Low-power proton beam extraction by the bright continuous laser using the 3-MeV negative-hydrogen linac in Japan Proton Accelerator Research Complex

Takei, Hayanori   ; Tsutsumi, Kazuyoshi*; Meigo, Shinichiro   

The Japan Atomic Energy Agency (JAEA) has designed a Transmutation Physics Experimental Facility (TEF-P) as an experimental facility in the Japan Proton Accelerator Research Complex (J-PARC). The TEF-P is a critical assembly driven by a low-power proton beam, a maximum of 10 W, which is extracted from a high-power beam source, such as 250 kW of 400 MeV proton beam of the J-PARC Linac. To extract such a low-power proton beam from the high-power proton beam, we developed a laser charge exchange (LCE) device and employed its technique, which is one of the non-contact beam extraction techniques. For the proof of performance of the LCE device to the TEF-P, a low-power proton beam was extracted using a negative-hydrogen (H$$^{-}$$) Linac having an energy of 3 MeV, and a bright continuous laser. Proton beam with the power of 0.57 mW was successfully extracted with a laser stripping efficiency of $$2.3times10^{-5}$$. These experimental values are in good agreement with the estimated ones.