Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 45

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Analysis work report on removal of spent fuel sheared powder for decommissioning of main plant

Aoya, Juri; Mori, Amami; Sato, Hinata; Kono, Soma; Morokado, Shiori; Horigome, Kazushi; Goto, Yuichi; Yamamoto, Masahiko; Taguchi, Shigeo

JAEA-Technology 2023-008, 34 Pages, 2023/06

JAEA-Technology-2023-008.pdf:1.92MB

Flush-out, by which nuclear materials in the Tokai Reprocessing Plant process are recovered, has been started in June 2022 as the first step of decommissioning. Flush-out consists of removal of spent fuel sheared powder, plutonium solution, uranium solution, and the other nuclear materials. Removal of spent fuel sheared powder has been completed in September 2022. During removal of spent fuel sheared powder, uranium concentration, plutonium concentration, acid concentration, radioactivity concentration, and solution density have been analyzed for process control. For nuclear material accountancy, uranium concentration, plutonium concentration, isotope ratio, and solution density have been analyzed. Analysis work including sample pretreatment before transportation to IAEA analytical facility for safeguards, and the other operations related to Flush-out such as calibration of analytical instruments, education, and training of operators are reported.

Journal Articles

Gyrotron development for high-power, long-pulse electron cyclotron heating and current drive at two frequencies in JT-60SA and its extension toward operation at three frequencies

Kobayashi, Takayuki; Moriyama, Shinichi; Yokokura, Kenji; Sawahata, Masayuki; Terakado, Masayuki; Hiranai, Shinichi; Wada, Kenji; Sato, Yoshikatsu; Hinata, Jun; Hoshino, Katsumichi; et al.

Nuclear Fusion, 55(6), p.063008_1 - 063008_8, 2015/06

 Times Cited Count:25 Percentile:77.04(Physics, Fluids & Plasmas)

A gyrotron enabling high-power, long-pulse oscillations at both 110 GHz and 138 GHz has been developed for electron cyclotron heating (ECH) and current drive (CD) in JT-60SA. Oscillations of 1 MW for 100 s have been demonstrated at both frequencies, for the first time as a gyrotron operating at two frequencies. The optimization of the anode voltage, or the electron pitch factor, using a triode gun was a key to obtain high power and high efficiency at two frequencies. It was also confirmed that the internal losses in the gyrotron were sufficiently low for expected long pulse operation at the higher power level of $$sim$$1.5 MW. Another important result is that an oscillation at 82 GHz, which enables to use fundamental harmonic waves in JT-60SA while the other two frequencies are used as second harmonics waves, was demonstrated up to 0.4 MW for 2 s. These results of the gyrotron development significantly contribute to enhancing operation regime of the ECH/CD system in JT-60SA.

Journal Articles

Development of a dual frequency (110/138 GHz) gyrotron for JT-60SA and its extension to an oscillation at 82 GHz

Kobayashi, Takayuki; Moriyama, Shinichi; Isayama, Akihiko; Sawahata, Masayuki; Terakado, Masayuki; Hiranai, Shinichi; Wada, Kenji; Sato, Yoshikatsu; Hinata, Jun; Yokokura, Kenji; et al.

EPJ Web of Conferences, 87, p.04008_1 - 04008_5, 2015/03

 Times Cited Count:5 Percentile:83.42(Physics, Fluids & Plasmas)

A dual-frequency gyrotron, which can generate 110 GHz and 138 GHz waves independently, is being developed in JAEA to enable electron cyclotron heating (ECH) and current drive (ECCD) in a wider range of plasma discharge conditions of JT-60SA. Operation for the gyrotron conditioning and parameter optimization toward 1 MW for 100 s, which is the target output power and pulse length for JT-60SA, is in progress without problems. Oscillations of 1 MW for 10 s and 0.51 MW for 198 s were obtained, so far, at both frequencies. In addition, an oscillation (0.3 MW for 20 ms) at 82 GHz was demonstrated as an additional frequency of the dual-frequency gyrotron which shows a possibility of the use of fundamental harmonic wave in JT-60SA.

