Refine your search:     
Report No.
 - 

Dry cleaning process test for fuel assembly of fast reactor plant system, 2; Laboratory scale test for fuel assembly and evaluation of the amount of residual sodium

Ide, Akihiro*; Kudo, Hideyuki*; Inuzuka, Taisuke*; Hara, Masahide*; Kato, Atsushi ; Ishikawa, Nobuyuki; Otaka, Masahiko; Nagai, Keiichi ; Saito, Junichi  ; Ara, Kuniaki 

A next generation SFR in Japan has adopted an advanced dry cleaning system which consists of the following process of argon gas blowing to reduce the amount of metallic sodium, moist argon gas blowing to deactivate the residual sodium, and direct storage in the SFP without using storage containers. This three-step process increases economic competitiveness and reduces waste products. In this Research and Development work, the amount of residual sodium and performance of the dry cleaning process were investigated. This paper describes experimental and analytical work for all parts of a fuel assembly except for a fuel pin bundle.