Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 125

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of a radioactive substance detection system integrating a Compton camera and a LiDAR camera with a hexapod robot

Sato, Yuki; Kakuto, Takeshi*; Tanaka, Takayuki*; Shimano, Hiroyuki*; Morohashi, Yuko; Hatakeyama, Tomoyoshi*; Nakajima, Junsaku; Ishiyama, Masahiro

Nuclear Instruments and Methods in Physics Research A, 1063, p.169300_1 - 169300_7, 2024/06

Journal Articles

Journal Articles

Development of contamination detection system combined with various remote devices

Morishita, Yuki; Miyamura, Hiroko; Sato, Yuki; Oura, Masatoshi*

Radiation Measurements, 171, p.107064_1 - 107064_7, 2024/02

 Times Cited Count:0 Percentile:0.05(Nuclear Science & Technology)

The detection of alpha and beta contamination locations is important for decontaminating nuclear facilities. In the high radiation dose rate environment at the decommissioning sites, the contamination measurement by the workers is not effective. Thus, we developed a remote automatic contamination measurement system using a new scintillator-based detector. A 50 mm$$phi$$ $$times$$ 100-$$mu$$m-thick YAlO$$_{3}$$(Ce)(YAP:Ce) scintillator was coupled with a flat panel-type multianode photomultiplier tube. The detector was installed downwards at the bottom of a robot. It has an energy measurement capability, and the energy measurement could discriminate the alpha particles from the beta and $$^{222}$$Rn alpha particles. With the energy information, alpha and beta particles could be identified and mapped simultaneously. In addition, a slow-moving robot could be used to obtain statistically sufficient counts in a single run measurement, allowing the evaluation of surface contamination density using only alpha particles. The remote automatic contamination measurement system will be useful in visualizing the contamination distribution in environments that are inaccessible to workers.

Journal Articles

Radioactivity estimation of multiple radiation sources using a Compton camera to investigate radioactively contaminated objects

Sato, Yuki

Applied Radiation and Isotopes, 203, p.111083_1 - 111083_9, 2024/01

 Times Cited Count:0 Percentile:0.01(Chemistry, Inorganic & Nuclear)

Journal Articles

Demonstration of radioactive contamination visualization using the integrated Radiation Imaging System; iRIS

Sato, Yuki

Chino To Joho, 35(4), p.81 - 86, 2023/11

no abstracts in English

Journal Articles

Radiation imaging of a highly contaminated filter train inside Fukushima Daiichi Nuclear Power Station Unit 2 using an integrated Radiation Imaging System based on a Compton camera

Sato, Yuki; Terasaka, Yuta

Journal of Nuclear Science and Technology, 60(8), p.1013 - 1026, 2023/08

 Times Cited Count:5 Percentile:97.88(Nuclear Science & Technology)

Journal Articles

Visualization software for radioactive contamination based on Compton camera: COMRIS

Sato, Yuki; Minemoto, Kojiro*; Nemoto, Makoto*

Radiation Protection Dosimetry, 199(8-9), p.1021 - 1028, 2023/06

 Times Cited Count:1 Percentile:63.33(Environmental Sciences)

Journal Articles

Identification of depth location of a radiation source by measurement from only one direction using a Compton camera

Sato, Yuki

Applied Radiation and Isotopes, 195, p.110739_1 - 110739_9, 2023/05

 Times Cited Count:2 Percentile:84.55(Chemistry, Inorganic & Nuclear)

Journal Articles

3D visualization of radioactive contamination using an integrated Radiation Imaging System (iRIS)

Sato, Yuki

Isotope News, (781), p.19 - 23, 2022/06

no abstracts in English

Journal Articles

Radiation imaging using an integrated radiation imaging system based on a compact Compton camera under Unit 1/2 exhaust stack of Fukushima Daiichi Nuclear Power Station

Sato, Yuki; Terasaka, Yuta

Journal of Nuclear Science and Technology, 59(6), p.677 - 687, 2022/06

 Times Cited Count:17 Percentile:94.96(Nuclear Science & Technology)

