検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 39 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Laser-driven neutron generation realizing single-shot resonance spectroscopy

余語 覚文*; Lan, Z.*; 有川 安信*; 安部 勇輝*; Mirfayzi, S. R.*; Wei, T.*; 森 隆人*; Golovin, D.*; 早川 岳人*; 岩田 夏弥*; et al.

Physical Review X, 13(1), p.011011_1 - 011011_12, 2023/01

 被引用回数:1 パーセンタイル:90.46(Physics, Multidisciplinary)

Neutrons are powerful tools for investigating the structure and properties of materials used in science and technology. Recently, laser-driven neutron sources (LDNS) have attracted the attention of different communities, from science to industry, in a variety of applications, including radiography, spectroscopy, security, and medicine. However, the laser-driven ion acceleration mechanism for neutron generation and for establishing the scaling law on the neutron yield is essential to improve the feasibility of LDNS. In this paper, we report the mechanism that accelerates ions with spectra suitable for neutron generation. We show that the neutron yield increases with the fourth power of the laser intensity, resulting in the neutron generation of $$3times10^{11}$$ in $$4pi$$ at a maximum, with $$1.1times10^{19}$$ Wcm$$^{-2}$$, 900 J, 1.5 ps lasers. By installing a "hand-size" moderator, which is specially designed for the LDNS, it is demonstrated that the efficient generation of epithermal (0.1-100 eV) neutrons enables the single-shot analysis of composite materials by neutron resonance transmission analysis (NRTA). We achieve the energy resolution of 2.3% for 5.19-eV neutrons 1.8 m downstream of the LDNS. This leads to the analysis of elements and isotopes within sub-$$mu$$s times and allows for high-speed nondestructive inspection.

論文

Low-lying dipole strength in $$^{52}$$Cr

静間 俊行*; 早川 岳人*; 大東 出*; 大垣 英明*; 宮本 修治*; 湊 太志

Physical Review C, 96(4), p.044316_1 - 044316_10, 2017/10

 被引用回数:8 パーセンタイル:55.72(Physics, Nuclear)

準単色線形偏向光子ビームを用いた核共鳴蛍光散乱実験によって、$$^{52}$$Crの低エネルギー双極子強度を測定した。励起状態のパリティは、入射光子ビームの偏極面における共鳴散乱$$gamma$$線の非対称性により決定した。励起エネルギー7.5MeVから12.1MeVまでの磁気双極子(M1)強度の総和は$$sum B(M1)uparrow=5.64(34) mu_N^2$$、電気双極子(E1)強度は$$sum B(E1)uparrow=73.7(23) times 10^{-3} e^2$$ fm$$^2$$という結果が得られた。観測されたM1とE1強度はSkyrme力を用いた乱雑位相近似法計算と比較を行い、双極子強度分布に対する2粒子2空孔状態とテンソル力の影響を調べた。この結果、2粒子2空孔状態とテンソル力の効果がともに、実験データの遷移強度の和を説明するために必要であることが分かった。

論文

Reaction-yield dependence of the ($$gamma$$, $$gamma$$') reaction of $$^{238}$$U on the target thickness

Negm, H.*; 大垣 英明*; 大東 出*; 早川 岳人; Zen, H.*; 紀井 俊輝*; 増田 開*; 堀 利匡*; 羽島 良一; 静間 俊行; et al.

Journal of Nuclear Science and Technology, 52(6), p.811 - 820, 2015/06

 被引用回数:4 パーセンタイル:33.51(Nuclear Science & Technology)

レーザーコンプトン散乱と原子核共鳴蛍光散乱に基づく、核種の非破壊検知、測定において、試料の厚みと測定精度の関係を調べるため、$$^{238}$$Uを試料とした実験を行った。

論文

Status of laser Compton scattered $$gamma$$-ray source at JAEA 150-MeV microtron

羽島 良一; Ferdows, M.; 早川 岳人; 静間 俊行; 神門 正城; 大東 出*; Negm, H.*; 大垣 英明*

Proceedings of 5th International Particle Accelerator Conference (IPAC '14) (Internet), p.1943 - 1945, 2014/07

We have developed a laser Compton scattered $$gamma$$-ray source based on a 150-MeV racetrack microtron at Japan Atomic Energy Agency. The microtron equipped with a photocathode RF gun accelerates a single bunch of electrons to collide with a laser pulse from a Nd:YAG laser. Such $$gamma$$-ray source realizes industrial application of nuclear material detection in a ship cargo, which is one of the urgent requests of international nuclear security. Recent status of $$gamma$$-ray generation experiments and design study of a practical machine is presented.

