Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 55

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

$$^{149}$$Sm synchrotron-radiation-based M$"{o}$ssbauer and $$mu^+$$SR studies of Sm$$_3$$Ru$$_4$$Ge$$_{13}$$

Tsutsui, Satoshi; Ito, Takashi; Nakamura, Jin*; Yoshida, Mio*; Kobayashi, Yoshio*; Yoda, Yoshitaka*; Nakamura, Jumpei*; Koda, Akihiro*; Higashinaka, Ryuji*; Aoki, Dai*; et al.

Interactions (Internet), 245(1), p.55_1 - 55_9, 2024/12

Journal Articles

Research on improvement of HTGR core power-density, 4; Feasibility study for a reactor core

Okita, Shoichiro; Mizuta, Naoki; Takamatsu, Kuniyoshi; Goto, Minoru; Yoshida, Katsumi*; Nishimura, Yosuke*; Okamoto, Koji*

Proceedings of 30th International Conference on Nuclear Engineering (ICONE30) (Internet), 10 Pages, 2023/05

Journal Articles

Analyses of $$H$$*(10) dose rates measured in environment contaminated by radioactive caesium; Correction of directional dependence of scintillation detectors

Tsuda, Shuichi; Tanigaki, Minoru*; Yoshida, Tadayoshi; Okumura, Ryo*; Saito, Kimiaki

Radiation Protection Dosimetry, 193(3-4), p.228 - 236, 2021/03

AA2020-0760.pdf:0.87MB

 Times Cited Count:6 Percentile:49.03(Environmental Sciences)

Environmental dose rate monitoring has been performed with various scintillation detectors since the Fukushima Dai-ichi Nuclear Power Plant accident. Gamma-rays from caesium isotopes deposited in soil enter radiation detectors in any direction, but directional dependence of the detectors used for dose rate measurements are not always uniform and the dose rates vary even if measurement takes place at the same place. To investigate the influence of crystal configurations on dose rate, dose rate measurements using several scintillation detectors with different crystal configurations were conducted. By measuring pulse height spectra and multiplying them with spectrum - dose conversion operators (G(E) function), dose rates were deduced and compared. It was found that the dose rates varied within approximately 25% among six detectors. To reduce the differences, the dose rate using G(E) functions determined in rotational geometry were obtained and applied instead. The revised dose rates agreed with one another within uncertainties, but this was not the case of scintillation detector with flat crystal shape, and it means this method could not compensate its strong directional dependence. These experimental results reveal that detectors with superior directional characteristics should be used for environmental dose rate measurement since the compensation of directional dependence using a G(E) function determined in rotational geometry is not always available.

Journal Articles

Morphological reproductive characteristics of testes and fertilization capacity of cryopreserved sperm after the Fukushima accident in raccoon (${it Procyon lotor}$)

Komatsu, Kazuki*; Iwasaki, Tsugumi*; Murata, Kosuke*; Yamashiro, Hideaki*; Goh, V. S. T.*; Nakayama, Ryo*; Fujishima, Yohei*; Ono, Takumi*; Kino, Yasushi*; Shimizu, Yoshinaka*; et al.

Reproduction in Domestic Animals, 56(3), p.484 - 497, 2021/03

 Times Cited Count:17 Percentile:86.86(Agriculture, Dairy & Animal Science)

We have established an archive system of livestock and wild animals from the surrounding ex-evacuation zone. Wildlife within the alert zone have been exposed to low-dose-rate (LDR) radiation for a long and continuous time. In this study, we analysed the morphological characteristics of the testes and in vitro fertilization (IVF) capacity of cryopreserved sperm of raccoons from the ex-evacuation zone of the FDNPP accident. This study revealed that the chronic and LDR radiation exposure associated with the FDNPP accident had no adverse effect on the reproductive characteristics and functions of male raccoons.

Journal Articles

Conceptual study on parasitic low-energy RI beam production with in-flight separator BigRIPS and the first stopping examination for high-energy RI beams in the parasitic gas cell

Sonoda, Tetsu*; Katayama, Ichiro*; Wada, Michiharu*; Iimura, Hideki; Sonnenschein, V.*; Iimura, Shun*; Takamine, Aiko*; Rosenbusch, M.*; Kojima, Takao*; Ahn, D. S.*; et al.

