Umino, Yoshinori; Kato, Keisuke; Tanigawa, Masafumi; Kobayashi, Daisuke; Obu, Tomoyuki; Kimura, Yuichi*; Nemoto, Ryo*; Tajiri, Kazuma*
Nihon Hozen Gakkai Dai-19-Kai Gakujutsu Koenkai Yoshishu, p.33 - 36, 2023/08
In the basic laboratory of the Plutonium Conversion Development Facility in Tokai Reprocessing Plant, tests had been conducted to obtain effective data for manufacturing mixed plutonium and uranium oxide powder by irradiating a mixture of plutonium and uranium solution with microwaves. The test has already been completed, and we are currently dismantling and removing equipment. In this paper, techniques related to equipment renewal, dismantling and removal works inside the glove-box are discussed.
Kobayashi, Daisuke; Yamamoto, Masahiko; Nishida, Naoki; Miyoshi, Ryuta; Nemoto, Ryo*; Hayashi, Hiroyuki*; Kato, Keisuke; Nishino, Saki; Kuno, Takehiko; Kitao, Takahiko; et al.
Nihon Hozen Gakkai Dai-18-Kai Gakujutsu Koenkai Yoshishu, p.237 - 240, 2022/07
All gloves attached to glove-box in Tokai Reprocessing Plant have a fixed expiration date and have to be replaced every 4-year. However, degrees of glove deterioration are different depending on its usage environment (frequency, chemicals, radiation, etc.), because of rubber products. Therefore, physical properties such as tensile strength, elongation, hardness of gloves are measured, and the life-time of gloves are estimated. As a result, gloves without any defects in its appearance have enough physical property for acceptance criteria of new glove. The extrapolated physical property of glove is sufficiently larger than the reported values of damaged glove. No deterioration in physical properties of gloves, that are periodically replaced without any defects in its appearance, is observed and the usable life-time of the glove is estimated to be 8 years.