論文

Analysis of nuclear resonance fluorescence excitation measured with LaBr$$_{3}$$(Ce) detectors near 2 MeV

Omer, M.*; Negm, H.*; 大垣 英明*; 大東 出*; 早川 岳人; Bakr, M.*; Zen, H.*; 堀 利匡*; 紀井 俊輝*; 増田 開*; et al.

Nuclear Instruments and Methods in Physics Research A, 729, p.102 - 107, 2013/11

 被引用回数:6 パーセンタイル:44.21(Instruments & Instrumentation)

LaBr$$_{3}$$(Ce)シンチレータ検出器による原子核共鳴蛍光散乱(NRF)の測定性能を、ゲルマニウム検出器と比較して議論した。多くの核物質が励起準位をもつ2MeV領域に着目した。Duke大学の高強度$$gamma$$線施設(HIGS)において、2.12MeV$$gamma$$線をB$$_{4}$$C試料に照射し、$$^{11}$$Bの共鳴を測定した。測定データに対してSNIPアルゴリズムによるバックグラウンドの処理を行い、LaBr$$_{3}$$(Ce)検出器の測定限界を求めた。

論文

Nuclear resonance fluorescence of $$^{235}$$U measured with high-resolution LaBr$$_3$$(Ce) scintillation detectors

Omer, M.*; Negm, H.*; Zen, H.*; 大東 出*; 紀井 俊輝*; 増田 開*; 大垣 英明*; 羽島 良一; 静間 俊行; 早川 岳人; et al.

Japanese Journal of Applied Physics, 52(10), p.106401_1 - 106401_4, 2013/10

 被引用回数:7 パーセンタイル:30.83(Physics, Applied)

Duke大学の高強度$$gamma$$線施設(HIGS)からのエネルギー1733keVの準単色$$gamma$$線ビームを用いて、$$^{235}$$Uの原子核共鳴蛍光散乱(NRF)の測定を行った。検出器として、LaBr$$_{3}$$(Ce)シンチレータ(長さ7.62cm、直径3.81cm)を8本組み合わせたアレイを用いた。また、4本のゲルマニウム検出器(相対効率60%)を比較のために用いた。LaBr$$_3$$(Ce)で測定したNRFの積分断面積が、過去のデータとよく一致することを確認した。

論文

Generation of laser Compton scattered $$gamma$$-rays from a 150-MeV microtron

羽島 良一; 早川 岳人; 静間 俊行; Angell, C.; 大東 出; 神門 正城; 大垣 英明*

Proceedings of 4th International Particle Accelerator Conference (IPAC '13) (Internet), p.3645 - 3647, 2013/05

We have developed a laser Compton scattered $$gamma$$-ray source based on a 150-MeV racetrack microtron at Japan Atomic Energy Agency. The microtron equipped with a photocathode RF gun accelerates a single bunch of electrons to collide with a laser pulse from a Nd:YAG laser. We have employed laser pulse compression by stimulated Brillouin scattering to obtain high-flux $$gamma$$-rays, $$>$$ 10$$^{5}$$ ph/s. The $$gamma$$-ray source is a prototype of commercial machine for nuclear security applications, non-destructive detection of nuclear material hidden in a ship cargo. Design and performance of the $$gamma$$-ray source are presented.

論文

SBSパルス圧縮による高輝度レーザーコンプトン$$gamma$$線源

大東 出; 神門 正城; 静間 俊行; 早川 岳人; Angell, C.; 羽島 良一; 大垣 英明*

プラズマ・核融合学会誌, 88(10), p.553 - 554, 2012/10

科学技術戦略推進費「安全・安心な社会のための犯罪・テロ対策技術等を実用化するプログラム"$$gamma$$線による核物質非破壊検知システム"」においてレーザーコンプトン散乱$$gamma$$線を用いた核物質非破壊検知システムにおいて必要とされる高輝度$$gamma$$線源開発を行っている。市販のNd:YAGレーザーのパルス幅を誘導ブリルアン散乱によるパルス圧縮を行い、パルス幅を300ps程度に圧縮し、電子ビームとの衝突点でのレーザー光子密度を上げることにより$$gamma$$線発生量を非圧縮の場合に比べ2桁増加させた。

論文

High flux laser-Compton scattered $$gamma$$-ray source by compressed Nd:YAG laser pulse

大東 出; 神門 正城; 小瀧 秀行; 林 由紀雄; 静間 俊行; 早川 岳人; 羽島 良一; 大垣 英明*

Proceedings of 3rd International Particle Accelerator Conference (IPAC '12) (Internet), p.4124 - 4126, 2012/05

原子力機構と京都大学では核テロ防止を目的とした、貨物コンテナ中に隠された核物質の非破壊検知システムの開発を行っている。このシステムでは核物質の共鳴準位に合わせたエネルギーを持つレーザーコンプトン散乱(LCS)による単色$$gamma$$線を用い、コンテナ中に隠された核物質からのNuclear Resonant Fluorescenceからの$$gamma$$線を計測することにより、核物質の同位体の同定を行うことを可能とする。核物質検知に必要とされる$$gamma$$線量は毎秒3$$times$$10$$^{5}$$個程度と見積もられ、これは既に行われた原子力機構のマイクロトロンにおけるLCS-$$gamma$$線収量の100倍に相当する。必要とされる線量を達成するため、LCSに用いるNd:YAGレーザーのパルス幅(10ns)を誘導ブリユアン散乱(SBS)により200ps程度まで圧縮し、レーザー強度を上げることにより、$$gamma$$線収量の増強を図る。パルス圧縮されたNd:YAGレーザーと原子力機構マイクロトロン加速器からの150MeV電子ビームとを用い、400keVのLSC-$$gamma$$線の発生実験を行った。レーザーパルス圧縮と$$gamma$$線発生の実験結果について報告する。

論文

Measurement of deuteron induced thick target neutron yields at 9 MeV

執行 信寛*; 日高 浩介*; 平林 慶一*; 中村 泰博*; 森口 大輔*; 隈部 正洋*; 平野 秀峻*; 平山 嵩祐*; 内藤 有紀*; 本岡 親英*; et al.

Journal of the Korean Physical Society, 59(2), p.1725 - 1728, 2011/08

The double differential thick target neutron yields from 9 MeV deuteron incidences were measured at the Kyushu University Tandem Accelerator Laboratory. A copper and a titanium foils which are thick enough for a deuteron to stop in the foils were placed at the center of a vacuum chamber. An NE213 liquid organic scintillator was employed to detect neutrons emitted from targets and placed at 9 directions from 0$$^{circ}$$ to 140$$^{circ}$$. To consider the contribution of scattered neutrons from the floor, we also measured neutron yields with an iron shadow bar located in front of the scintillator. Because incident deuteron beam was not pulsed and the Time-of-Flight method was not applied, the energy spectrum was derived from unfolding the light output spectrum using the FORIST code. The detection efficiency was calculated with the SCINFUL-QMD code. The experimental results were compared with the calculation data of the TALYS code, and it turned out that the calculation data does not reproduce the experimental ones satisfactorily.

論文

Development of a sub-MeV X-ray source via Compton backscattering

川瀬 啓悟; 神門 正城; 早川 岳人; 大東 出; 近藤 修司; 本間 隆之; 亀島 敬*; 小瀧 秀行; Chen, L. M.*; 福田 祐仁; et al.

