Refine your search:     
Report No.
 - 
Search Results: Records 1-2 displayed on this page of 2
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Structure of liquid rubidium and liquid sodium under pressure

Morimoto, Yoshiki*; Kato, Sayuri*; Toda, Naohiro*; Katayama, Yoshinori; Tsuji, Kazuhiko*; Yaoita, Kenichi*; Shimomura, Osamu

Review of High Pressure Science and Technology, 7, p.245 - 247, 1998/03

X-ray diffraction for liquid Rb and liquid Na has been measured under pressure up to 6 GPa using synchrotron radiation. Volume dependences of static structure factor $$S(Q)$$ and pair distribution function $$g(r)$$ were obtained to the volume range $$nu(=V/V_{0})$$ of 0.52 for liquid Rb and $$nu$$ of 0.73 for liquid Na to investigate the effect of the electronic change on the structure of liquid metals. With increasing pressure, the peaks of $$S(Q)$$ of both liquid Rb and liquid Na shift towards higher $$Q$$, and the heights of the first peak increase. Theses volume dependences of the structural data are compared with those for other metals under pressure and expanded fluids.

Journal Articles

Angle-dispersive diffraction measurement system for high-pressure experiments using a multichannel collimator

Yaoita, Kenichi*; Katayama, Yoshinori; Tsuji, Kazuhiko*; Kikegawa, Takumi*; Shimomura, Osamu

Review of Scientific Instruments, 68(5), p.2106 - 2110, 1997/05

 Times Cited Count:34 Percentile:87.25(Instruments & Instrumentation)

An optical device called a multichannel collimator (MCC) was developed to rapidly perform an angle-dispersive diffraction using a multi-anvil press (MAP) with synchrotron radiation. The MCC consists of multiple channels of collimators in a radial alignment. This eliminates diffraction from the materials surrounding the sample so that we can obtain high-quality diffraction from samples in a MAP using an imaging plate. We have installed a MCC system on a MAP named MAX90 at the Photon Factory, National Laboratory for High Energy Physics. Performance of the MCC has been satisfactorily evaluated, and diffraction patterns of liquid sodium and liquid gallium under 4.8 GPahave been succesfully obtained using this system.

2 (Records 1-2 displayed on this page)
  • 1