Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Investigation of strand bending in the He-inlet during reaction heat treatment for ITER TF Coils

Hemmi, Tsutomu; Matsui, Kunihiro; Kajitani, Hideki; Okuno, Kiyoshi; Koizumi, Norikiyo; Ishimi, Akihiro; Katsuyama, Kozo

IEEE Transactions on Applied Superconductivity, 24(3), p.4802704_1 - 4802704_4, 2014/06

 Times Cited Count:1 Percentile:9.39(Engineering, Electrical & Electronic)

Japan Atomic Energy Agency (JAEA), as Japan Domestic Agency, has responsibility to procure nine ITER Toroidal Field (TF) coils. The TF coil winding consists of a Nb$$_{3}$$Sn Cable-In-Conduit conductor, a pair of joints and a He-inlet. The current capacity of 68 kA is required at the magnetic field of 7 T around the He-inlet region in the TF coil winding. During reaction heat-treatment, the compressive residual strain in Nb$$_{3}$$Sn cable is induced by the difference in the thermal expansion coefficients between the Nb$$_{3}$$Sn cable and stainless steel jacket. The strands bending in the Nb$$_{3}$$Sn cable of the He-inlet is anticipated since there is the compressive residual strain and a gap between the Nb$$_{3}$$Sn cable and the He-inlet to introduce SHE flow. If the strand is bent, the variation of mechanical behaviors, such as the elongation of He-inlet during the reaction heat-treatment and the thermally induced residual strain on the jacket around the He-inlet, are expected. To investigate the strands bending in the Nb$$_{3}$$Sn cable of the He-inlet, the following items are performed; (1) elongation measurement during reaction heat-treatment, (2) residual longitudinal strain measurement using strain gauges by sample cuttings, (3) nondestructive inspection on the cable and strands using high resolution X-ray CT, Detail of test results and investigation of the strands bending in the Nb$$_{3}$$Sn cable of the He-inlet are reported and discussed.

Journal Articles

Effect of salt-containing filter paper attached to osmotic membrane

Sano, Kenji*; Yamada, Arisa*; Matsui, Akihiro*; Tsuji, Hideyuki*; Hasegawa, Shin; Sawada, Shinichi; Maekawa, Yasunari

Desalination, 324, p.34 - 36, 2013/09

 Times Cited Count:3 Percentile:14.09(Engineering, Chemical)

Anchored osmotic pressure inducer was examined. Salt-containing filter paper attached to an osmotic membrane increased the water flux to more than 10% at 1 MPa. The salt-containing filter paper was fabricated via graft polymerization of acrylic acid onto a filter paper followed by alkaline treatment. The filter paper was characterized by thermo gravimetric analysis (TGA), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), scanning electronic microscopy-energy dispersive X-ray spectrometry(SEM-EDS).

Journal Articles

Engineering design of cryoplant for ITER

; Kato, Takashi; Matsui, Kunihiro; Tsuji, Hiroshi; ; ; Yoshida, Kiyoshi; V.Kalinin*; M.Wykes*; ; et al.

Proc. of 16th Int. Cryogenic Engineering Conf. /Int. Cryogenic Materials Conf., 0, p.131 - 134, 1996/00

no abstracts in English

3 (Records 1-3 displayed on this page)
  • 1