Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 131

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Design and actual performance of J-PARC 3 GeV rapid cycling synchrotron for high-intensity operation

Yamamoto, Kazami; Kinsho, Michikazu; Hayashi, Naoki; Saha, P. K.; Tamura, Fumihiko; Yamamoto, Masanobu; Tani, Norio; Takayanagi, Tomohiro; Kamiya, Junichiro; Shobuda, Yoshihiro; et al.

Journal of Nuclear Science and Technology, 59(9), p.1174 - 1205, 2022/09

 Times Cited Count:5 Percentile:81.82(Nuclear Science & Technology)

In the Japan Proton Accelerator Research Complex, the purpose of the 3 GeV rapid cycling synchrotron (RCS) is to accelerate a 1 MW, high-intensity proton beam. To achieve beam operation at a repetition rate of 25 Hz at high intensities, the RCS was elaborately designed. After starting the RCS operation, we carefully verified the validity of its design and made certain improvements to establish a reliable operation at higher power as possible. Consequently, we demonstrated beam operation at a high power, namely, 1 MW. We then summarized the design, actual performance, and improvements of the RCS to achieve a 1 MW beam.

Journal Articles

Sodium-cooled Fast Reactors

Ohshima, Hiroyuki; Morishita, Masaki*; Aizawa, Kosuke; Ando, Masanori; Ashida, Takashi; Chikazawa, Yoshitaka; Doda, Norihiro; Enuma, Yasuhiro; Ezure, Toshiki; Fukano, Yoshitaka; et al.

Sodium-cooled Fast Reactors; JSME Series in Thermal and Nuclear Power Generation, Vol.3, 631 Pages, 2022/07

This book is a collection of the past experience of design, construction, and operation of two reactors, the latest knowledge and technology for SFR designs, and the future prospects of SFR development in Japan. It is intended to provide the perspective and the relevant knowledge to enable readers to become more familiar with SFR technology.

Journal Articles

The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye

Yokoyama, Sumi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; Ono, Koji*; et al.

Journal of Radiation Protection and Research, 47(1), p.1 - 7, 2022/03

Background: In Japan, new regulations that revise the dose limit for the lens of the eye (the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulatory Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods: The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set to not exceed the dose limit for the lens. Results and Discussion: In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 questions. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion: With the development of guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimise radiation protection.

Journal Articles

Magnetic Bragg peak enhancement under ultrasound injection

Shamoto, Shinichi*; Akatsu, Mitsuhiro*; Matsuura, Masato*; Kawamura, Seiko; Harii, Kazuya*; Ono, Masao*; Chang, L.-J.*; Ito, Takashi; Nemoto, Yuichi*; Ieda, Junichi

Physical Review Research (Internet), 4(1), p.013245_1 - 013245_7, 2022/03

Ultrasound injection effect on a magnetic Bragg peak of yttrium iron garnet has been studied by quasielastic neutron scattering. The magnetic Bragg peak is vastly enhanced with decreasing temperature. The energy width increases proportionally to the square root of the sample temperature increase induced by the ultrasound injection. Because the magnetic Bragg peak is enhanced by the lattice vibration, the enhancement is expected to relate to the spin-lattice coupling closely. An observed sharp drop above 100 K in the longitudinal mode suggests the degradation of the spin-lattice coupling. It is consistent with the decline of spin Seebeck effect with increasing temperature above 100 K, proving the degradation mechanism by the spin-lattice coupling.

Journal Articles

Development of guidelines on radiation protection for the lens of the eye in Japan

Yokoyama, Sumi*; Iwai, Satoshi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; et al.

Proceedings of 15th International Congress of the International Radiation Protection Association (IRPA-15) (Internet), 8 Pages, 2022/00

Journal Articles

Japanese population dose from natural radiation

Omori, Yasutaka*; Hosoda, Masahiro*; Takahashi, Fumiaki; Sanada, Tetsuya*; Hirao, Shigekazu*; Ono, Koji*; Furukawa, Masahide*

Journal of Radiological Protection, 40(3), p.R99 - R140, 2020/09

 Times Cited Count:23 Percentile:76.17(Environmental Sciences)

UNSCEAR and the Nuclear Safety Research Association report the annual effective doses from cosmic rays, terrestrial radiation, inhalation and ingestion from natural sources. In this study, radiation doses from natural radiation sources in Japan were reviewed with the latest knowledge and data. Total annual effective dose from cosmic-ray exposure can be evaluated as 0.29 mSv. The annual effective dose from external exposure to terrestrial radiation for Japanese population can be evaluated as 0.33 mSv using the data of nationwide survey by the National Institute of Radiological Sciences. The Japan Chemical Analysis Center (JCAC) performed the nationwide radon survey using a unified method for radon measurements in indoor, outdoor and workplace. The annual effective dose for radon inhalation was estimated using a current dose conversion factor, and the values were estimated to be 0.50 mSv. The annual effective dose from thoron was reported as 0.09 mSv by UNSCEAR and then the annual effective dose from inhalation can be described as 0.59 mSv. According to the report of large scale survey of foodstuff by JCAC, the effective dose from main radionuclides due to dietary intake can be evaluated to be 0.99 mSv. Finally, Japanese population dose from natural radiation can be assessed as 2.2 mSv which is near to the world average value of 2.4 mSv.

Journal Articles

Emergent spin-1 Haldane gap and ferroelectricity in a frustrated spin-$$frac{1}{2}$$ ladder

Ueda, Hiroshi*; Onoda, Shigeki*; Yamaguchi, Yasuhiro*; Kimura, Tsuyoshi*; Yoshizawa, Daichi*; Morioka, Toshiaki*; Hagiwara, Masayuki*; Hagihara, Masato*; Soda, Minoru*; Masuda, Takatsugu*; et al.

Physical Review B, 101(14), p.140408_1 - 140408_6, 2020/04

 Times Cited Count:4 Percentile:25.35(Materials Science, Multidisciplinary)

Journal Articles

Development of a structured overset Navier-Stokes solver with a moving grid and full multigrid method

Ohashi, Kunihide*; Hino, Takanori*; Kobayashi, Hiroshi*; Onodera, Naoyuki; Sakamoto, Nobuaki*

Journal of Marine Science and Technology, 24(3), p.884 - 901, 2019/09

 Times Cited Count:17 Percentile:77.42(Engineering, Marine)

An unsteady Reynolds averaged Navier-Stokes solver with a structured overset grid method has been developed. Velocity pressure coupling is achieved using an artificial compressibility approach, spatial discretization is based on a FVM. Body motions are considered using the grid deformation technique and grid velocities in the convective term. The full multigrid (FMG) method is applied to obtain fast convergence. The cell flag on a coarse grid level is determined using the cell flag on a fine grid level. In the coarse and fine grid level calculations at the FMG stage, the data are interpolated until the finest grid level is achieved at an overset update interval. Then, the data are updated based on the overset relations at the finest grid level and then transferred to a coarser grid level. The computations for flows around a hull form, including an unsteady simulation with regular waves, are demonstrated.

Journal Articles

Imaging measurement of neutron attenuation by small-angle neutron scattering using soller collimator

Oba, Yojiro; Shinohara, Takenao; Sato, Hirotaka*; Onodera, Yohei*; Hiroi, Kosuke; Su, Y. H.; Sugiyama, Masaaki*

Journal of the Physical Society of Japan, 87(9), p.094004_1 - 094004_5, 2018/09

 Times Cited Count:1 Percentile:11.74(Physics, Multidisciplinary)

no abstracts in English

Journal Articles

Numerical analysis of organ doses delivered during computed tomography examinations using Japanese adult phantoms with the WAZA-ARI dosimetry system

Takahashi, Fumiaki; Sato, Kaoru; Endo, Akira; Ono, Koji*; Ban, Nobuhiko*; Hasegawa, Takayuki*; Katsunuma, Yasushi*; Yoshitake, Takayasu*; Kai, Michiaki*

Health Physics, 109(2), p.104 - 112, 2015/08

 Times Cited Count:8 Percentile:55.62(Environmental Sciences)

