Refine your search:     
Report No.
 - 

BWR lower plenum damage by reaction between metallic debris and structural materials

Sato, Takumi ; Shimomura, Kenta ; Nagae, Yuji 

During the severe accident at the Fukushima Daiichi Nuclear Power Station, a molten metal pool formed by an analytical approach might contribute to the initial failure of the lower plenum. To understand this failure behavior, high-temperature reaction tests were conducted using simulated metal debris and a test bundle that simulated the structure of the control rod drive mechanism in the lower plenum.