Characteristics of smartphone-wirelessly-connected personal dosemeters

Mikami, Satoshi   ; Tokiyoshi, Masanori*; Sato, Rina*; Tanaka, Daisuke*; Yoshimura, Kazuya  

Taisei Corporation and Infocube LAFLA Co., Ltd. have developed the smartphone-wirelessly-connected dosemeters, aiming to apply it to real-time exposure management of multiple decontamination workers. In order to grasp the basic characteristics of the developed dosemeters, they were calibrated and tested their characteristics such as energy dependency, angle of incidence dependency, etc. at photon calibration fields in Japan Atomic Energy Agency. The results showed generally good characteristics in each test. We evaluated that the dosemeters can be effectively used for decontamination work.