Update of MPS modules for J-PARC Linac and RCS

Takahashi, Hiroki  ; Hayashi, Naoki  ; Nishiyama, Koichi*; Suzuki, Takahiro*; Ishiyama, Tatsuya*

In the event of an abnormal situation, a machine protection system (MPS) that immediately inhibits the beam is indispensable to minimize the damage and the radioactivation by beam loss. The existing MPS was developed during the construction period of the J-PARC. Then, the system has been working stably for more than ten years. On the other hand, since there are many MPS modules that have been used from the beginning of J-PARC operation, it is important to systematically proceed with updating (replacement) of modules as a measure against aging of MPS. However, the main components of the existing MPS module have been discontinued. Therefore, it is indispensable to redesign the MPS modules in consideration of improvement such as the compatibility with existing modules and the miniaturization. In this paper, the development status of the new module and the update plan of MPS for Linac and RCS are detailed.