Development of a portable $$beta$$-ray dust monitor for highly-concentrated airborne contaminants

Sagawa, Naoki; Fujisawa, Makoto; Hosomi, Kenji  ; Morishita, Yuki   ; Takada, Chie 

Radioactivity concentrations of airborne dust are important measurements because they are used to protect workers from intakes and to assess internal exposure doses. Therefore, we developed a portable $$beta$$-ray dust monitor by using an ultra-thin plastic scintillator, which is designed for continuous monitoring of highly-concentrated airborne contaminants ($$>$$ 10$$^{-2}$$ Bq/cm$$^{3}$$, equivalent to 30 times larger than the derived air concentration of $$^{90}$$Sr) such as a decommissioning work in the Fukushima Daiichi Nuclear Power Plant. From the performance test results, it is evaluated that the developed portable $$beta$$-ray dust monitor is functional in continuous monitoring with an airborne concentration of 1 Bq/cm$$^{3}$$.