Journal Articles

Development of an integrated Radiation Imaging System

Sato, Yuki

Kensa Gijutsu, 27(5), p.9 - 15, 2022/05

no abstracts in English

Journal Articles

Activities in the field of radiation engineering for 10 years after the 1F accident and future prospects, 2; Radiation measurement and mapping technology developed/applied after the FDNPS accident

Torii, Tatsuo*; Sanada, Yukihisa; Sato, Yuki

Nihon Genshiryoku Gakkai-Shi ATOMO$$Sigma$$, 64(1), p.17 - 22, 2022/01

Ten years have passed since the accident at the Fukushima Daiichi Nuclear Power Station. Due to the accident, radioactive materials were widely diffused and deposited not only in the building and site of the Fukushima Daiichi Nuclear Power Station but also in the environment. Demand has increased, and the introduction and development of radiation imaging equipment called gamma cameras and mapping of radiation distribution in the environment have been promoted. Here, we will introduce the radiation distribution measurement technology that has been developed and operated after the accident, and describe the future prospects.

Journal Articles

Monitoring technique for detection of nuclear and radioactive materials on major public events

Mochimaru, Takanori*; Koizumi, Mitsuo; Takahashi, Tone; Hironaka, Kota; Kimura, Yoshiki; Sato, Yuki; Terasaka, Yuta; Yamanishi, Hirokuni*; Wakabayashi, Genichiro*

Dai-42-Kai Nihon Kaku Busshitsu Kanri Gakkai Nenji Taikai Kaigi Rombunshu (Internet), 4 Pages, 2021/11

no abstracts in English

Journal Articles

Three-dimensional visualization of a beta-emitting nuclide by combining a directional Geiger-Mueller counter and Structure from Motion

Sato, Yuki; Minemoto, Kojiro*; Nemoto, Makoto*

Journal of Instrumentation (Internet), 16(10), p.C10008_1 - C10008_8, 2021/10

 Times Cited Count:3 Percentile:27.06(Instruments & Instrumentation)

Journal Articles

Feasibility study of the one-dimensional radiation distribution sensing method using an optical fiber sensor based on wavelength spectrum unfolding

Terasaka, Yuta; Watanabe, Kenichi*; Uritani, Akira*; Yamazaki, Atsushi*; Sato, Yuki; Torii, Tatsuo; Wakaida, Ikuo

Journal of Nuclear Engineering and Radiation Science, 7(4), p.042002_1 - 042002_7, 2021/10

For the application in the measurement of the high dose rate hot spots inside the Fukushima Daiichi Nuclear Power Station (FDNPS) buildings, we propose a novel one-dimensional radiation distribution sensing method using an optical fiber sensor based on wavelength spectrum unfolding. The proposed method estimates the incident position of radiation to the fiber by the unfolding of the wavelength spectrum output from the fiber edge using the fact that the attenuation length of light along the fiber depends on the wavelength. Because this method measures the integrated light intensity, this method can avoid the problem of counting loss and signal pile-up, which occurs in the radiation detector with pulse counting mode under high dose rate field. Through basic experiments using the ultraviolet light source and $$^{90}$$Sr/$$^{90}$$Y radioactive point source, basic properties of source position detection were confirmed.

Journal Articles

Visualization of radioactive substances using a freely moving gamma-ray imager based on Structure from Motion

Sato, Yuki; Minemoto, Kojiro*; Nemoto, Makoto*; Torii, Tatsuo

Journal of Nuclear Engineering and Radiation Science, 7(4), p.042003_1 - 042003_12, 2021/10

Journal Articles

Simulation study of a shield-free directional gamma-ray detector using Small-Angle Compton Scattering

Kitayama, Yoshiharu; Terasaka, Yuta; Sato, Yuki; Torii, Tatsuo

Journal of Nuclear Engineering and Radiation Science, 7(4), p.042006_1 - 042006_7, 2021/10

125 (Records 1-20 displayed on this page)