Neutron resonance fission neutron analysis for nondestructive fissile material assay

弘中 浩太; Lee, J.; 小泉 光生; 伊藤 史哲*; 堀 順一*; 寺田 和司*; 佐野 忠史*

Nuclear Instruments and Methods in Physics Research A, 1054, p.168467_1 - 168467_5, 2023/09

We propose neutron resonance fission neutron analysis (NRFNA), an active nondestructive assay (NDA) technique, to improve the capability to identify and quantify a small amount of fissile material in a sample. NRFNA uses pulsed neutrons to induce fission reactions in the sample. Fission neutrons are detected by a neutron-gamma pulse shape discrimination (PSD) scintillation detector with time-of-flight (TOF) technique. The obtained nuclide-specific resonance peaks in the neutron energy spectrum provide information to identify and quantify a fissile material in the sample. The possibility of using PSD for NRFNA was confirmed through a test experiment using a natural uranium sample. We successfully observed the resonance peaks from $$^{235}$$U(n,f) reaction and showed that NRFNA would be useful for measuring a small amount of fissile material in a sample.

論文

Neutron total and capture cross-section measurements of $$^{155}$$Gd and $$^{157}$$Gd in the thermal energy region with the Li-glass detectors and NaI(Tl) spectrometer installed in J-PARC$$cdot$$MLF$$cdot$$ANNRI

木村 敦; 中村 詔司; 遠藤 駿典; Rovira Leveroni, G.; 岩本 修; 岩本 信之; 原田 秀郎; 片渕 竜也*; 寺田 和司*; 堀 順一*; et al.

Journal of Nuclear Science and Technology, 60(6), p.678 - 696, 2023/06

 被引用回数:2 パーセンタイル:56.43(Nuclear Science & Technology)

Neutron total and capture cross-section measurements of $$^{155}$$Gd and $$^{157}$$Gd were performed in the ANNRI at the MLF of the J-PARC. The neutron total cross sections were determined in the energy region from 5 to 100 meV. At the thermal neutron energy, the total cross sections were obtained to be 59.4$$pm$$1.7 and 251.9$$pm$$4.6 kilobarn for $$^{155}$$Gd and $$^{157}$$Gd, respectively. The neutron capture cross sections were determined in the energy region from 3.5 to 100 meV with an innovative method by taking the ratio of the detected capture event rate between thin and thick samples. At the thermal energy, the capture cross sections were obtained as 59.0$$pm$$2.5 and 247.4$$pm$$3.9 kilobarn for $$^{155}$$Gd and $$^{157}$$Gd, respectively. The present total and capture cross sections agree well within the standard deviations. The results for $$^{155}$$Gd were found to be consistent with the values in JENDL-4.0 and the experimental data given by Mastromarco et al. and Leinweber et al. within one standard deviation. Moreover, the present results for $$^{157}$$Gd agreed with the evaluated data in JENDL-4.0 and the experimental data by M${o}$ller et al. within one standard deviation and agreed with the data by Mastromarco et al. within 1.4 standard deviations. However, they disagree (11% larger) with the experimental result by Leinweber et al.

論文

Fast-neutron capture cross section data measurement of minor actinides for development of nuclear transmutation systems

片渕 竜也*; 岩本 修; 堀 順一*; 木村 敦; 岩本 信之; 中村 詔司; Rovira Leveroni, G.; 遠藤 駿典; 芝原 雄司*; 寺田 和司*; et al.

EPJ Web of Conferences, 281, p.00014_1 - 00014_4, 2023/03

Long-lived minor actinides (MA) in nuclear waste from nuclear power plants are a long-standing issue to continue nuclear energy production. To solve the issue, researchers have suggested nuclear transmutation, in which long-lived radionuclides are transmuted into stable or shorter-life nuclides via neutron-induced nuclear reactions. Development of nuclear transmutation systems as an accelerator-driven system requires accurate neutron nuclear reaction data. The present research project entitled "Study on accuracy improvement of fast-neutron capture reaction data of long-lived MAs for development of nuclear transmutation systems" have been conducted as a joint collaboration, including Tokyo Tech, Japan Atomic Energy Agency and Kyoto University. This project focuses on the neutron capture reaction of MAs, especially $$^{237}$$Np, $$^{241}$$Am and $$^{243}$$Am, in the fast neutron energy region. The final goal of this project is to improve the accuracies of the neutron capture cross sections of $$^{237}$$Np, $$^{241}$$Am and $$^{243}$$Am employing a high-intensity neutron beam from a spallation source of the Japan Proton Accelerator Research Complex (J-PARC) that reduces uncertainties of measurement. To achieve the goal, a neutron beam filter system in J-PARC, sample characteristic assay, and theoretical reaction model study were developed. In this contribution, the overview and results of the project will be presented.

