Refine your search:     
Report No.
 - 

Mapping measurement for beam energy position monitor system for RIKEN superconducting acceleration cavity

Watanabe, Tamaki*; Toyama, Takeshi*; Hanamura, Kotoku*; Imao, Hiroshi*; Kamigaito, Osamu*; Kamoshida, Atsushi*; Kawachi, Toshihiko*; Koyama, Ryo*; Sakamoto, Naruhiko*; Fukunishi, Nobuhisa*; Fujimaki, Masaki*; Miura, Akihiko ; Miyao, Tomoaki*; Yamada, Kazunari*; Watanabe, Yutaka*

Upgrades for the RIKEN heavy-ion linac (RILAC) involving a new superconducting linac (SRILAC) are currently underway at the RIKEN radioactive isotope beam factory (RIBF). It is crucially important to develop nondestructive beam measurement diagnostics. We have developed a beam energy position monitor (BEPM) system which can measure not only the beam position but also the beam energy simultaneously by measuring the time of flight of the beam. We fabricated 11 BEPMs and completed the position calibration to obtain the sensitivity and offset for each BEPMs. The position accuracy has been achieved to be less than $$pm$$ 0.1 mm by using the mapping measurement.

Accesses

:

- Accesses

InCites™

: