of the J-PARC. Since we employ wideband magnetic alloy rf cavities for the J-PARC RCS and the wake voltage contains several harmonics, a multiharmonic beam loading compensation is required. The multiharmonic rf feedforward for the most important six harmonics is implemented in the existing low level rf (LLRF) control system, which has been working fairly well for acceleration of high intensity beams of up to 1 MW. However, we found the degradation of the performance for compensation of the feedforward with very high intensity beams. Therefore, a multiharmonic vector rf voltage control has been developed. The detail of system configuration, commissioning methodology, and beam test results using very high intensity beams are described. The beam loading by the 1 MW equivalent beam in the cavity is successfully compensated.