論文

Development of a neutron beam monitor with a thin plastic scintillator for nuclear data measurement using spallation neutron source

中野 秀仁*; 片渕 竜也*; Rovira Leveroni, G.; 児玉 有*; 寺田 和司*; 木村 敦; 中村 詔司; 遠藤 駿典

Journal of Nuclear Science and Technology, 59(12), p.1499 - 1506, 2022/12

 被引用回数:0 パーセンタイル:33.72(Nuclear Science & Technology)

A neutron monitoring detection system was developed for neutron capture cross section measurement using a spallation neutron source. A combination of a plastic scintillator and a thin $$^{6}$$LiF foil was adopted for the detector. The detector system was tested to study the feasibility of the system. Neutron irradiation experiments were conducted with the Accurate Neutron-Nucleus Reaction Measurement Instrument in the Materials and Life Science facility of the Japan Proton Accelerator Research Complex. A neutron time-of-flight spectrum was successfully measured without significant count loss or detector paralysis. The statistical uncertainty reached 0.7% at neutron energies around 6 meV.

論文

リチウムガラスシンチレータのガンマ線と中性子に対する応答特性

Lee, J.; 伊藤 史哲*; 弘中 浩太; 高橋 時音; 鈴木 敏*; 小泉 光生; 堀 順一*; 寺田 和司*

第43回日本核物質管理学会年次大会会議論文集(インターネット), 4 Pages, 2022/11

中性子検出に広く使われているGS20リチウムガラスシンチレータは、応答は速いがn/g弁別能に乏しい。ガンマ線背景事象を適切に評価するためには、ガンマ線に対する応答特性を知る必要がある。特に中性子測定時は減速材中の水素原子核から発生する2.2MeVのガンマ線が主な背景事象となるが、このような高エネルギーガンマ線への応答特性の報告はほとんどない。このため、本研究では、GS20の応答特性についてNa-24ガンマ線源を用いて調べた。

論文

Development of a neutron scintillator for a compact NRTA system, 2

Lee, J.; 弘中 浩太; 伊藤 史哲*; 高橋 時音; 小泉 光生; 堀 順一*; 寺田 和司*

KURNS Progress Report 2021, P. 97, 2022/07

文部科学省補助金事業「核セキュリティ強化等推進事業費補助金」の下、核不拡散技術開発の一環として、レーザー駆動中性子源(LDNS)を用いたコンパクトな核共鳴透過分析(NRTA)システムの技術開発を行っている。コンパクトなNRTAシステムを構築するためには、中性子の飛行距離を短くすることが重要な要素である。しかし、短距離のTOF測定では、減速材中の水素への中性子捕獲による2.2MeVガンマ線の影響が短距離に比例して指数的に大きくなってしまう。また、LDNSは発展途上であるため、中性子フラックスが十分ではなく、検出効率の高い検出器を用いることが望ましい。このため、我々は、高エネルギーガンマ線に対する検出効率が低く、かつ高い中性子感度を持つ検出器(積層型中性子検出器)を開発してきた。令和3年度の京都大学LINAC実験では、中性子に対する検出効率を上げ、両側にPMTを取り付け、コインシデンス測定によりノイズを除去できるようになった改良型の積層型中性子検出器の性能評価を行い、共鳴TOF測定による良いパフォーマンスを確かめられた。

論文

KeV-neutron capture cross-section measurement of $$^{197}$$Au with a Cr-filtered neutron beam at the ANNRI beamline of MLF/J-PARC

Rovira Leveroni, G.; 木村 敦; 中村 詔司; 遠藤 駿典; 岩本 修; 岩本 信之; 片渕 竜也*; 児玉 有*; 中野 秀仁*; 佐藤 八起*; et al.

