検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 10 件中 1件目~10件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Rabi-oscillation spectroscopy of the hyperfine structure of muonium atoms

西村 昇一郎*; 鳥居 寛之*; 深尾 祥紀*; 伊藤 孝; 岩崎 雅彦*; 神田 聡太郎*; 川越 清以*; Kawall, D.*; 河村 成肇*; 黒澤 宣之*; et al.

Physical Review A, 104(2), p.L020801_1 - L020801_6, 2021/08

 被引用回数:13 パーセンタイル:83.13(Optics)

As a method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as conventional spectroscopy with a frequency sweep. Furthermore, the data under different conditions can be treated in a unified manner, allowing more efficient measurements for systems consisting of a limited number of short-lived particles produced by accelerators such as muons. We have developed a fitting function that takes into account the spatial distribution of muonium and the spatial distribution of the microwave intensity to apply this method to ground-state muonium hyperfine structure measurements at zero field. It was applied to the actual measurement data, and the resonance frequencies were determined under various conditions. The result of our analysis gives $$nu_{rm HFS}$$ = 4 463 301.61 $$pm$$ 0.71 kHz.

論文

New precise measurements of muonium hyperfine structure at J-PARC MUSE

Strasser, P.*; 阿部 充志*; 青木 正治*; Choi, S.*; 深尾 祥紀*; 東 芳隆*; 樋口 嵩*; 飯沼 裕美*; 池戸 豊*; 石田 勝彦*; et al.

EPJ Web of Conferences, 198, p.00003_1 - 00003_8, 2019/01

 被引用回数:13 パーセンタイル:99.06(Quantum Science & Technology)

High precision measurements of the ground state hyperfine structure (HFS) of muonium is a stringent tool for testing bound-state quantum electrodynamics (QED) theory, determining fundamental constants of the muon magnetic moment and mass, and searches for new physics. Muonium is the most suitable system to test QED because both theoretical and experimental values can be precisely determined. Previous measurements were performed decades ago at LAMPF with uncertainties mostly dominated by statistical errors. At the J-PARC Muon Science Facility (MUSE), the MuSEUM collaboration is planning complementary measurements of muonium HFS both at zero and high magnetic field. The new high-intensity muon beam that will soon be available at H-Line will provide an opportunity to improve the precision of these measurements by one order of magnitude. An overview of the different aspects of these new muonium HFS measurements, the current status of the preparation for high-field measurements, and the latest results at zero field are presented.

論文

New precise measurement of muonium hyperfine structure interval at J-PARC

上野 恭裕*; 青木 正治*; 深尾 祥紀*; 東 芳隆*; 樋口 嵩*; 飯沼 裕美*; 池戸 豊*; 石田 勝彦*; 伊藤 孝; 岩崎 雅彦*; et al.

Hyperfine Interactions, 238(1), p.14_1 - 14_6, 2017/11

 被引用回数:3 パーセンタイル:86.59(Physics, Atomic, Molecular & Chemical)

MuSEUM is an international collaboration aiming at a new precise measurement of the muonium hyperfine structure at J-PARC (Japan Proton Accelerator Research Complex). Utilizing its intense pulsed muon beam, we expect a ten-fold improvement for both measurements at high magnetic field and zero magnetic field. We have developed a sophisticated monitoring system, including a beam profile monitor to measure the 3D distribution of muonium atoms to suppress the systematic uncertainty.

論文

New muonium HFS measurements at J-PARC/MUSE

Strasser, P.*; 青木 正治*; 深尾 祥紀*; 東 芳隆*; 樋口 嵩*; 飯沼 裕美*; 池戸 豊*; 石田 勝彦*; 伊藤 孝; 岩崎 雅彦*; et al.

Hyperfine Interactions, 237(1), p.124_1 - 124_9, 2016/12

 被引用回数:7 パーセンタイル:90.97(Physics, Atomic, Molecular & Chemical)

At the Muon Science Facility (MUSE) of J-PARC (Japan Proton Accelerator Research Complex), the MuSEUM collaboration is planning new measurements of the ground state hyperfine structure (HFS) of muonium both at zero field and at high magnetic field. The previous measurements were performed both at LAMPF (Los Alamos Meson Physics Facility) with experimental uncertainties mostly dominated by statistical errors. The new high intensity muon beam that will soon be available at MUSE H-Line will provide an opportunity to improve the precision of these measurements by one order of magnitude. An overview of the different aspects of these new muonium HFS measurements, the current status of the preparation, and the results of a first commissioning test experiment at zero field are presented.

論文

Online full two-dimensional imaging of pulsed muon beams at J-PARC MUSE using a gated image intensifier

伊藤 孝; 豊田 晃久*; 髭本 亘; 田島 美典*; 松田 恭幸*; 下村 浩一郎*

Nuclear Instruments and Methods in Physics Research A, 754, p.1 - 9, 2014/08

 被引用回数:7 パーセンタイル:48.36(Instruments & Instrumentation)

A new muon beam profile monitor (MBPM) was developed to diagnose pulsed muon beams in J-PARC MUSE, mainly composed of a scintillation screen, a gated image intensifier (II), and a cooled CCD camera. The MBPM was designed to be compact so that it could be inserted into the bore of the $$mu$$SR spectrometer in the D1 area and used concurrently. The spatial resolution of the MBPM was evaluated to be in the range from one to two line-pair/mm, depending on II gain. Such high-resolution muon beam profiles were obtained online for a positive muon beam with a kinetic energy of $$sim$$ 4 MeV. The contribution from decay positrons was significantly reduced owing to II gating. The linearity of the MBPM was evaluated on the bases of the number of decay positrons monitored by the $$mu$$SR spectrometer. A linear response within five percent deviations was confirmed over more than two orders of magnitude. In addition, 3D imaging capability, use in vacuum, and immunity against moderate magnetic fields were demonstrated.

