Corrosion test of T91 and SUS316L in liquid lead bismuth at 500$$^{circ}$$C

Komatsu, Atsushi ; Kato, Chiaki   

A corrosion test was conducted in a molten lead-bismuth eutectic alloy having an oxygen concentration of about 10$$^{-7}$$ and 10$$^{-5}$$wt%. Although the average amount of corrosion of SUS316L was small, localized corrosion became severe when the oxygen concentration decreased. The average amount of corrosion of T91 was larger than that of SUS316L and the amount of corrosion increased slightly as the oxygen concentration increased, but localized corrosion was not severe.