Analytical study on mechanism of heat transfer from molten pool to duct wall in EAGLE ID1 in-pile test

Yao, Y.*; Zhang, T.*; Morita, Koji*; Liu, X.*; Liu, W.*; Imaizumi, Yuya ; Kamiyama, Kenji  

A large-scale particle based simulation of the in-pile test EAGLE ID1, which demonstrated the effectiveness of the FAIDUS concept proposed for sodium-cooled fast reactors, was performed to clarify the mechanisms involved in duct wall failure.