A dedicated isochronous storage ring, named the Rare-RI Ring, was constructed at the RI Beam Factory of RIKEN, aiming at precision mass measurements of nuclei located in uncharted territories of the nuclear chart. The Rare-RI Ring employs the isochronous mass spectrometry technique with the goal to achieve a relative mass precision of 10$$^{-6}$$ within a measurement time of less than 1 ms. The performance of the facility was demonstrated through mass measurements of neutron-rich nuclei with well-known masses. Velocity or magnetic rigidity is measured for every particle prior to its injection into the ring, wherein its revolution time is accurately determined. The latter quantity is used to determine the mass of the particle, while the former one is needed for nonisochronicity corrections. Mass precisions on the order of 10$$^{-5}$$ were achieved in the first commissioning, which demonstrates that the Rare-RI Ring is a powerful tool for mass spectrometry of short-lived nuclei.