Numerical investigation of the accuracy of a conductance-type wire-mesh sensor for a single spherical bubble and bubbly flow
Uesawa, Shinichiro
; Ono, Ayako
; Nagatake, Taku
; Yamashita, Susumu
; Yoshida, Hiroyuki

We performed electrostatic simulations of a wire-mesh sensor (WMS) for a single spherical bubble and bubbly flow to clarify the accuracy of the WMS. The electrostatic simulation for the single bubble showed the electric current density distribution and the electric current path from the excited transmitter to receivers for various bubble locations. It indicated systematic errors based on the nonuniform current density distribution around the WMS. The electrostatic simulation for the bubbly flow calculated by the computational fluid dynamics code, JAEA Utility Program for Interdisciplinary Thermal-hydraulics Engineering and Research (JUPITER), indicated that the WMS had difficulty in quantitatively measuring the intermediate values of the instantaneous void fraction between 0 and 1 because they cannot be estimated by previous transformation methods from the WMS signal to the void fraction, such as linear approximation or Maxwell's equation, and have a significant deviation of the void fraction of
0.2 for the WMS signal. However, the electrostatic simulation indicated that the time-averaged void fractions around the center of the flow channel can be estimated using linear approximation, and the time-averaged void fraction near the wall of the flow channel can be estimated using Maxwell's equation.