Nuclear Instruments and Methods in Physics Research A, 637(1, Suppl.), p.S141 - S144, 2011/05

 被引用回数:7 パーセンタイル:49.05(Instruments & Instrumentation)

関西光科学研究所において実施しているマイクロトロン加速器で加速された150MeVの電子ビームとNd:YAGレーザーとを用いた逆コンプトン散乱によるsub-MeV領域のX線発生についての研究の現状を報告する。特にこれまでに実施したX線発生実験と発生X線の高強度化のためのNd:YAGレーザーのパルス圧縮について報告する。

論文

Spins and parities of astrophysically important $$^{30}$$S states from $$^{28}$$Si($$^{3}$$He, $$n$$$$gamma$$)$$^{30}$$S

Setoodehnia, K.*; Chen, A. A.*; 小松原 哲郎*; 久保野 茂*; Binh, D. N.*; Carpino, J. F.*; Chen, J.*; 橋本 尚志*; 早川 岳人; 石橋 陽子*; et al.

Physical Review C, 83(1), p.018803_1 - 018803_4, 2011/01

 被引用回数:12 パーセンタイル:60.85(Physics, Nuclear)

$$^{30}$$Sの陽子が非束縛な状態は、古典的な新星爆発やI型X線バーストにおける水素爆発の温度での$$^{29}$$P($$p$$, $$gamma$$)$$^{30}$$S熱核反応率を強く影響する。特に、スピンとパリティが3$$^{+}$$と2$$^{+}$$の同定されている4.7から4.8MeVの励起エネルギーに存在する未観測の2つの状態が反応率に強く影響すると予言されている。最近の実験では、2つの候補の状態が4.699MeVと4.814MeVに観測されたが、実験的にはスピンとパリティの情報が得られていない。われわれは$$^{28}$$Si($$^{3}$$He, $$n$$$$gamma$$)$$^{30}$$S反応を用いて、$$^{30}$$Sのインビーム$$gamma$$線核分光を行った。スピンとパリティはよく知られているミラー核の状態との比較から同定した。

論文

Improvement of SBS laser pulse compression system for the Compton backscattered X-ray source

川瀬 啓悟; 神門 正城; 早川 岳人; 大東 出; 近藤 修司; 本間 隆之; 亀島 敬*; 小瀧 秀行; Chen, L. M.*; 福田 祐仁; et al.

JAEA-Conf 2010-002, p.95 - 98, 2010/06

前回の光量子シンポジウムにおいて発表したように、逆コンプトン散乱X線のフラックスを増大させるために、誘導ブリルアン散乱(SBS)によるレーザーパルスの圧縮を提案し、実際に試験を行った。その後、イメージリレーを導入することでSBSパルス圧縮システムの改善を実施した。結果、パルスエネルギー0.84Jで2.1nsの安定した圧縮パルスの発生を達成した。関西光科学研究所における逆コンプトン散乱X線源にこのシステムを導入することで、これまでの3.2倍の強度のX線フラックスの発生が期待できる。

論文

内視鏡画像における組織形状計測システムの開発と基礎検証

岡 潔; 関 健史*; 内藤 岳人*; 渡邉 真也*; 若林 貴夫*; 長縄 明大*; 乾 和郎*; 芳野 純治*

日本画像医学雑誌, 28(1), p.12 - 24, 2010/05

これまでに開発してきた「胎児外科治療用レーザー鉗子型内視鏡」に搭載した距離計測機能に着目し、従来使用されている上部消化器内視鏡との組合せにより、胃内の病変部の形状計測を行うことを提案した。すなわち、対象の形状を簡易的に計測可能な機能を内視鏡に付加する代わりに、システム全体は可能な限りシンプルな構成とし、従来の内視鏡をそのまま使用可能にすることでシステム全体の低コスト化を図った。さらには、別途開発を進めた外径$$phi$$1.1mmの複合型光ファイバスコープを従来の内視鏡に組み込むことで、本ファイバの特徴である、(1)ファイバスコープ映像の取得,(2)治療用レーザーの照射,(3)半導体レーザーによる距離計測及び血流計測を同時に行える機能をそのまま従来の内視鏡に付加できることを提案した。また、健常者の胃壁に対して本システムを適用する臨床試験を実施し、実際に適用可能であることを示した。