Journal Articles

Genome analysis of high ethyl caproate producing sake yeasts generated by ion beam breeding

Masubuchi, Takashi*; Hyuga, Hirokazu*; Ueda, Ryoshiro; Hayashi, Hidenori*; Ikenaga, Hiroshi*; Sato, Katsuya; Ono, Yutaka

JAEA-Review 2014-050, JAEA Takasaki Annual Report 2013, P. 123, 2015/03

JAEA Reports

Development of instrument to measure transmission power density distribution using dielectric disk in millimeter waveguide

Yokokura, Kenji; Moriyama, Shinichi; Kobayashi, Takayuki; Hiranai, Shinichi; Sawahata, Masayuki; Terakado, Masayuki; Hinata, Jun; Wada, Kenji; Sato, Yoshikatsu; Hoshino, Katsumichi; et al.

JAEA-Technology 2014-002, 64 Pages, 2014/03

JAEA-Technology-2014-002.pdf:6.83MB

A new instrument has been developed to measure spatial distribution of power density and total power of the millimeter wave, by measuring temperature rise of dielectric material inserted in the waveguide. For a measurement, a dielectric disk with thermally insulated support is inserted into the few millimeters gap in the waveguide. The disk is heated by the millimeter wave pulse for 0.1$$sim$$0.2 s, and immediately after the pulse, it is pulled up and its temperature distribution is measured by an infrared camera to estimate the spatial power density distribution of the millimeter wave. In the other hand, total transmission power is estimated by the disk temperature reached equilibrium. In the measurement test, deformation of the power density distribution was successfully detected when the mirror angle was intentionally changed in the matching optics unit (MOU) at the waveguide input from the gyrotron. The test result shows that the instrument is effective for both adjustment of MOU without opening the vacuum boundary and to detect any abnormal transmission during operation of the ECH system. The test also shows high reliability of the instrument which stands with 1 MW high power transmission without any arcing or pressure rise in vacuum region. The instrument will be contributed to keep good condition of high power long pulse ECH system by detecting abnormal transmission in the waveguide in operation without open vacuum boundary.

Journal Articles

Development of a linear motion antenna for the JT-60SA ECRF system

Moriyama, Shinichi; Kobayashi, Takayuki; Isayama, Akihiko; Hoshino, Katsumichi; Suzuki, Sadaaki; Hiranai, Shinichi; Yokokura, Kenji; Sawahata, Masayuki; Terakado, Masayuki; Hinata, Jun; et al.

Fusion Engineering and Design, 88(6-8), p.935 - 939, 2013/10

 Times Cited Count:4 Percentile:32.11(Nuclear Science & Technology)

An antenna having a first mirror driven in the linear motion (LM) and a fixed second mirror was proposed for electron cyclotron range of frequency (ECRF) heating and current drive system, to minimize the risk of cooling-water-leakage. Basic mechanical feasibilities of the bellows covering the movable structures of the antenna were previously investigated using a mock-up. This time, a support structure of the shaft has been designed using a metallic sliding bearing with solid lubricant. The sliding bearing can support combination of linear and rotational motions while a ball bearing supports either linear or rotational motion. We have newly installed the sliding bearing into the mock-up. A vacuum pumping test has been carried out paying attention to the influence of the solid lubricant by mass analysis. To design the LM antenna for JT-60SA in detail, heating and current drive characteristics for typical experimental scenarios of JT-60SA has been investigated by calculation.

Journal Articles

Dual frequency ECRF system development for JT-60SA

Kobayashi, Takayuki; Isayama, Akihiko; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; Hiranai, Shinichi; Wada, Kenji; Sato, Yoshikatsu; Hinata, Jun; Yokokura, Kenji; et al.

Fusion Science and Technology, 63(1T), p.160 - 163, 2013/05

 Times Cited Count:7 Percentile:48.84(Nuclear Science & Technology)

A dual frequency electron cyclotron range of frequency system has been developed for JT-60SA, by which a second frequency (135 $$sim$$ 140 GHz) is generated in addition to the first frequency of 110 GHz. A development of a dual frequency gyrotron is a key to realize the dual frequency system. The second frequency was chosen to be 138 GHz from the above frequency range from the viewpoint of gyrotron design. In order to realize high-power ($$>$$ 1 MW) and long-pulse operation for both frequencies, we designed main components of the gyrotron (the diamond window, cavity resonator and quasi-optical mode converter). We found the optimum parameter set from the parameters of these components, which has discrete characteristics. It was confirmed that the output power higher than 1 MW is obtained for both frequencies as a result of numerical design. Based on the above design, a dual frequency gyrotron was newly fabricated. In the conditioning operation, an output power was obtained as we expected.