Progress of Theoretical and Experimental Physics (Internet), 2019(11), p.113D02_1 - 113D02_12, 2019/11

AA2019-0315.pdf:1.37MB

 Times Cited Count:1 Percentile:9.23(Physics, Multidisciplinary)

An in-flight separator, BigRIPS, at RIBF in RIKEN provides each experiment with specific nuclides separated from many nuclides produced by projectile fragmentation or in-flight fission. In this process, nuclides other than separated ones are discarded on the slits in BigRIPS, although they include many nuclides interested from the view point of nuclear structure. In order to extract these nuclides for parasitic experiments, we are developing a method using laser ion-source (PALIS). A test experiment with $$^{78}$$Se beam from RIBF has been performed by using a gas cell set in BigRIPS. Unstable nuclides around $$^{67}$$Se were stopped in the gas cell in accordance with a calculation using LISE code. The stopping efficiency has been estimated to be about 30%. As a next step, we will establish the technique for extracting reaction products from the gas cell.

Journal Articles

In situ X-ray observations of pure-copper layer formation with blue direct diode lasers

Sato, Yuji*; Tsukamoto, Masahiro*; Shobu, Takahisa; Funada, Yoshinori*; Yamashita, Yorihiro*; Hara, Takahiro*; Sengoku, Masanori*; Sakon, Yu*; Okubo, Tomomasa*; Yoshida, Minoru*; et al.

Applied Surface Science, 480, p.861 - 867, 2019/06

 Times Cited Count:46 Percentile:85.02(Chemistry, Physical)

Journal Articles

New precise measurements of muonium hyperfine structure at J-PARC MUSE

Strasser, P.*; Abe, Mitsushi*; Aoki, Masaharu*; Choi, S.*; Fukao, Yoshinori*; Higashi, Yoshitaka*; Higuchi, Takashi*; Iinuma, Hiromi*; Ikedo, Yutaka*; Ishida, Katsuhiko*; et al.

EPJ Web of Conferences, 198, p.00003_1 - 00003_8, 2019/01

 Times Cited Count:18 Percentile:98.64(Quantum Science & Technology)

Journal Articles

Review of the performance of a car-borne survey system, KURAMA-II, used to measure the dose rate after the Fukushima Dai-ichi Nuclear Power Plant accident

Tsuda, Shuichi; Tanigaki, Minoru*; Yoshida, Tadayoshi; Saito, Kimiaki

Hoshasen, 44(3), p.109 - 118, 2018/11

JAEA has started to perform dose rate monitoring using a car-borne survey system KURAMA to rapidly produce the dose rate mappings of the deposited radionuclides in the environment after the Fukushima Dai-ichi Nuclear Power Plant accident. KURAMA is a car-borne survey system developed by Kyoto University to perform dose rate monitoring in a wide area in detail with rapidity. By improving KURAMA with continuous dose rate monitoring, the 2nd generation of KURAMA (KURAMA-II) succeeded in downsizing, durability and automated transmission of data so that enable detailed dose rate mapping in wide area in shorter period of time. This paper reports the radiation characteristics and the simulation analysis of KURAMA-II on the special issue of Hoshasen, the journal of Ionization Radiation Division in the Japan society of applied physics.

Journal Articles

Dependence of dose rate measurement in the environment on crystal configuration of scintillation detectors

Tsuda, Shuichi; Tanigaki, Minoru*; Yoshida, Tadayoshi; Okumura, Ryo*; Saito, Kimiaki

Nihon Genshiryoku Gakkai Wabun Rombunshi, 17(1), p.11 - 17, 2018/03

Environmental dose rate monitoring has been performed using scintillation detectors since the Fukushima Dai-ichi Nuclear Power Plant accident happened. After the accident, various scintillation detectors with directional dependence are used in the measurement, though detectors with superior directional dependence are needed because photons come from various direction in the environment. To investigate the influence of crystal configurations on indicated values of dose rates, pulse height spectra were measured using scintillation-based detectors with different crystal configurations and ambient dose rates were obtained using a spectrum - dose conversion operator (G(E) function). It is found that the dose rate for a rectangular-parallelepiped crystal is $$sim$$ 40% than that for a cylindrical one at the maximum. However, the values agreed within 10% among all the detectors irrespective of the crystal shapes, using G(E) functions determined in a rotational irradiation geometry.

