Development of zeolite column adsorption dynamics simulation code (ZAC)

Yamagishi, Isao ; Hato, Shinji*; Nishihara, Kenji  ; Tsubata, Yasuhiro   ; Sagawa, Yusuke*

Adsorption columns filled with zeolite are used to treat contaminated water containing radioactive cesium generated by the Fukushima Daiichi Nuclear Power Station accident. As the contaminated water treatment progresses, the radioactive cesium in the adsorption column becomes highly concentrated, and the adsorption column becomes a high radiation source. To evaluate the radiation effects such as decay heat and radiolytic hydrogen production in the adsorption column, the concentration of radioactive cesium in the adsorption column is necessary, but since it is difficult to evaluate the concentration by measurement, it is estimated by simulation. In this research, a zeolite column adsorption dynamics simulation (Zeolite Adsorption Column: ZAC) code was developed to calculate the concentration of radioactive materials such as radioactive cesium in a zeolite filled adsorption column when they are injected into the column. The code was validated through comparison of calculation results with existing codes and experimental results of small column tests. This report presents the details of the model, the handling of the code, and the validity of the results for the developed code.