Nishimura, Satoshi*; Satake, Masaaki*; Soga, Shota*; Nishi, Yoshihisa*; Kaji, Yoshiyuki; Nemoto, Yoshiyuki
no journal, ,
Using the severe accident code MAAP5.03, simulation of the loss of cooling function accident in spent fuel pool was conducted and cooling performance of the emergency cooling systems such as spray or water inlet was evaluated.
Nishimura, Satoshi*; Satake, Masaaki*; Soga, Shota*; Nishi, Yoshihisa*; Kaji, Yoshiyuki; Nemoto, Yoshiyuki
no journal, ,
We conducted the transient analysis for the phenomenon of loss of coolant in Spent Fuel Pool by Severe Accident code MAAP version 5.03 and evaluated quantitatively the influence of initial water level and decay heat on failure time and hydrogen generation of fuel cladding.