Journal of Nuclear Science and Technology, 59(5), p.647 - 655, 2022/05

 被引用回数:1 パーセンタイル:16.97(Nuclear Science & Technology)

Cr-filtered keV-neutron experiments were performed in the Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) beamline in the Materials and Life Science (MLF) facility of the Japan Proton Accelerator Research Complex (J-PARC) to measure the neutron capture cross-section of $$^{197}$$Au. The energy range of the neutron filtering system at ANNRI was extended through the use of 15 cm of $$^{nat}$$Cr as filter material to tailor quasi-monochromatic neutron peaks with averaged neutron energies of 133.4 and 45.0 keV. The performance of the $$^{nat}$$Cr filter assembly was evaluated by means of experimental capture and transmission analyses, together with the use of Monte-Carlo simulations. The present $$^{197}$$Au neutron capture cross-section results provide agreement within uncertainties with the JENDL-4.0 standard evaluated library and the IAEA standard data library further demonstrating the capabilities of the neutron filtering system at ANNRI.

論文

Neutron filtering system for fast neutron cross-section measurement at ANNRI

Rovira Leveroni, G.; 岩本 修; 木村 敦; 中村 詔司; 岩本 信之; 遠藤 駿典; 片渕 竜也*; 寺田 和司*; 児玉 有*; 中野 秀仁*; et al.

JAEA-Conf 2021-001, p.156 - 161, 2022/03

A neutron filtering system has been designed in order to bypass the double-timed structure of the beam. Filter materials were introduced into the rotary collimator of the ANNRI beamline in order to produce quasi-monoenergetic neutron filtered beams. Filter assemblies consisting of Fe with a thickness of 20 cm, and Si with thicknesses of 20 cm and 30 cm of Si were used separately to produce filtered neutron peaks with energies of 24 keV (Fe) and of 54 and 144 (Si). In this study, the characteristics and performance of the neutron filtering system at ANNRI using Fe and Si determined from both measurements and simulations are presented. The incident neutron flux was tested and analyzed by means of transmission and capture experiments. Moreover, simulations using the PHITS code were performed in order to determine the energy distribution of the integrated filtered peaks and assess the reliability of experimental results. Finally, preliminary results of the capture cross section of $$^{197}$$Au at the filtered energies of 24, 54 and 144 keV are also presented using the NaI(Tl) spectrometer alongside the neutron filtering system.

論文

Development of a neutron beam monitor for nuclear data measurement using spallation neutron source

中野 秀仁*; 片渕 竜也*; Rovira Leveroni, G.*; 児玉 有*; 寺田 和司*; 木村 敦; 中村 詔司; 遠藤 駿典

JAEA-Conf 2021-001, p.166 - 170, 2022/03

In neutron capture cross section measurement, monitoring the number of the incident neutrons is necessary. However, in measurement with J-PARC/ANNRI, direct neutron monitoring system has not been employed. Conventional neutron detectors cannot be used as a beam monitor at ANNRI because of two reasons, high counting rate environment and gamma-flash. In general, a semiconductor detector or an inorganic scintillator, which is adopted for a neutron detector, has relatively longer response time and is unsuitable for beam monitoring at ANNRI. Therefore, a combination of a thin plastic scintillator and a $$^{6}$$LiF foil was selected as a detection system, whose fast response enabled detecting neutrons at a high counting rate. Low gamma ray sensitivity of a thin plastic scintillator allows measuring fast TOF region without count loss or detector paralysis. The geometry of the $$^{6}$$LiF foil, the plastic scintillator, and photomultiplier tube (PMT) was designed. The optimal thickness of the $$^{6}$$LiF foil was determined with simulation codes, SRIM and PHITS. The detector system was tested under the high neutron irradiation condition at J-PARC /ANNRI. A neutron TOF spectrum was successfully measured without significant count loss or detector paralysis. A neutron energy spectrum was driven from difference of TOF spectrum with and without $$^{6}$$LiF. The neutron spectrum was compared with a past neutron spectrum and good agreement was obtained. Statistic error was 0.68 $$%$$ at 6.0 meV even though measurement times in this study were short.

