Refine your search:     
Report No.
 - 

Measurement of Gd$$^{3+}$$ ion emission lifetime in aqueous solution of Gd sulfate

Iwata, Yoshihiro   ; Sekiya, Hiroyuki*; Ito, Chikara   

We are studying the measurement of Gd$$^{3+}$$ ion emission lifetime in aqueous solution of Gd sulfate. In this study, a nanosecond pulsed laser at 266 nm was used as the excitation light source, and emission at 312 nm was detected by a photomultiplier tube attached to a monochromator. The emission lifetime was measured to be about 2 ms, which was longer than that of other lanthanoid ions.