論文

Birth of an intense pulsed muon source, J-PARC MUSE

三宅 康博*; 下村 浩一郎*; 河村 成肇*; Strasser, P.*; 牧村 俊助*; 幸田 章宏*; 藤森 寛*; 中原 一隆*; 門野 良典*; 加藤 峯夫*; et al.

Physica B; Condensed Matter, 404(5-7), p.957 - 961, 2009/04

 被引用回数:12 パーセンタイル:47.84(Physics, Condensed Matter)

ミュオン科学実験施設(MUSE)はJ-PARCの実験施設の一つである、MUSEは中性子とミュオン利用の実験施設である物質生命科学実験施設(MLF)の中にある。MLFの建屋建設は2004年にはじまり、2006年度末に完了した。われわれはそこにビームライン機器の設置を行っており、最初のミュオンビームが2008年の秋に発生する予定である。

論文

Status of J-PARC muon science facility at the year of 2005

三宅 康博*; 西山 樟生*; 河村 成肇*; 牧村 俊助*; Strasser, P.*; 下村 浩一郎*; Beveridge, J. L.*; 門野 良典*; 福地 光一*; 佐藤 伸彦*; et al.

Physica B; Condensed Matter, 374-375, p.484 - 487, 2006/03

 被引用回数:6 パーセンタイル:31.27(Physics, Condensed Matter)

物質生命科学実験施設の建屋の建設は2004年度の初めに開始された。2008年に加速器とビーム輸送系のコミッショニングが行われた後、2009年にはミュオンのユーザー利用が開始される。この論文ではJ-PARCミュオン科学実験施設建設の現状について述べる。

論文

J-PARC muon science facility with use of 3GeV proton beam

三宅 康博*; 河村 成肇*; 牧村 俊助*; Strasser, P.*; 下村 浩一郎*; 西山 樟生*; Beveridge, J. L.*; 門野 良典*; 佐藤 伸彦*; 福地 光一*; et al.

Nuclear Physics B; Proceedings Supplements, 149, p.393 - 395, 2005/12

J-PARCミュオン施設は物質生命科学実験施設の中に位置する。中性子標的の手前に置かれたミュオン標的から得られるミュオンを用いた研究が行われる。このJ-PARCミュオン科学施設の概要を報告する。

口頭

Development of a high-resolution beam imaging system for pulsed muon beams

伊藤 孝; 豊田 晃久*; 髭本 亘; 田島 美典*; 松田 恭幸*; 下村 浩一郎*

no journal, , 

パルスミュオンビームを用いる実験では、大量のミュオンがその寿命よりも短い時間内に標的にやってくるため、ミュオン1個毎の$$mu-e$$崩壊を識別することは不可能である。このため、標的外に止まったミュオンの崩壊イベントを識別してリジェクトするという、連続状ビームに対してよく用いられる方法は使えない。よって、パルスミュオンビームによる実験では、ビームを標的に対し効率よく照射することが求められる。これを実現するためには、標的周辺の詳細なビームプロファイルをオンラインで測定し、ビームチューニングにフィードバックする必要がある。このためのビームプロファイルモニタには、高空間分解能とリアルタイム性が要求される。我々は、J-PARCミュオン科学実験施設の$$mu$$SR分光器との共存を考慮して、新たにコンパクトなミュオンビームプロファイルモニタを開発した。ミュオンビームがシンチレータに入射した際に発生したシンチレーション光を撮像することによりビームプロファイルを得る。イメージインテンシファイアを用いて光学像を増強することにより、明瞭なビームプロファイルが数十秒という短時間で得られた。

口頭

イメージインテンシファイアを用いたミュオンビームプロファイルモニタの開発

伊藤 孝; 豊田 晃久*; 髭本 亘; 田島 美典*; 松田 恭幸*; 下村 浩一郎*

no journal, , 

パルスミュオンビームを用いる実験では、大量のミュオンがその寿命よりも短い時間内に標的にやってくるため、ミュオン1個毎の$$mu e$$崩壊を識別することは不可能である。このため、標的外に止まったミュオンの崩壊イベントを識別してリジェクトするという、連続状ビームに対してよく用いられる方法は使えない。よって、パルスミュオンビームによる実験では、ビームを標的に対し効率よく照射することが求められる。これを実現するためには、標的周辺の詳細なビームプロファイルをオンラインで測定し、ビームチューニングにフィードバックする必要がある。このためのビームプロファイルモニタには、高空間分解能とリアルタイム性が要求される。我々は、J-PARCミュオン科学実験施設の$$mu$$SR分光器との共存を考慮して、新たにコンパクトなミュオンビームプロファイルモニタを開発した。このプロファイルモニタは、プラスチックシンチレータ、ゲートイメージインテンシファイア(ゲートII)、および冷却CCDカメラを主要コンポーネントとし、ミュオンビームがシンチレータに入射した際に発生したシンチレーション光を撮像することによりビームプロファイルを得る。ゲートIIによって光学像を増強することにより、明瞭なビームプロファイルが約20秒という短時間で得られた。

10 件中 1件目~10件目を表示
  • 1