論文

A New method to reduce systematic uncertainties of capture cross section measurement using a sample rotation system

児玉 有*; 片渕 竜也*; Rovira Leveroni, G.; 中野 秀仁*; 寺田 和司*; 木村 敦; 中村 詔司; 遠藤 駿典

JAEA-Conf 2021-001, p.162 - 165, 2022/03

Precise nuclear data for neutron-induced reactions are necessary for the design of nuclear transmutation systems. Nevertheless, current uncertainties of nuclear data for minor actinide (MA) does not achieve requirements for the design of transmutation facilities. The determination of an incident neutron flux for measurements of neutron capture cross section is one of the main causes that affect the final uncertainty of the cross section results. In the present work, we suggest a new method to reduce systematic uncertainties of capture cross section measurements. The method employs change of the self-shielding effect with sample rotation angle. In capture cross section measurements in ANNRI, a boron sample is placed to determine the incident neutron spectrum by counting 478 keV $$gamma$$-ray from the $$^{10}B(n,alphagamma)^{7}Li$$ reaction. In this method, the boron sample is tilted with respect to the neutron beam direction, thereby changing the effective area. This results in change of the shapes of time-of-flight (TOF) spectrum of 478 keV $$gamma$$-ray from the $$^{10}B(n,alphagamma)^{7}Li$$ reaction with the tilted angle. Comparing the difference of the TOF spectra at different angles and assuming the 1/v energy dependence of cross section of the $$^{10}B(n,alphagamma)^{7}Li$$ reaction, the area density of the boron sample can be determined without using the sample mass and area. Theoretical and experimental studies on the new method are ongoing. Calculation using Monte Carlo simulation code PHITS were carried out to study the feasibility of the present method. Test experiments using a sample rotation system at ANNRI were also performed.

論文

Neutron capture and total cross-section measurements and resonance parameter analysis of niobium-93 below 400 eV

遠藤 駿典; 木村 敦; 中村 詔司; 岩本 修; 岩本 信之; Rovira Leveroni, G.; 寺田 和司*; 明午 伸一郎; 藤 暢輔; 瀬川 麻里子; et al.

Journal of Nuclear Science and Technology, 59(3), p.318 - 333, 2022/03

 被引用回数:2 パーセンタイル:66.98(Nuclear Science & Technology)

In order to improve the accuracy of the cross-section and the resonance parameters of $$^{93}$$Nb, neutron capture and total cross-sections were measured using the J-PARC MLF ANNRI. The thermal-neutron capture cross-section was deduced as 0.97$$pm$$0.12 b. The resonance parameters of 11 resonances below 400 eV were determined from obtained capture cross-sections and transmission ratios by using the resonance analysis code, REFIT.

論文

Measurements of the neutron capture cross section of $$^{243}$$Am around 23.5 keV

児玉 有*; 片渕 竜也*; Rovira Leveroni, G.; 木村 敦; 中村 詔司; 遠藤 駿典; 岩本 信之; 岩本 修; 堀 順一*; 芝原 雄司*; et al.

Journal of Nuclear Science and Technology, 58(11), p.1159 - 1164, 2021/11

 被引用回数:3 パーセンタイル:58.27(Nuclear Science & Technology)

The neutron capture cross section of $$^{243}$$Am was measured with a pulsed neutron beam from a spallation neutron source of the Japan Proton Accelerator Research Complex. A Fe neutron beam filter was used to make the incident neutron beam mono-energetic around 23.5 keV. The neutron capture $$gamma$$-rays were detected with a NaI(Tl) detector. The pulse height weighting technique was employed to derive the neutron capture cross section from the pulse height spectrum. The cross section was determined relative to the capture cross section of $$^{197}$$Au of JENDL-4.0. The neutron capture cross section of $$^{243}$$Am was determined with a smaller uncertainty than previous measurements. The previous measurements and the JENDL-4.0 cross sections were found to be lower than the present result.

論文

Development of a neutron sintillator for a compact NRTA system

伊藤 史哲*; Lee, J.; 弘中 浩太; 高橋 時音; 鈴木 敏*; 堀 順一*; 寺田 和司*; 小泉 光生

KURNS Progress Report 2020, P. 98, 2021/08

文部科学省補助金事業「核セキュリティ強化等推進事業費補助金」の下、核不拡散技術開発の一環として、レーザー駆動中性子源(LDNS)を用いたコンパクトな核共鳴透過分析(NRTA)システムの技術開発を行っている。NRTAにおいては、パルス中性子源から放出される中性子エネルギーが、飛行時間(TOF)法を用いて測定される。LDNSは、短い飛行距離でも高精度なTOF測定を行うために必要となる、短いパルス幅を持つという特性等から注目されている。短距離TOF測定では、減速材中の水素への中性子捕獲による2.2MeVガンマ線の飛来タイミングと、共鳴エネルギー付近の中性子の飛来タイミングが重なり、大きなガンマ線背景事象が存在することとなる。また、LDNSは発展途上であるため、中性子フラックスが十分ではなく、検出効率の高い検出器を用いることが望ましい。このため、我々は、高エネルギーガンマ線に対する検出効率が低く、かつ高い中性子感度を持つ検出器(多層型中性子検出器)を開発してきた。令和3年度の実験結果の一つとして、多層型中性子検出器が、高エネルギーガンマ線に対して低感度であることが確かめられた。

