Hydrogen isotope separation used graphene-palladium electrode

Yasuda, Satoshi   ; Matsushima, Hisayoshi*; Asaoka, Hidehito  ; Fukutani, Katsuyuki

We evaluated H/D separation factor of graphene-palladium electrode in hydrogen pumping cell. We revealed that in case of palladium electrode, the separation factor hardly increases while the factor significantly increased for graphene-palladium electrode.