3D FEM soil-structure interaction analysis for Kashiwazaki-Kariwa Nuclear Power Plant considering soil separation and sliding
Ichihara, Yoshitaka*; Nakamura, Naohiro*; Moritani, Hiroshi*; Choi, B.
; Nishida, Akemi
![](/search/images/KAKENHIlogoS.jpg)
The objective of this study is the improvement of response evaluations of structures, facilities and equipment in evaluation of three-dimensional seismic behavior of nuclear power plant facilities, by three-dimensional finite element method model, including separation and sliding between the soil and the basement walls. To achieve this, simulation analyses of Kashiwazaki Kariwa nuclear power plant unit 7 reactor building under the 2007 Niigataken-chuetsu-oki earthquake event were carried out. These simulation analyses consider soil-structure interaction using a three-dimensional finite element method model in which the soil and building are three-dimensionally modeled by the finite element method. It is found that basemat uplift is generated on east side of the basemat edge, and this has an important influence on the results. The importance is evidenced by the difference of local response in soil pressure characteristics beneath the edge of basemat, the soil pressure characteristics along the east side of basement wall and the maximum acceleration response at the west end of the embedded surface. Although, in this particular study, basemat uplift, separation and sliding have only a relatively small influence on the maximum acceleration response of embedded surface and the soil pressure characteristics along the basement walls and beneath the basemat, under strong earthquake motion, these influences can be significant, therefore appropriate evaluation of this effect should be considered.