Investigation of deposits on filter element of primary gas circulators in HTTR
Hasegawa, Toshinari ; Nagasumi, Satoru; Nemoto, Takahiro; Nakajima, Kunihiro; Yokoyama, Keisuke ; Fujiwara, Yusuke ; Arakawa, Ryoki ; Iigaki, Kazuhiko ; Inoi, Hiroyuki; Kawamoto, Taiki
The filter element of the primary gas circulators (PGC) in High Temperature engineering Test Reactor (HTTR) and its deposits were investigated by Scanning Electron Microscope (SEM) observation and Energy Dispersive X-ray spectroscopy (EDX) analysis to find the cause of the increase of the filter differential pressure during the operation in 2021. SEM observation showed that the clumpy deposits and fibrous deposits smaller than the filtration pore size and the rod-shaped deposits larger than the pore size were present on the filter element. EDX analysis showed that the clumpy deposits and fibrous deposits could include silicone oil in the primary helium purification system (PHPS) gas circulators and that the rod-shaped deposits were thermal insulators inside of the co-axial double pipes in the primary cooling system. It is considered that silicone oil leaked from the PHPS gas circulators due to deterioration in the absorption performance of the activated charcoal filter. Next, it could be vaporized and reach PGC's filter element after passing through the reactor core. Since those deposits including silicone oil were present over the entire surface of the filter element, the filter differential pressure could be increased due to a reduction in the pore size and a rise in its flow resistance. The thermal insulator was unrelated to filter clogging because it was present mainly in the lower part of the filter element. Therefore, silicone oil could increase the filter differential pressure, and the graphite powder, which is the cause of the previous issue was unrelated.