A dosimetry system, named WAZA-ARI, is developed to assess accurately radiation doses to persons from Computed Tomography (CT) examination patients in Japan. Organ doses were prepared to application to dose calculations in WAZA-ARI by numerical analyses using average adult Japanese human models with the Particle and Heavy Ion Transport code System (PHITS). Experimental studies clarified the radiation configuration on the table for some multi-detector row CT (MDCT) devices. Then, a source model in PHITS could specifically take into account for emissions of X-ray in each MDCT device based on the experiment results. Numerical analyses with PHITS revealed a concordance of organ doses with human body size. The organ doses by the JM phantoms were compared with data obtained using previously developed systems. In addition, the dose calculation in WAZA-ARI were verified with previously reported results by realistic NUBAS phantoms and radiation dose measurement using a physical Japanese model. The results implied that analyses using the Japanese phantoms and PHITS including source models can appropriately give organ dose data with consideration of the MDCT device and physiques of typical Japanese adults.

Journal Articles

WAZA-ARI; A Dose assessment system for patients in CT scan

Sato, Kaoru; Takahashi, Fumiaki; Endo, Akira; Ono, Koji*; Hasegawa, Takayuki*; Katsunuma, Yasushi*; Yoshitake, Takayasu*; Ban, Nobuhiko*; Kai, Michiaki*

RIST News, (58), p.25 - 32, 2015/01

The Japan Atomic Energy Agency (JAEA) are now developing WAZA-ARI for improvement of management of exposure doses due to CT examination under the joint research with the Oita University of Nursing and Health Sciences. The trial version of WAZA-ARI has been released on 21 December 2012. In trial version, users can perform dose assessment by using organ dose database based on the average adult Japanese male (JM-103) and female (JF-103) voxel phantoms and a 4 years old female voxel phantom (UFF4). The homepage of WAZA-ARI has been accessed over 1000 times per month and 28421 times by the end of September 2014. We are developing WAZA-ARI version 2 as the extension version of dose calculation functions of WAZA-ARI. WAZA-ARI version 2 will be released by the end of March 2015. In WAZA-ARI version 2. Users can upload dose calculation results to WAZA-ARI version 2 server, and utilize improvement of the dose management of patients and the optimization of CT scan conditions.

Journal Articles

Ultracentrifuge experiment on AgI super-ionic conductor

Ono, Masao; Okayasu, Satoru; Iguchi, Yusuke*; Esaka, Fumitaka; Bagum, R.*; Haruki, Rie; Mashimo, Tsutomu*

Transactions of the Japan Society for Aeronautical and Space Sciences, Aerospace Technology Japan (Internet), 12(ists29), p.Tq_1 - Tq_3, 2014/04

We had realized the composition gradient of elements or isotopes in some binary alloys or single element by solid-state centrifugation. While, it might difficult to realize graded structure of elements in binary ionic crystal by centrifugation as it strongly keeps their stoichiometry. However, isotope fractionation in binary ionic crystal by centrifugation might be expected as the self-diffusion of ions occurs. We have planed the ultracentrifuge experiments on $$alpha$$-AgI superionic conductor to investigate the isotope effect in binary ionic crystal under a strong centrifugal acceleration field. $$alpha$$-AgI superionic conductor is suitable for the confirmation experiment as it is an intrinsic ionic crystal and Ag ions have high diffusivity. For the first stage, we have experimentally searched the experimental conditions of magnitude of centrifugal acceleration and temperature that ensure the experiment without decomposition. It is confirmed that the combination of experimental conditions of up to 6.1$$times$$10$$^{5}$$ g, 350$$^{circ}$$C, 24h ensure the experiment without decomposition at least.

Journal Articles

Enhanced charge collection by single ion strike in AlGaN/GaN HEMTs

Onoda, Shinobu; Hasuike, Atsushi*; Nabeshima, Yoshiaki*; Sasaki, Hajime*; Yajima, Kotaro*; Sato, Shinichiro; Oshima, Takeshi

IEEE Transactions on Nuclear Science, 60(6), p.4446 - 4450, 2013/12

 Times Cited Count:43 Percentile:95.22(Engineering, Electrical & Electronic)

no abstracts in English

Journal Articles

Research of the radiation tolerance in space environment of general electronic devices

Maeda, Takahiro*; Kakimi, Yukitaka*; Akashi, Kenji*; Oshima, Takeshi; Onoda, Shinobu

