Refine your search:     
Report No.
 - 
Search Results: Records 1-7 displayed on this page of 7
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

New field of actinides solution chemistry; Electrochemical study on actinide ion Transfer at the Interface of two immiscible electrolyte solutions

Kitatsuji, Yoshihiro; Yoshida, Zenko; Kudo, Hiroshi*; Kihara, Sorin*

Analytical Sciences (CD-ROM), 17(Suppl.), p.329 - 331, 2002/03

no abstracts in English

Journal Articles

Voltammetric study on transfer of UO$$_{2}^{2+}$$ across the interface between aqueous and nitrobenzene solutions in the presence of Octyl(phenyl)-N,N-diisobutylcarbamoyl-methyl-phosphine oxide (CMPO)

Ying, M.*; Kitatsuji, Yoshihiro; Kimura, Takaumi; Yoshida, Zenko

Journal of Nuclear and Radiochemical Sciences, 2(1-2), p.11 - 15, 2001/12

no abstracts in English

JAEA Reports

Measurement of U and Pu concentration by X-ray fluorescence spectrometry using vertical irradiation system.

; ; ; Ikeda, Hisashi ; Jitsukata, Shu*;

JNC TN8410 2000-022, 55 Pages, 2000/05

JNC-TN8410-2000-022.pdf:1.57MB

Measurement of U and Pu concentrations by wavelength dispersion type X-ray fluorescence spectrometry was studied. Sample holder was installed inside of glove box and other instruments, X-ray tube, monochromator and detectors were set out side of the glove box. X-rays was irradiated to sample though Be window. Fluorescent X-rays form sample were also passing though the same Be window and detected outside. Analytical conditions were optimized as follows. Sample thickness is 8 mm, which is 3ml of sample volume by the sample holder. Voltage and eurrent for X-ray tube is 50kV and 40 mA, respectively. Measurement was done twice, 60 seconds each, and averaged X-ray intensity was used to calculate elemental concentrations. Matrix correction was necessary to measure U and Pu concentration within 10% accuracy. Detection limits were calculated to 0.4 mg/L for U and 0.7mg/L for Pu. Calibration curve was liner up to 9 g/L fbr U and Pu. Two calculation methods, calibration curve method and standard addition method, were studied to measure Pu concentration in organic solution. Detection limit was 5.3 mg/L and 0.2 mg/L, respectively.

Journal Articles

Voltammetric study on ion transfer of uranium(VI) ion between aqueous and nitrobenzene phases in the presence of bis(diphenylphosphoryl) methane

Kitatsuji, Yoshihiro; Aoyagi, Hisao; Yoshida, Zenko; Kihara, Sorin*

Analytical Sciences, 14, p.67 - 70, 1998/02

 Times Cited Count:11 Percentile:38.76(Chemistry, Analytical)

no abstracts in English

Journal Articles

Simulation study on behavior of technetium and its controlled strip during codecontamination process of fuel reprocessing

Tachimori, Shoichi

Journal of Nuclear Science and Technology, 31(5), p.456 - 462, 1994/05

 Times Cited Count:5 Percentile:47.57(Nuclear Science & Technology)

no abstracts in English

JAEA Reports

Autoxidations of Benzene and Toluene in the Aqueous Phase

Hotta, Hiroshi

JAERI 1185, 53 Pages, 1969/10

JAERI-1185.pdf:3.25MB

no abstracts in English

7 (Records 1-7 displayed on this page)
  • 1