論文

イレウスチューブを用いた小腸内圧計測システムの開発

石川 寛子; 岡 潔; 長縄 明大*; 芳野 純治*; 若林 貴夫*; 渡邊 真也*; 内藤 岳人*

日本機械学会論文集,C, 75(756), p.2359 - 2361, 2009/08

消化管では、機能的疾患の診断,重症度の判定,治療方針の決定,治癒の判定を目的とし内圧計測が行われている。小腸も種々の方法による内圧計測が行われてきたが、これらの方法は患者への苦痛や負担を伴う場合があることや、電気的要素を体内に取り込む場合もあることから、あまり好ましくない。そこで本研究では、腸閉塞の治療に使われるイレウスチューブを用いて、患者への負担がなく、無侵襲に小腸の内圧を計測するシステムを開発した。また、その装置の基礎性能試験を行ったところ、約2.8秒の整定時間でバルーンにかかる圧力を計測できることを確認した。

論文

MeV- and sub-MeV-photon sources based on Compton backscattering at SPring-8 and KPSI-JAEA

川瀬 啓悟; 神門 正城; 早川 岳人; 大東 出; 近藤 修司; 本間 隆之; 亀島 敬; 小瀧 秀行; Chen, L.*; 福田 祐仁; et al.

Nuclear Physics Review, 26(Suppl.), p.94 - 99, 2009/07

SPring-8とKPSI-JAEAにおいて、それぞれMeV領域,sub-MeV領域の逆コンプトン散乱による光源を開発した。MeV光源は光励起型遠赤外レーザーと8GeV電子ビームとからなっている。sub-MeV光源はNd:YAGパルスレーザーとマイクロトロンで加速された150MeV電子ビームからなっている。どちらの光源も逆コンプトン光の発生に成功した。ここでは、これらの光源の特徴と今後の展望について発表する。

論文

"J-KAREN"高強度レーザー

桐山 博光; 森 道昭; 中井 善基; 下村 拓也*; 田上 学*; 圷 敦; 岡田 大; 本村 朋洋*; 近藤 修司; 金沢 修平; et al.

JAEA-Conf 2008-007, p.13 - 16, 2008/08

高強度場科学研究において、メインパルスと背景光(ASE光)との強度比であるコントラストが、高強度レーザーを利用するうえでボトルネックになっている。高強度レーザーシステムより出力されるレーザーパルスの時間構造において、メインパルスに先立って数桁強度の低い背景光(ASE)が存在する。一般的な高強度レーザーシステムにおいて、メインパルスとASEの強度比(コントラスト)は10$$^{-5}$$$$sim$$10$$^{-6}$$桁程度であり、この場合ASEの光強度は10$$^{12}$$$$sim$$10$$^{13}$$W/cm$$^{2}$$となり、高強度を有するメインパルスが固体物質と相互作用する前にターゲット上にプリプラズマが形成され、メインパルスは膨張しつつある低い密度のプラズマと主として相互作用し、メインパルスと物質との相互作用に影響を及ぼす。このため多くの実験において、プリパルスによりプリプラズマが形成されないようなレーザーの時間制御技術開発が必要である。われわれは背景光が発生しにくい光パラメトリックチャープパルス増幅(OPCPA)を前置増幅器として用いた高強度レーザーシステムの開発を行った。OPCPAを用いることにより、メインパルスの数ps前において従来よりも1,000$$sim$$10,000倍改善された7$$times$$10$$^{-9}$$の高いコントラストを実現した。

論文

Sub-MeV tunably polarized X-ray production with laser Thomson backscattering

川瀬 啓悟; 神門 正城; 早川 岳人; 大東 出; 近藤 修司; 本間 隆之; 亀島 敬; 小瀧 秀行; Chen, L.-M.; 福田 祐仁; et al.