論文

Neutron beam filter system for fast neutron cross-section measurement at the ANNRI beamline of MLF/J-PARC

Rovira Leveroni, G.; 木村 敦; 中村 詔司; 遠藤 駿典; 岩本 修; 岩本 信之; 片渕 竜也*; 寺田 和司*; 児玉 有*; 中野 秀仁*; et al.

Nuclear Instruments and Methods in Physics Research A, 1003, p.165318_1 - 165318_10, 2021/07

 被引用回数:3 パーセンタイル:58.42(Instruments & Instrumentation)

A neutron filtering system has been introduced in the Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) beamline in the Material and Life Science (MLF) building of the Japan Proton Accelerator Research Complex (J-PARC) in order to produce quasi-monoenergetic neutron beams. The filtered neutron spectrum by the filter assemblies was analyzed by means of capture and transmission measurements and also by Monte Carlo simulations using PHITS. The characteristics of the filtered neutron beam are discussed alongside its viability in future applications for neutron cross-section measurements in the fast neutron region.

論文

Discovery of a new low energy neutron resonance of $$^{89}$$Y

片渕 竜也*; 藤 暢輔; 水本 元治*; 齋藤 辰宏*; 寺田 和司*; 木村 敦; 中村 詔司; Huang, M.*; Rovira Leveroni, G.; 井頭 政之*

European Physical Journal A, 57(1), p.4_1 - 4_4, 2021/01

 被引用回数:1 パーセンタイル:35.95(Physics, Nuclear)

A new neutron resonance of $$^{89}$$Y was found in time-of-flight (TOF) neutron capture experiments using a pulsed neutron beam from a spallation neutron source of the Japan Proton Accelerator Research Complex. The observed resonance energy was 19.7 eV that is much lower than the lowest energy (2.60 keV) of the previous reported resonances. In addition to the TOF measurement, nuclide identification of the resonance was made by prompt $$gamma$$-ray analysis. Neutron capture $$gamma$$-rays from $$^{89}$$Y were clearly observed only on the resonance. Resonance analysis was applied to the experimental results and the resonance parameters of the new resonance are given.

論文

Neutron capture cross section measurement of minor actinides in fast neutron energy region for study on nuclear transmutation system

片渕 竜也*; 堀 順一*; 岩本 信之; 岩本 修; 木村 敦; 中村 詔司; 芝原 雄司*; 寺田 和司*; 登坂 健一*; 遠藤 駿典; et al.

JAEA-Conf 2020-001, p.5 - 9, 2020/12

A research project entitled "Study on accuracy improvement of fast-neutron capture reaction data of long-lived MAs for development of nuclear transmutation systems" has been ongoing since 2017. The project aims at improving accuracy of neutron capture cross sections of long-lived minor actinides (MAs; $$^{237}$$Np and $$^{241,243}$$Am) in the fast neutron energy region which are very important for development of nuclear transmutation systems. In order to improve the capture reaction data of MAs, measurements using an intense pulsed neutron beam from a spallation neutron source of J-PARC are planned. The project consists of four parts: (1) development of neutron beam filter system, (2) cross section measurement, (3) sample characteristic assay, and (4) theoretical study. The filter system is designed to solve a double bunch issue in J-PARC. The sample characteristic assay lowers systematic uncertainties originating the samples. In the theoretical study, a nuclear reaction model is applied to analyzing cross sections and $$gamma$$-ray spectra measured in experiments. The outline of the project and the current progress will be presented.