Journal Articles

Elucidation of the morphology of the hydrocarbon multi-block copolymer electrolyte membranes for proton exchange fuel cells

Zhao, Y.; Yoshida, Miru*; Oshima, Tatsuya*; Koizumi, Satoshi*; Rikukawa, Masahiro*; Szekely, N.*; Radulescu, A.*; Richter, D.*

Polymer, 86, p.157 - 167, 2016/03

 Times Cited Count:13 Percentile:38.91(Polymer Science)

Journal Articles

Model magnet development of D1 beam separation dipole for the HL-LHC upgrade

Nakamoto, Tatsushi*; Sugano, Michinaka*; Xu, Q.*; Kawamata, Hiroshi*; Enomoto, Shun*; Higashi, Norio*; Idesaki, Akira; Iio, Masami*; Ikemoto, Yukio*; Iwasaki, Ruri*; et al.

IEEE Transactions on Applied Superconductivity, 25(3), p.4000505_1 - 4000505_5, 2015/06

 Times Cited Count:1 Percentile:7.75(Engineering, Electrical & Electronic)

Recently, development of superconducting magnet system with high radiation resistance has been demanded for application in accelerator facilities such as CERN LHC. In order to realize superconducting magnet system with high radiation resistance, it is necessary to develop electrical insulator with high radiation resistance because the electrical insulator is made of organic materials whose radiation resistance is inferior to that of inorganic materials. We developed a glass fiber reinforced plastic with bismaleimide-triazine resin. The developed material showed excellent radiation resistance; the material evolved gases of 5$$times$$10 $$^{-5}$$mol/g and maintained flexural strength of 640MPa (90% of initial value).

Journal Articles

Measurements and evaluations of air dose rates around Fukushima, 4; Practical aspects of air dose rate measurements in the environment

Tsuda, Shuichi; Yoshida, Tadayoshi; Ando, Masaki; Matsuda, Norihiro; Mikami, Satoshi; Tanigaki, Minoru*; Okumura, Ryo*; Takamiya, Koichi*; Sato, Nobuhiro*; Seki, Akiyuki; et al.

Radioisotopes, 64(4), p.275 - 289, 2015/04

This article provides practically useful information on air dose rate measurements in the environments. The basic requirements for the accurate measurements are described giving actual data. The characteristics and some measured results are shown for reliable methods which are widely used in the environmental radiation measurements. Further, information is given on internet sites where air dose rates and related data obtained by official organizations can be browsed.

Journal Articles

Measurement of air dose rates over a wide area around the Fukushima Dai-ichi Nuclear Power Plant through a series of car-borne surveys

Ando, Masaki; Nakahara, Yukio; Tsuda, Shuichi; Yoshida, Tadayoshi; Matsuda, Norihiro; Takahashi, Fumiaki; Mikami, Satoshi; Kinouchi, Nobuyuki; Sato, Tetsuro*; Tanigaki, Minoru*; et al.

Journal of Environmental Radioactivity, 139, p.266 - 280, 2015/01

 Times Cited Count:58 Percentile:81.55(Environmental Sciences)

A series of car-borne surveys using the KURAMA and KURAMA-II systems was conducted in a wide area in eastern Japan from June 2011 to December 2012 to evaluate the distribution of air dose rates around the Fukushima Dai-ichi Nuclear Power Plant, and to determine the time-dependent trend of decrease in air dose rates. An automated data processing system was established, which enables analyses of large amounts of data obtained with the use of about 100 units of the measurement system in a short time. The initial data for studying the migration status of radioactive cesium was obtained in the first survey, followed by the other car-borne surveys having wider measurement ranges. Comparing the measured air dose rates obtained in each survey, it was found that the decreasing trend of air dose rates measured through car-borne surveys was larger than that expected from the physical decay of radioactive cesium and that measured using NaI (Tl) survey meters around the road.

JAEA Reports

Construction of a car-borne survey system for measurement of dose rates in air; KURAMA-II, and its application

Tsuda, Shuichi; Yoshida, Tadayoshi; Nakahara, Yukio; Sato, Tetsuro; Seki, Akiyuki; Matsuda, Norihiro; Ando, Masaki; Takemiya, Hiroshi; Tanigaki, Minoru*; Takamiya, Koichi*; et al.

JAEA-Technology 2013-037, 54 Pages, 2013/10

JAEA-Technology-2013-037.pdf:4.94MB

JAEA has been performing dose rate mapping in air using a car-borne survey system KURAMA-II. The KURAMA system is a GPS-aided mobile radiation monitoring system that has been newly developed by Kyoto University Research Reactor Institute in response to the nuclear disaster. The KURAMA system is composed of an energy-compensated scintillation survey meter for measuring dose rate, electric device for controlling both the dose rates and the position data from a GPS module, a computer server for processing and analyzing data from KURAMA, and client PCs for providing for end users. The KURAMA-II has been improved in small-packaging, durability, and automated data transmission. In consequence, dose rate mapping in wide area has become possible in shorter period of time. This report describes the construction of KURAMA-II, its application and a suggestion of how to manage a large number of KURAMA-II.

