Refine your search:     
Report No.
 - 

Cement solidification of Fugen concentrated liquid waste, 2; Beaker scale cold test for determination of mixing conditions

Hanaki, Shotaro  ; Morita, Sakura; Maruyama, Shumpei ; Hojo, Yuki; Nagahama, Aoi; Kudo, Isamu; Sato, Junya ; Tabata, Koichi ; Soejima, Goro ; Nakamura, Yasuyuki 

Waste packages are needed to satisfy the waste acceptance criteria (WAC) set by the landfill site. To produce sound waste packages that meet such criteria as uniaxial compressive strength and porosity, it is necessary to establish the range of parameters such as mixing time, rotation speed of mixing blade, and amount of cement. This presentation reports on the Beaker scale cold test conducted to determine the cement-to-waste ratio (C/W) which affects the number of waste packages produced and uniaxial compressive strength.