Review of Scientific Instruments, 79(5), p.053302_1 - 053302_8, 2008/05

 被引用回数:19 パーセンタイル:62.52(Instruments & Instrumentation)

本論文では、波長1064nmのNd:YAGレーザー光とマイクロトロン加速器からの150MeV電子ビームとの逆トムソン散乱によるsub-MeV領域の偏光X線の発生について報告している。発生するX線の最大エネルギーはおよそ400keVである。実験では、X線パルスの全エネルギーをLYSOシンチレーターで測定した。また、X線の角度発散をイメージングプレートを用いて測定した。X線ビームがレーザーの偏光方向に沿って偏光していることはコンプトン散乱法を用いて確認した。これらに加えて、ここで発生させたX線を用いて鉛で遮蔽された物体のイメージングも実施した。

論文

Transfer function analysis of positron-emitting tracer imaging system (PETIS) data

Keutgen, N.; 松橋 信平; 水庭 千鶴子; 伊藤 岳人*; 藤村 卓; 石岡 典子; 渡辺 智; 関根 俊明; 内田 博*; 橋本 昭司

Applied Radiation and Isotopes, 57(2), p.225 - 233, 2002/09

 被引用回数:10 パーセンタイル:54.94(Chemistry, Inorganic & Nuclear)

植物内での物質移行の定量解析の試みとして、植物用ポジトロンイメージング装置(PETIS)での計測結果の伝達関数法による解析を行った。植物としてニラあるいはダイズを用い、葉あるいは茎の切り口から$$^{13}$$N-硝酸及び$$^{18}$$F-水溶液を投与し、得られた分布変化の画像を伝達関数法により解析し、ポジトロン放出核種の見かけの移行速度を求めた。その結果、ニラ葉中の$$^{18}$$F-水溶液の移行速度は1.2cm/min、ダイズ3小葉の中葉での$$^{18}$$F-水溶液の移行速度は10.7cm/min、$$^{13}$$N-硝酸は11.9cm/minとなり、ダイズの小葉では硝酸と水の移行速度とほぼ同じであることが明らかとなった。これらの結果は、伝達関数法によるPETIS計測データの解析が、植物中での物質移行の定量化に有効な手法であることを示しており、環境ストレス要因が植物に与える影響の評価に役立つと考えられる。

論文

Vanadium uptake and an effect of vanadium treatment on $$^{18}$$F-labeled water movement in a cowpea plant by positron emitting tracer imaging system (PETIS)

古川 純*; 横田 はる美*; 田野井 慶太朗*; 上岡 志ほり*; 松橋 信平; 石岡 典子; 渡辺 智; 内田 博*; 辻 淳憲*; 伊藤 岳人*; et al.

Journal of Radioanalytical and Nuclear Chemistry, 249(2), p.495 - 498, 2001/08

 被引用回数:14 パーセンタイル:71.26(Chemistry, Analytical)

ポジトロン放出核種を利用したイメージング装置であるPETIS(Positron Emitting Tracer Imaging System)を用いてササゲにおけるバナジウム(V$$^{5+}$$)吸収をリアルタイムで測定した。バナジウム-48は、日本原子力研究所高崎研究所のAVFサイクロトロンを用い、Sc箔に50MeVの$$alpha$$粒子を照射することにより製造した。$$^{48}$$Vを水耕液に添加し、PETISによりリアルタイム計測を行った。また$$^{48}$$V水溶液を添加してから3,6,20時間目の植物体を用いてバナジウム分布をラジオグラフィにより測定した。これらにより処理開始後20時間目には植物体全体にバナジウムが分布していることが明らかになった。植物に吸収されたバナジウムが及ぼす影響を見るために、同様にポジトロン放出核種であるフッ素-18で標識した水を用いてPETISによりササゲの水分吸収動態を測定した。計測前に20時時間バナジウムを吸収させると、標識水の吸収が極端に抑えられることが示された。これらの結果は植物体の地上部に移行したバナジウムが標識水の吸収を阻害する主な原因であることを示唆している。

39 件中 1件目~20件目を表示