Refine your search:     
Report No.
 - 

Conversion factors bridging radioactive fission product distributions in the primary containment vessel of Fukushima Daiichi NPP and dose rates measured by the containment atmosphere monitoring system

Uchida, Shunsuke; Pellegrini, M.*; Naito, Masanori*

Multi-term FP analysis procedures were developed to determine FP distribution all over F1 not only for analyzing accident propagation but also for planning its decommissioning projects. They should be validated based on the measured FP data. One of the useful tools for their validation was application of the dose rate data monitored by the containment atmosphere monitoring system (CAMS). However, in order to compare the data with different characteristics and dimensional units, e.g., FP distribution (kg, Bq) and dose rate (Sv/h), application of the conversion factors bridging them would be effective and useful. In order to prepare speedy, easy-to-handle and tractable procedures to calculate radiation dose rates at the CAMS detector locations, dose rate conversion factors were determined for major source locations and major radionuclides. The dose rates could be easily calculated by multiplying FP amounts obtained with the multiterm FP analysis procedures by the conversion factors.