Journal Articles

PFG-NMR and SANS studies in cation exchange membranes based on sulfonated polyphenylene multiblock copolymers

Yoshida, Miru*; Zhao, Y.; Fujita, Masahiro*; Ohira, Akihiro*; Takeoka, Yuko*; Koizumi, Satoshi*; Rikukawa, Masahiro*

ECS Transactions, 50(2), p.1045 - 1053, 2012/10

Journal Articles

27th report of ITPA topical group meeting

Osakabe, Masaki*; Shinohara, Koji; Toi, Kazuo*; Todo, Yasushi*; Hamamatsu, Kiyotaka; Murakami, Sadayoshi*; Yamamoto, Satoshi*; Idomura, Yasuhiro; Sakamoto, Yoshiteru; Tanaka, Kenji*; et al.

Purazuma, Kaku Yugo Gakkai-Shi, 85(12), p.839 - 842, 2009/12

no abstracts in English

Journal Articles

Dynamics of ion internal transport barrier in LHD heliotron and JT-60U tokamak plasmas

Ida, Katsumi*; Sakamoto, Yoshiteru; Yoshinuma, Mikiro*; Takenaga, Hidenobu; Nagaoka, Kenichi*; Hayashi, Nobuhiko; Oyama, Naoyuki; Osakabe, Masaki*; Yokoyama, Masayuki*; Funaba, Hisamichi*; et al.

Nuclear Fusion, 49(9), p.095024_1 - 095024_9, 2009/09

 Times Cited Count:32 Percentile:72.48(Physics, Fluids & Plasmas)

Dynamics of ion internal transport barrier (ITB) formation and impurity transport both in the Large Helical Device (LHD) heliotron and JT-60U tokamak are described. Significant differences between heliotron and tokamak plasmas are observed. The location of the ITB moves outward during the ITB formation regardless of the sign of magnetic shear in JT-60U and the ITB becomes more localized in the plasma with negative magnetic shear. In LHD, the low Te/Ti ratio ($$<$$ 1) of the target plasma for the high power heating is found to be necessary condition to achieve the ITB plasma and the ITB location tends to expand outward or inward depending on the condition of the target plasmas. Associated with the formation of ITB, the carbon density tends to be peaked due to inward convection in JT-60U, while the carbon density becomes hollow due to outward convection in LHD. The outward convection observed in LHD contradicts the prediction by neoclassical theory.

Journal Articles

Transient absorption of a cation radical of pyrene induced by heavy ion beam pulses

Kondo, Takafumi*; Yang, J.*; Kan, Koichi*; Yoshida, Yoichi*; Shibata, Hiromi*; Taguchi, Mitsumasa; Kojima, Takuji

JAEA-Review 2007-060, JAEA Takasaki Annual Report 2006, P. 160, 2008/03

no abstracts in English

Journal Articles

Advanced diagnostics for burning plasma experiments

Sasao, Mamiko*; Yamada, Hiroshi*; Baba, Mamoru*; Kondoh, Takashi; Peterson, B. J.*; Kawahata, Kazuo*; Mase, Atsushi*; Yoshikawa, Masayuki*; Azechi, Hiroshi*; Toi, Kazuo*; et al.

Fusion Science and Technology, 51(2T), p.40 - 45, 2007/02

 Times Cited Count:0 Percentile:0.00(Nuclear Science & Technology)

Several unexplored physics issues will be studied in burning plasma experiments, planned on ITER in the near future. To carry out these studies, it is essential to develop novel diagnostic systems, such as fusion product measurement systems and high-resolution, high-reliability profile measurement of various plasma parameters. Scientific research on "Advanced Diagnostics for Burning Plasma Experiment" was assigned as a priority area by MEXT in 2004, and more than 20 studies are currently underway under this program. The feasibility of several new diagnostic concepts applicable to ITER is examined and diagnostic components for these systems are now under development.

Journal Articles

Development of the heavy ion beam pulse radiolysis

Kondo, Takafumi*; Yang, J.*; Kan, Koichi*; Yoshida, Yoichi*; Shibata, Hiromi*; Taguchi, Mitsumasa; Kojima, Takuji

JAEA-Review 2006-042, JAEA Takasaki Annual Report 2005, P. 141, 2007/02

no abstracts in English

55 (Records 1-20 displayed on this page)