Journal Articles

Dual frequency gyrotron development for JT-60SA

Kobayashi, Takayuki; Isayama, Akihiko; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; Hiranai, Shinichi; Wada, Kenji; Sato, Yoshikatsu; Hinata, Jun; Yokokura, Kenji; et al.

Proceedings of 37th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz 2012) (USB Flash Drive), 2 Pages, 2012/09

A new dual frequency (110 GHz and 138 GHz) gyrotron development began for JT-60SA. An output power and efficiency higher than 1 MW and 30% with a peak heat load lower than 1.4 kW/cm$$^{2}$$ were obtained for both frequencies in calculation. High mode conversion efficiencies of the quasioptical mode converter (96.8% for 110 GHz and 98.3% for 138 GHz), which is higher than the previously developed 110 GHz long pulse gyrotron (96.5%), was obtained. The new gyrotron was fabricated and conditioning operation has been started from the middle of June 2012. The gyrotron output power of approximately 200 kW was obtained, so far, as we expected in the design of the gyrotron at low beam current of 10 A and low beam voltage of 75 kV.

Journal Articles

Recent results from the development of the electron cyclotron heating system for JT-60SA toward high-power long-pulse operations

Isayama, Akihiko; Kobayashi, Takayuki; Yokokura, Kenji; Shimono, Mitsugu; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; Hiranai, Shinichi; Wada, Kenji; Hinata, Jun; et al.

Plasma and Fusion Research (Internet), 7(Sp.1), p.2405029_1 - 2405029_5, 2012/05

no abstracts in English

Journal Articles

Progress in ECRF antenna development for JT-60SA

Kobayashi, Takayuki; Isayama, Akihiko; Hasegawa, Koichi; Suzuki, Sadaaki; Hiranai, Shinichi; Sato, Fumiaki; Wada, Kenji; Yokokura, Kenji; Shimono, Mitsugu; Sawahata, Masayuki; et al.

Fusion Engineering and Design, 86(6-8), p.763 - 767, 2011/10

 Times Cited Count:6 Percentile:44.02(Nuclear Science & Technology)

Progress of antenna development of the Electron Cyclotron Range of Frequency system for JT-60 SA is presented. Capability of pulse length of 100 s, which requires active cooling for mirrors, and flexibility of beam injection angles in both poloidal and toroidal directions are required for the antenna with high reliability. Mechanical and structural design works of the launcher (antenna and its support with steering structure) based on a linear motion antenna concept are in progress. The key component is a long-stroke bellows which enables to alter poloidal injection angle and a bellows which enables to alter toroidal injection angle. Using a newly fabricated mock-up of the steering structure, it was confirmed that the antenna was mechanically realized for poloidal and toroidal injection angle ranges of -10 to +45$$^{circ}$$ and -15 to +15$$^{circ}$$, respectively. Those angles are consistent with angles required in JT-60SA. The results of thermal and structural analyses are also presented.

Journal Articles

Progress of high-power and long-pulse ECRF system development in JT-60

Kobayashi, Takayuki; Isayama, Akihiko; Yokokura, Kenji; Shimono, Mitsugu; Hasegawa, Koichi; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; Hiranai, Shinichi; Sato, Fumiaki; et al.

Nuclear Fusion, 51(10), p.103037_1 - 103037_10, 2011/10

 Times Cited Count:19 Percentile:62.10(Physics, Fluids & Plasmas)

A new gyrotron operation technique to increase oscillation efficiency was developed on the JT 60 ECRF system. The electron pitch factor was optimized by controlling anode voltage within 0.1 s after the start of the operation. By applying this technique, the gyrotron output power of 1.5 MW for 4 s was recorded, for the first time. The reduced collector heat load at 1.5 MW operations was reduced by 20% and it will be acceptable for longer pulse operation. A new gyrotron with an improved mode converter was developed in order to demonstrate reduction of the stray radiation which had limited the pulse length. The stray radiation was reduced to 1/3 of that of the original gyrotron. A conditioning operation of the improved gyrotron is proceeding up to 31 s at 1 MW. These progresses significantly contribute to enhancing the high power and long pulse capability of the ECRF system toward JT 60SA.

