Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Lee, D. H.*; Dodo, Taku; Haga, Katsuhiro; Harada, Masahide; Hasegawa, Shoichi; Kasugai, Yoshimi; Kinoshita, Hidetaka; Masuda, Shiho; Meigo, Shinichiro; Sakai, Kenji; et al.
Nuclear Instruments and Methods in Physics Research A, 1072, p.170216_1 - 170216_6, 2025/03
Times Cited Count:2 Percentile:97.11(Instruments & Instrumentation)Okuizumi, Mao*; Auton, C. J.*; Endo, Shunsuke; Fujioka, Hiroyuki*; Hirota, Katsuya*; Ino, Takashi*; Ishizaki, Kohei*; Kimura, Atsushi; Kitaguchi, Masaaki*; Koga, Jun*; et al.
Physical Review C, 111(3), p.034611_1 - 034611_6, 2025/03
Times Cited Count:0 Percentile:0.00(Physics, Nuclear)Dodo, Taku; Haga, Katsuhiro; Harada, Masahide; Hasegawa, Shoichi; Kasugai, Yoshimi; Kinoshita, Hidetaka; Masuda, Shiho; Meigo, Shinichiro; Sakai, Kenji; Suzuya, Kentaro; et al.
Progress of Theoretical and Experimental Physics (Internet), 2025(2), p.023H02_1 - 023H02_8, 2025/02
Times Cited Count:0 Percentile:0.00(Physics, Multidisciplinary)Marzec, E.*; Dodo, Taku; Haga, Katsuhiro; Harada, Masahide; Hasegawa, Shoichi; Kasugai, Yoshimi; Kinoshita, Hidetaka; Masuda, Shiho; Meigo, Shinichiro; Sakai, Kenji; et al.
Physical Review Letters, 134, p.081801_1 - 081801_9, 2025/00
Times Cited Count:1 Percentile:0.00(Physics, Multidisciplinary)Lee, D. H.*; Dodo, Taku; Haga, Katsuhiro; Harada, Masahide; Hasegawa, Shoichi; Kasugai, Yoshimi; Kinoshita, Hidetaka; Masuda, Shiho; Meigo, Shinichiro; Sakai, Kenji; et al.
European Physical Journal C, 84, p.409_1 - 409_6, 2024/04
Times Cited Count:1 Percentile:32.29(Physics, Particles & Fields)Okudaira, Takuya*; Nakabe, Rintaro*; Auton, C. J.*; Endo, Shunsuke; Fujioka, Hiroyuki*; Gudkov, V.*; Ide, Ikuo*; Ino, Takashi*; Ishikado, Motoyuki*; Kambara, Wataru*; et al.
Physical Review C, 109(4), p.044606_1 - 044606_9, 2024/04
Times Cited Count:2 Percentile:70.47(Physics, Nuclear)Nakabe, Rintaro*; Auton, C. J.*; Endo, Shunsuke; Fujioka, Hiroyuki*; Gudkov, V.*; Hirota, Katsuya*; Ide, Ikuo*; Ino, Takashi*; Ishikado, Motoyuki*; Kambara, Wataru*; et al.
Physical Review C, 109(4), p.L041602_1 - L041602_4, 2024/04
Times Cited Count:1 Percentile:15.24(Physics, Nuclear)Kamiya, Junichiro; Oi, Motoki; Kobayashi, Fuminori; Sakai, Kenji; Yamada, Ippei
Vacuum and Surface Science, 67(4), p.186 - 191, 2024/04
This report describes the usage, specification, troubles and countermeasures of dry pumps in the Japan Proton Accelerator Research Complex (J-PARC). In J-PARC, while dry scroll pumps (DSP) are widely used, many are being replaced with roots pumps due to frequent maintenance and troubles of DSP. Some of the facilities use roots pumps with special specifications, such as radiation-resistant specifications, separate power supply, and with diaphragm type, etc. Although some problems have occurred with both DSPs and roots pumps, they have been addressed by revising maintenance methods and improving parts, contributing to stable operation for users.
Shin, C. D.*; Dodo, Taku; Haga, Katsuhiro; Harada, Masahide; Hasegawa, Shoichi; Kasugai, Yoshimi; Kinoshita, Hidetaka; Masuda, Shiho; Meigo, Shinichiro; Sakai, Kenji; et al.