Proceedings of 10th International Workshop on Radiation Effects on Semiconductor Devices for Space Applications (RASEDA-10) (Internet), p.27 - 28, 2012/12

Journal Articles

MgO-based inert matrix fuels for a minor actinides recycling in a fast reactor cycle

Miwa, Shuhei; Osaka, Masahiko; Usuki, Toshiyuki; Sato, Isamu; Tanaka, Kosuke; Hirosawa, Takashi; Yoshimochi, Hiroshi; Onose, Shoji

Proceedings of International Conference on Toward and Over the Fukushima Daiichi Accident (GLOBAL 2011) (CD-ROM), 8 Pages, 2011/12

A new fast reactor (FR) cycle concept was previously proposed that incorporates MgO-based inert matrix fuels (IMFs) containing minor actinides harmonious with the existing FR cycle technologies. A basic study of MgO-based IMFs was made regarding their fabrication, characterization and reprocessing in terms of applicability to existing FR cycle technology. It was concluded from these basic investigations of MgO-based IMFs that the existing FR cycle technologies can be applied to those for MgO-based IMFs, and the basic technologies of MgO-based IMFs containing minor actinides harmonious with the existing FR cycle technologies were established.

Journal Articles

Removal of cesium using cobalt-ferrocyanide-impregnated polymer-chain-grafted fibers

Ishihara, Ryo*; Fujiwara, Kunio*; Harayama, Takato*; Okamura, Yusuke*; Uchiyama, Shoichiro*; Sugiyama, Mai*; Someya, Takaaki*; Amakai, Wataru*; Umino, Satoshi*; Ono, Tsubasa*; et al.

Journal of Nuclear Science and Technology, 48(10), p.1281 - 1284, 2011/10

AA2011-0190.pdf:0.45MB

 Times Cited Count:44 Percentile:94.57(Nuclear Science & Technology)

Journal Articles

Effects of human model configuration in Monte Carlo calculations for organ doses from CT examinations

Takahashi, Fumiaki; Sato, Kaoru; Endo, Akira; Ono, Koji*; Yoshitake, Takayasu*; Hasegawa, Takayuki*; Katsunuma, Yasushi*; Ban, Nobuhiko*; Kai, Michiaki*

Progress in Nuclear Science and Technology (Internet), 2, p.153 - 159, 2011/10

Computed Tomography (CT) is one of the most useful tools for medical diagnosis, and is becoming a major source of medical exposure in developed countries. Appropriate radiation protection in CT examinations is emphasized by international organizations, such as the International Atomic Energy Agency (IAEA), because the patients receive higher radiation doses than in conventional radiography. Medical staffs can acquire dose information on the conditions of some CT examinations with available dosimetry systems, which had been already developed. These systems utilize datasets of organ and tissue doses, which were derived with Monte Carlo calculations. Methods in computational analyses, however, have been improved, since these calculations had been performed. Then, our new dosimetry system for CT examination, WAZA-ARI, is being developed to estimate radiation dose based upon the state-of-art numerical analyses. Our analysis adopts Particle and Heavy Ion Transport code System (PHITS) coupled with a voxel-type phantom, JM phantom, for the organ dose calculation. PHITS has advantageous to define the model of photon emission from X-ray tube in a CT device for radiation transport calculations. The physique and mass of organs for JM phantom are similar to those for average Japanese male adults. Since the goal of WAZA-ARI is to provide dosimetric information of arbitrary patient, it is important to evaluate uncertainty due to different configurations in human bodies between JM phantom and individual patients. For this purpose, the organ doses are calculated and compared for different human models; another Japanese male adult voxel phantom and the ICRP reference voxel phantom, which is constructed on the basis of Caucasian data.