Journal Articles

Development of the long-pulse ECRF system for JT-60SA

Kobayashi, Takayuki; Isayama, Akihiko; Fasel, D.*; Yokokura, Kenji; Shimono, Mitsugu; Hasegawa, Koichi; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; Hiranai, Shinichi; et al.

Journal of Plasma and Fusion Research SERIES, Vol.9, p.363 - 368, 2010/08

Improvements are required for expanding the pulse length of the JT-60 ECRF system (5s) for JT-60SA (100s). Newly developed power supplies will be fabricated and installed by EU. The conditioning operation of an improved gyrotron equipping a newly designed mode convertor has been started. The mode convertor will reduce heat flux on the internal components and therefore expected to enable long pulse operation at 1 MW. Pre-programmed and/or feedback control of the heater current and anode voltage, which was successfully demonstrated in JT-60U, will be key techniques because the beam current decreases during a shot. The evacuated transmission lines have a capability of 1 MW per line. Since maintenance of the components in the vacuum vessel is difficult, a linear motion antenna concept was proposed to reduce risks of water leakage and fault of the driving mechanism in the vacuum vessel. The detailed design and the low power test of a mock-up antenna have been started.

Oral presentation

Design and development of electron cyclotron heating and current drive system for JT-60SA

Kobayashi, Takayuki; Isayama, Akihiko; Hoshino, Katsumichi; Yokokura, Kenji; Shimono, Mitsugu; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; Hiranai, Shinichi; Wada, Kenji; et al.

no journal, , 

Design and development of high-power long-pulse electron cyclotron heating and current drive system for JT-60SA have been progressed. High power transmission test using newly developed components with a waveguide inner diameter of 60.3 mm was carried out. A conditioning operation was progressed to 5 s with an output power of 0.5 MW, so far, within a few weeks without significant trouble. The other progress was made to develop the dual frequency system with an additional frequency of 137.6 GHz in order to enhance operation regime. Output power higher than 1 MW with oscillation efficiency much higher than 30% was obtained for the design of a dual frequency gyrotron for both 110 GHz and 137.6 GHz.

Oral presentation

Operation experience and development status of ECRF system in JT-60U

Moriyama, Shinichi; Kobayashi, Takayuki; Isayama, Akihiko; Yokokura, Kenji; Shimono, Mitsugu; Hasegawa, Koichi; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; Hiranai, Shinichi; et al.

no journal, , 

Full specification of 4 MW for 5s was achieved by simultaneous operation of 4 gyrotrons, and 3 MW was injected to the JT-60U plasma by the completion of experiments in August 2008. In the inspection of the antenna after the operation, there were no large damages but the color of the mirror surfaces were slightly changed and some evidences of arcing were found. In the statistical analysis of operation, the rate of successful shots to the plasma was higher than 85% in the last 3 years. Development of long-pulse gyrotron with improved mode converter is on going and the conditioning was started in the end of 2008 aiming at 1 MW, 100s for JT-60SA. It was confirmed that the diffraction loss was remarkably decreased and the pulse length reached 1 MW 17s so far. A new operation technique of active anode voltage control was developed to obtain high efficiency, and the pulse length for 1.5 MW oscillation was extended from 1s to 4s.

Oral presentation

Development on ECRF system for JT-60SA

Moriyama, Shinichi; Kobayashi, Takayuki; Isayama, Akihiko; Yokokura, Kenji; Hoshino, Katsumichi; Shimono, Mitsugu; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; Hiranai, Shinichi; et al.

no journal, , 

Development and design of ECRF system are being carried on toward JT-60SA. In spite of the huge earthquake on March 11th, damage on the system was small, and we restart the gyrotron operation after 2 months of careful inspection and test. The diffraction loss in the gyrotron was kept low and the temperature of the DC break cooling water, which limited the pulse length, was saturated at about half of that before the improvement of the mode convertor. The pulse length reached 31 s at 1 MW and 99 s at 0.3 MW. In JT-60SA, ECRF of about 130-140 GHz would make possible central heating/current drive at BT = 2.25 T. From this point of view, development of dual frequency gyrotron was started. In calculation, oscillation conditions with efficiency of 0.4 were obtained for TE22,8 mode (110 GHz) and TE27,10 mode (137.6 GHz). Fabrication of the gyrotron has just been started. The high power test will be started in the next fiscal year.