Journal of Instrumentation (Internet), 18(12), p.T12001_1 - T12001_9, 2023/12
Times Cited Count:0 Percentile:0.00(Instruments & Instrumentation)Okudaira, Takuya*; Tani, Yuika*; Endo, Shunsuke; Doskow, J.*; Fujioka, Hiroyuki*; Hirota, Katsuya*; Kameda, Kento*; Kimura, Atsushi; Kitaguchi, Masaaki*; Luxnat, M.*; et al.
Physical Review C, 107(5), p.054602_1 - 054602_7, 2023/05
Times Cited Count:5 Percentile:72.52(Physics, Nuclear)no abstracts in English
Endo, Shunsuke; Okudaira, Takuya*; Abe, Ryota*; Fujioka, Hiroyuki*; Hirota, Katsuya*; Kimura, Atsushi; Kitaguchi, Masaaki*; Oku, Takayuki; Sakai, Kenji; Shima, Tatsushi*; et al.
Physical Review C, 106(6), p.064601_1 - 064601_7, 2022/12
Times Cited Count:7 Percentile:70.25(Physics, Nuclear)no abstracts in English
Koga, Jun*; Takada, Shusuke*; Endo, Shunsuke; Fujioka, Hiroyuki*; Hirota, Katsuya*; Ishizaki, Kohei*; Kimura, Atsushi; Kitaguchi, Masaaki*; Niinomi, Yudai*; Okudaira, Takuya*; et al.
Physical Review C, 105(5), p.054615_1 - 054615_5, 2022/05
Times Cited Count:7 Percentile:70.25(Physics, Nuclear)no abstracts in English
Ajimura, Shuhei*; Haga, Katsuhiro; Harada, Masahide; Hasegawa, Shoichi; Kasugai, Yoshimi; Kinoshita, Hidetaka; Masuda, Shiho; Meigo, Shinichiro; Sakai, Kenji; Suzuya, Kentaro; et al.
Nuclear Instruments and Methods in Physics Research A, 1014, p.165742_1 - 165742_15, 2021/10
Times Cited Count:25 Percentile:94.76(Instruments & Instrumentation)Okudaira, Takuya*; Endo, Shunsuke; Fujioka, Hiroyuki*; Hirota, Katsuya*; Ishizaki, Kohei*; Kimura, Atsushi; Kitaguchi, Masaaki*; Koga, Jun*; Niinomi, Yudai*; Sakai, Kenji; et al.
Physical Review C, 104(1), p.014601_1 - 014601_6, 2021/07
Times Cited Count:7 Percentile:62.30(Physics, Nuclear)Park, J. S.*; Harada, Masahide; Hasegawa, Shoichi; Kasugai, Yoshimi; Meigo, Shinichiro; Sakai, Kenji; Suzuya, Kentaro; 55 of others*
Progress of Theoretical and Experimental Physics (Internet), 2021(6), p.063C01_1 - 063C01_12, 2021/06
Times Cited Count:1 Percentile:11.32(Physics, Multidisciplinary)Harada, Masahide; Sekijima, Mitsuaki*; Morikawa, Noriyuki*; Masuda, Shiho; Kinoshita, Hidetaka; Sakai, Kenji; Kai, Tetsuya; Kasugai, Yoshimi; Muto, Giichi*; Suzuki, Akio*; et al.
JPS Conference Proceedings (Internet), 33, p.011099_1 - 011099_6, 2021/03
In MLF at J-PARC, a unified mercury radioactivity monitor (UHAM) is installed to find an indication of failure of the mercury target and loop system by detecting radioactive materials leaked from the system with a -ray energy analysis with Germanium semi-conductor detectors (Ge detectors). It is composed of three units of sampling port and radiation monitors: (1) HAM for interstitial helium gas layer between the mercury vessel and surrounding water shroud of the mercury target, (2) CAM for atmosphere in the hot cell where the target loop is operated and (3) VAM for helium gas in the helium vessel where the target vessel is installed. Once any leakages of radioactive materials are detected, an alarm signal is issued immediately to the accelerator control system to stop beam operation. Software and hardware have been upgraded yearly. For example, two Ge detectors are used for HAM for redundancy, NaI Scintillation detectors are also used as supplemental for the Ge detector to keep availability of the system for high counting rate event. In April 2015, the UHAM activated when a small water coolant leakage from the water shroud of the mercury target occurred. VAM detected an abnormal increase of the counting rate in the helium vessel. It was also indicated that the measured radioactive nuclides were generated from the activation of the coolant (water) in the water shroud and not from the mercury.
