Validation study of SAS4A code for the unprotected loss-of-flow accident in an SFR

Ishida, Shinya  ; Kawada, Kenichi   ; Fukano, Yoshitaka  

The Phenomena Identification and Ranking Table (PIRT) approach was applied to the validation of SAS4A code in order to indicate the reliability of SAS4A code sufficiently and objectively. Based on this approach, issue and objective were clarified, plant design and scenario were defined, FOM and key phenomena were selected, and the code validation test matrix was completed with the results of investigation about analysis models and test cases. The results of the test analysis corresponding to this matrix show that the SAS4A models required for the IP evaluation were sufficiently validated. Furthermore, the validation with this matrix is highly reliable, since this matrix represents the comprehensive validation that also considers the relation between physical phenomena. In this study, the reliability and validity of SAS4A code were significantly enhanced by using PIRT approach to the sufficient level for CDA analyses in SFR.