Chimi, Yasuhiro; Iwase, Akihiro*; Ishikawa, Norito; Kobiyama, Mamoru*; Inami, Takashi*; Kambara, Tadashi*; Okuda, Shigeo*
Nuclear Instruments and Methods in Physics Research B, 245(1), p.171 - 175, 2006/04
Times Cited Count:16 Percentile:72.60(Instruments & Instrumentation)We have studied effects of irradiation with energetic particles on defect accumulation in nanocrystalline gold (nano-Au). The specimens of nano-Au foil (3-5 m thickness) with various grain sizes (23-156 nm) are prepared by the gas deposition method and subsequent thermal annealings. Irradiations of the specimens with 60-MeV C ions, 3.54-GeV Xe ions or 2.0-MeV electrons are performed at low temperature. The defect accumulation behavior is observed by measuring the electrical resistivity change during irradiation. Through an analysis of defect accumulation behavior, cross-sections for defect production, , and annihilation, , in nano-Au increase monotonically as the grain size decreases. These results are considered to be caused by the existence of a large volume fraction of the regions near grain boundaries in nano-Au where the threshold energy for atomic displacements, E, becomes lower than in polycrystalline gold. The possibility of electronic excitation effects in nano-Au is also discussed.
Hiura, Nobuo*; Yamaura, Takayuki; Motohashi, Yoshinobu*; Kobiyama, Mamoru*
Nihon Genshiryoku Gakkai Wabun Rombunshi, 1(2), p.202 - 208, 2002/06
The purpose of this study is to develop oxygen sensor which can measure the oxygen potential of the fuel in a nuclear reactor. The oxygen sensor with CaO stabilized zirconia solid electrolyte has been specially designed in order to prolong its life time. Electromotive force (EMF) of solid galvanic cell Ni/NiO|ZrO-CaO|Fe/FeO was measured in both the out-pile tests and the in-situ tests using Japan Material Testing Reactor (JMTR), and the characteristics of EMF was discussed. In the out-pile test, it was found that the EMF was almost equal to the theoretical values at temperatures ranging from 700 to 1,000, and the life span of the sensor was very long up to 980h at 800. In the in-situ test, it was found that the EMF showed almost the reliable values up to 300 h (neutron fluence (E 1 MeV) 1.510 m), at temperatures from 700 to 900. The imprecision of the EMF was found to be within 6% of the theoretical values up to 1,650 h irradiation time (neutron fluence (E 1 MeV) 8.010 m) at 800. The oxygen sensors were found to be applicable for the oxygen potential measurement of the fuels in a reactor.
Matsunami, Noriaki*; Sataka, Masao; Iwase, Akihiro; Inami, Takashi*; Kobiyama, Mamoru*
Journal of Nuclear Materials, 302(2-3), p.206 - 210, 2002/04
Times Cited Count:8 Percentile:47.73(Materials Science, Multidisciplinary)no abstracts in English
Chimi, Yasuhiro; Iwase, Akihiro; Ishikawa, Norito; Kobiyama, Mamoru*; Inami, Takashi*; Okuda, S.*
Journal of Nuclear Materials, 297(3), p.355 - 357, 2001/09
Times Cited Count:217 Percentile:98.84(Materials Science, Multidisciplinary)no abstracts in English