論文

Fast neutron capture reaction data measurement of minor actinides for development of nuclear transmutation systems

片渕 竜也*; 岩本 修; 堀 順一*; 木村 敦; 岩本 信之; 中村 詔司; 芝原 雄司*; 寺田 和司*; Rovira, G.*; 松浦 翔太*

EPJ Web of Conferences, 239, p.01044_1 - 01044_4, 2020/09

 被引用回数:1 パーセンタイル:87.03

In 2017, a research project entitled "Study on accuracy improvement of fast-neutron capture reaction data of long-lived MAs for development of nuclear transmutation systems" started as a joint collaboration, including Tokyo Tech, Japan Atomic Energy Agency and Kyoto University. This project focuses on neutron capture reaction of MAs, especially $$^{237}$$Np, $$^{241}$$Am and $$^{243}$$Am, in the fast neutron energy region. The final goal of this project is to improve the neutron capture cross sections of $$^{237}$$Np, $$^{241}$$Am and $$^{243}$$Am employing a high-intensity neutron beam from a spallation source of the Japan Proton Accelerator Research Complex (J-PARC) that reduces uncertainties of measurement. In this contribution, the overview of the project and the current progress will be presented.

論文

Neutron capture cross-section measurement and resolved resonance analysis of $$^{237}$$Np

Rovira, G.*; 片渕 竜也*; 登坂 健一*; 松浦 翔太*; 寺田 和司*; 岩本 修; 木村 敦; 中村 詔司; 岩本 信之; 瀬川 麻里子; et al.

Journal of Nuclear Science and Technology, 57(1), p.24 - 39, 2020/01

 被引用回数:8 パーセンタイル:79.84(Nuclear Science & Technology)

The neutron capture cross-section of $$^{237}$$Np has been measured in the neutron energy region of 10 meV to 500 eV. A neutron time-of-flight method was employed using the NaI(Tl) spectrometer in the ANNRI beam-line at the Japanese Proton Accelerator Re-search Complex (J-PARC). The experimental capture yield was derived using the pulse-height weighting technique and an energy dependent cross-section was obtained relative to the incident neutron spectrum derived from a $$^{10}$$B(n, $$alpha$$)$$^{7}$$Li reaction yield. The absolute cross-section was determined by normalizing the results to JENDL-4.0 cross-section data at the first resonance of $$^{237}$$Np. The thermal cross-section was measured to be 177.6 $$pm$$ 3.8 b. The resolved resonance region was analyzed with the REFIT code.

論文

Neutron capture reaction data measurement of minor actinides in fast neutron energy region for study on nuclear transmutation system

片渕 竜也*; 岩本 修; 堀 順一*; 岩本 信之; 木村 敦; 中村 詔司; 芝原 雄司*; 寺田 和司*

JAEA-Conf 2019-001, p.193 - 197, 2019/11

A research project entitled "Study on improvement of neutron capture reaction data accuracies of long-lived minor actinides in fast neutron energy region for development of nuclear transmutation systems" started in 2017. The project aims at improving accuracies of neutron capture cross section of long-lived minor actinides ($$^{237}$$Np, $$^{241}$$Am, $$^{243}$$Am) in the fast neutron energy region which are very important for development of nuclear transmutation systems. In order to improve the capture reaction data of MA, measurement using an intense pulsed neutron beam from a spallation neutron source of the Japan Proton Accelerator Research Complex (J-PARC) is planned. The neutron beam filter is designed to solve the so-called double bunch issue of a neutron beam in J-PARC. This allows for measuring neutron capture cross sections using the high-intensity neutron beam of J-PARC. The outline of the project and the current progress will be presented.

論文

Measurements of the $$^{243}$$Am neutron capture and total cross sections with ANNRI at J-PARC

木村 敦; 中村 詔司; 寺田 和司*; 中尾 太郎*; 水山 一仁*; 岩本 信之; 岩本 修; 原田 秀郎; 片渕 竜也*; 井頭 政之*; et al.

Journal of Nuclear Science and Technology, 56(6), p.479 - 492, 2019/06

 被引用回数:11 パーセンタイル:85.03(Nuclear Science & Technology)

Neutron total and capture cross sections of $$^{243}$$Am have been measured in Accurate Neutron Nucleus Reaction measurement Instrument at Materials and Life Science Experimental Facility of Japan Proton Accelerator Research Complex with a neutron TOF method. The neutron capture cross section in the energy region from 10 meV to 100 eV was determined using an array of Ge detectors. Three samples with different activities were used for measurements of the capture cross section. The neutron total cross section in the energy region from 4 meV to 100 eV was measured using Li-glass detectors. Derived cross-section value at neutron energy of 0.0253 eV is 87.7$$pm$$5.4 b for the capture cross section and 101$$pm$$11 b for the total cross section.