Sakai, Kenji; Oku, Takayuki; Okudaira, Takuya; Kai, Tetsuya; Harada, Masahide; Hiroi, Kosuke; Hayashida, Hirotoshi*; Kakurai, Kazuhisa*; Shimizu, Hirohiko*; Hirota, Katsuya*; et al.
JPS Conference Proceedings (Internet), 33, p.011116_1 - 011116_6, 2021/03
In neutron fundamental physics, study of correlation term of a neutron spin
and a target nuclear spin
is important because
term interferes to parity non-conserving (PNC) and time reversal non-conserving terms. For this study, a xenon (Xe) is an interesting nucleus because it has been observed an enhancement of PNC effect around neutron resonance peaks, and polarizes up to
by using a spin exchange optical pumping (SEOP) method. We would plan to develop a polarized Xe gas target with a compact in-situ SEOP system, and to study
term by utilizing epithermal neutron beams supplied from a high intense pulsed spallation neutron source. As the first step, we attempted to measure neutron polarizing ability caused by
term at a 9.6 eV s-wave resonance peak of
Xe at BL10 in MLF, by detecting change
of ratio between neutron transmissions with the polarized and unpolarized Xe target. After demonstrating that our apparatus could detect small change (
) of neutron transmissions caused by Doppler broadening effect, a signified value of
has been obtained as preliminary results. For analyzing the obtained
in detail, we are improving our nuclear magnetic resonance and electron paramagnetic resonance systems for evaluating Xe polarization independently of neutron beams.
Sakai, Kenji; Oi, Motoki; Haga, Katsuhiro; Kai, Tetsuya; Nakatani, Takeshi; Kobayashi, Yasuo*; Watanabe, Akihiko*
JPS Conference Proceedings (Internet), 33, p.011151_1 - 011151_6, 2021/03
For safely and efficiently operating a spallation neutron source and a muon target, a general control system (GCS) operates within Materials and Life Science Experimental Facility (MLF), GCS administers operation processes and interlocks of many instruments for various operation statuses. It consists of several subsystems such as an integral control system (ICS), interlock systems (ILS), shared servers, network system, and timing distribution system (TDS). Although GCS is an independent system that controls the target stations, it works closely with the control systems of other facilities in J-PARC. Since the first beam injection in 2008, GCS has operated stably without any serious troubles after modification based on commissioning for operation and control. Then, significant improvements in GCS such as upgrade of ICS by changing its framework software and function enhancement of ILS were proceeded until 2015, in considering sustainable long-term operation and maintenance. In recent years, many instruments in GCS have replaced due to end of production and support of them. In this way, many modifications have been proceeded in the entire GCS after start of beam operation. Under these situation, it is important to comprehend upgrade history and present status of GCS in order to decide its upgrade plan for the coming ten years. This report will mention upgrade history, present status and future agenda of GCS.
Sakai, Kenji; Oi, Motoki; Teshigawara, Makoto; Naoe, Takashi; Haga, Katsuhiro; Watanabe, Akihiko*
Journal of Neutron Research, 22(2-3), p.337 - 343, 2020/10
For operating a spallation neutron source and a muon target safely and efficiently, a general control system (GCS) operates within Materials and Life Science Experimental Facility (MLF). GCS administers operation and interlock processes of many instruments under various operation status. Since the first beam injection in 2008, it has operated stably without any serious troubles for more than ten years. GCS has a data storage server storing operational data on status around target stations. It has functioned well to detect and investigate unusual situations by checking data in this server. For continuing stable operation of MLF in future, however, introduction of abnormality sign determination system (ASDS) will be necessary for picking up potential abnormalities of target stations caused by radiation damages, time-related deterioration and so on. It will judge abnormalities from slight state transitions of target stations based on analysis with various operational data throughout proton beams, target stations, and secondary beams during long-term operations. This report mentions present status of GCS, conceptual design of ASDS, and installation of an integral data storage server which can deal with various data for ASDS integrally.
Okudaira, Takuya; Oku, Takayuki; Ino, Takashi*; Hayashida, Hirotoshi*; Kira, Hiroshi*; Sakai, Kenji; Hiroi, Kosuke; Takahashi, Shingo*; Aizawa, Kazuya; Endo, Hitoshi*; et al.
Nuclear Instruments and Methods in Physics Research A, 977, p.164301_1 - 164301_8, 2020/10
Times Cited Count:21 Percentile:89.31(Instruments & Instrumentation)