Oral presentation

Design and test of launcher and transmission line for JT-60SA ECRF system

Kobayashi, Takayuki; Isayama, Akihiko; Suzuki, Sadaaki; Hiranai, Shinichi; Wada, Kenji; Hinata, Jun; Sato, Yoshikatsu; Yokokura, Kenji; Hoshino, Katsumichi; Moriyama, Shinichi

no journal, , 

Design and test of launcher and transmission line for JT-60SA electron cyclotron range of frequency (ECRF) system have been carried out. Spatial profile of temperature rise of 31.75 mm waveguide components, which was used in the previous JT-60, was measured for high-power and long-pulse transmission. It was clarified that improvements of cooling efficiency or change in design is required for achieving 1 MW, 100 s transmission, which is required in JT-60SA. Thus 60.3 mm waveguide components was newly installed. In the preliminary test of the new transmission line, unexpected arcing and increase in vacuum pressure was not observed, and the system worked as expected. As for the launcher, a preliminary layout of the launcher and support was improved in order to keep acceptable distance from systems around the ECRF launcher. Moreover, a mock-up of an improved support structure of the driving shaft using solid lubricants was fabricated in order to improve reliability of the structure.

Oral presentation

Design study of antenna and transmission line of JT-60SA electron cyclotron heating system using 3D-CAD

Wada, Kenji; Kobayashi, Takayuki; Isayama, Akihiko; Hasegawa, Koichi; Sato, Fumiaki; Yokokura, Kenji; Suzuki, Sadaaki; Shibayama, Minoru; Hiranai, Shinichi; Shimono, Mitsugu; et al.

no journal, , 

no abstracts in English

Oral presentation

Development of ECRF system toward steady-state operation in JT 60SA

Isayama, Akihiko; Kobayashi, Takayuki; Moriyama, Shinichi; Sawahata, Masayuki; Suzuki, Sadaaki; Yokokura, Kenji; Shimono, Mitsugu; Hasegawa, Koichi; Terakado, Masayuki; Hiranai, Shinichi; et al.

no journal, , 

no abstracts in English

Oral presentation

Progress on electron cyclotron heating antenna design for JT-60SA

Kobayashi, Takayuki; Isayama, Akihiko; Suzuki, Sadaaki; Hiranai, Shinichi; Wada, Kenji; Sato, Yoshikatsu; Hinata, Jun; Yokokura, Kenji; Hoshino, Katsumichi; Moriyama, Shinichi; et al.

no journal, , 

Capabilities of the transmission power of 0.8 MW and pulse duration of 100 s, and two dimensional beam steering both in poloidal and toroidal directions are required for electron cyclotron (EC) heating antenna in JT-60SA. An antenna based on a linear-motion concept has been designed. Recently, rf profiles for various poloidal/toroidal beam angles were measured using mock-up mirrors and a low power millimeter wave source. It was confirmed that the beam direction and profile of the antenna were agree with the numerical design. Moreover, some candidates of the support structure of the steering shaft were considered and one of them, which used a small sliding bearing, was tested by a mock-up. In this test, smooth movement in vacuum condition was confirmed. An extention of the operation regime of the system by means of dual frequency EC waves has been studied. Results of evaluation of the antenna steering range for this purpose is also presented.

Oral presentation

Development of ECRF heating and current drive system for JT-60SA

Moriyama, Shinichi; Kobayashi, Takayuki; Isayama, Akihiko; Hoshino, Katsumichi; Yokokura, Kenji; Shimono, Mitsugu; Hasegawa, Koichi; Sawahata, Masayuki; Suzuki, Sadaaki; Terakado, Masayuki; et al.

no journal, , 

no abstracts in English

45 (Records 1-20 displayed on this page)