High density mapping systems for SRF cavities

Fuwa, Yasuhiro   ; Iwashita, Yoshihisa*; Kuriyama, Yasutoshi*; Tongu, Hiromu*; Hayano, Hitoshi*; Geng, R. L.*

In order to evaluate the performance of a superconducting cavity, we are developing a mapping system to measure the distribution of cavity temperature, field emission X-rays, and trapped magnetic flux with high positional resolution. In order to construct a system with high positional resolution, a large number of sensors are required. However, as the number of sensors increases, so does the amount of wiring, which increases the complexity of the wiring in the cryogenic apparatus, and also increases the heat transfer through the wiring, which disturb efficient operation of cavity tests. We are developing an efficient mapping system with a multiplexer that scans the readout signal on the same circuit as the sensor in the cryogenic dewar where the cavity test is conducted. In this presentation, we report the outline and test results of the mapping system under development