Journal Articles

Development of a web-based CT dose calculator; WAZA-ARI

Ban, Nobuhiko*; Takahashi, Fumiaki; Sato, Kaoru; Endo, Akira; Ono, Koji*; Hasegawa, Takayuki*; Yoshitake, Takayasu*; Katsunuma, Yasushi*; Kai, Michiaki*

Radiation Protection Dosimetry, 147(1-2), p.333 - 337, 2011/09

 Times Cited Count:27 Percentile:87.8(Environmental Sciences)

A web-system of WAZA-ARI is being developed to assess radiation dose to a patient in a Computed Tomography (CT) examination. The databases of organ doses for WAZA-ARI were derived by the Japanese adult Male phantom (JM phantom) combined with the Particle and Heavy Ion Transport code System, PHITS. In the Monte Carlo simulation, the phantoms were irradiated with a 5 mm-thick fan-shaped photon beam, which was moved every 5 mm along the body axis from the upper leg to the top of head. The attenuation by the beam-shaping filter (bow-tie filter) was also taken into account here. The MIRD-type phantom was also applied to the calculations. The MIRD phantom sometimes showed step changes for organ doses, while smoother curves were obtained for JM phantom. The dose data by JM phantom were incorporated into the WAZA-ARI system, which has been implemented on a Linux server. With regard to the system implementation, the system has achieved a high degree of flexibility without commercial software.

Journal Articles

WAZA-ARI; Computational dosimetry system for X-ray CT examinations, 1; Radiation transport calculation for organ and tissue doses evaluation using JM phantom

Takahashi, Fumiaki; Sato, Kaoru; Endo, Akira; Ono, Koji*; Yoshitake, Takayasu*; Hasegawa, Takayuki*; Katsunuma, Yasushi*; Ban, Nobuhiko*; Kai, Michiaki*

Radiation Protection Dosimetry, 146(1-3), p.241 - 243, 2011/07

 Times Cited Count:20 Percentile:81.23(Environmental Sciences)

A web-system of WAZA-ARI is being developed to assess radiation dose to a patient in a Computed Tomography (CT) examination. WAZA-ARI utilizes a set of organ and tissue doses in a database for the dose assessment, according to the given resources with a consideration of the examination condition. The organ and tissue doses in the database have been derived with the Particle and Heavy Ion Transport code System, PHITS. Modeling of the patient was a significant issue in the radiation transport calculation. JM phantom, whose height (171 cm) and weight (65 kg) are near to those averaged over Japanese male adults, was incorporated to PHITS as a human model. Since JM phantom consisted of about 1 mm$$^{3}$$ size voxel, the shapes could be realistically reproduced even for small organs such as thyroid, adrenals. Masses of most organs could be also adjusted to the averaged values of Japanese male adults. In addition, our calculations introduced a new phantom without arms based upon JM phantom, because the patient usually puts arms toward the head direction in a torso examination. Some of organ doses calculated by JM phantom were compared with results, which were derived with a MIRD-type phantom. Differences could be seen in some organ doses between the phantoms, if photon attenuations in a shaping (Bow-tie) filter were taken into account to a source model in PHITS.

Journal Articles

WAZA-ARI; Computational dosimetry system for X-ray CT examinations, 2; Development of web-based system

Ban, Nobuhiko*; Takahashi, Fumiaki; Ono, Koji*; Hasegawa, Takayuki*; Yoshitake, Takayasu*; Katsunuma, Yasushi*; Sato, Kaoru; Endo, Akira; Kai, Michiaki*

Radiation Protection Dosimetry, 146(1-3), p.244 - 247, 2011/07

 Times Cited Count:20 Percentile:81.23(Environmental Sciences)

We are developing a web-based system, WAZA-ARI, for the dose calculation of patients undergoing X-ray CT examinations. Tissue doses were calculated in a Japanese adult male phantom (JM phantom) using a Monte Carlo code, PHITS, and the normalized dose coefficient data are stored as XML files. The system is implemented in Java on a Linux server running Apache Tomcat, which is accessed via a web browser over a network. Users are requested to choose scanning options and to input parameters in the data entry screen. The corresponding dose data are called upon input, and they are summed over the scan range specified by the user to estimate unit tissue doses. Tissue doses are computed based on the radiographic exposure (mAs), the beam pitch and air kerma at the beam center on the axis of rotation. Users can also use their own air kerma, CTDI vol and DLP values for the dose computation instead of the default setting. Although the dose coefficients are prepared for only limited CT scanner models currently, our system has achieved high usability and easy maintenance without commercial software. Possibility of further expansion for the practical application is also discussed.

131 (Records 1-20 displayed on this page)