Refine your search:     
Report No.
 - 

Development of a simplified boiling model applied for large-scale detailed two-phase flow simulations based on the VOF method

Ono, Ayako ; Sakashita, Hiroto*; Yamashita, Susumu   ; Suzuki, Takayuki*; Yoshida, Hiroyuki  

Japan Atomic Energy Agency (JAEA) is developing the evaluation method for a two-phase flow in the reactor core using simulation codes based on the Volume Of Fluid (VOF) method. JAEA started developing a Simplified Boiling Model (SBM) for the large-scale two-phase flow in the fuel assemblies. In the SBM, the motion and growth equations of the bubble are solved to obtain their diameter and time length at the detachment, of which size scale is within/around the calculation grid size of the numerical simulation. JUPITER calculates the bubble behavior with a scale of more than several $$mu$$m. In this study, the convection boiling on a vertical heating surface is simulated using the developed SBM. The comparison between the simulation and experimental results showed good reproducibility of the heat flux and velocity dependency on the passage period of the bubble.

Accesses

:

- Accesses

InCites™

:

Altmetrics

: