森下 祐樹; 金子 純一*; 樋口 幹雄*; 井崎 賢二; 矢島 辰雄*; 松浦 貢*; 田村 健; 鳥居 建男
Radiation Measurements, 122, p.115 - 120, 2019/03
被引用回数:8 パーセンタイル:65.31(Nuclear Science & Technology)A dust monitor with a silicon surface barrier detector (SSBD) is introduced at a nuclear fuel facility to detect airborne contamination of Pu and Pu released by past accidents. However, an SSBD frequently produces false alarms, especially in a room with high humidity. We developed an alpha-particle spectrometer based on a cerium-doped GdSiO (GPS) scintillator plate and a photomultiplier tube (PMT). The energy resolution for 5.5-MeV alpha particles was 11.9% 0.2% of the FWHM. The efficiency was 92%, and it had a uniform sensitivity. By applying an energy window, the count-rate of the Rn progeny decreased by 77%. The GPS scintillator plate was able to measure the alpha spectrum even though the GPS scintillator got wet.
森下 祐樹; 金子 純一*; 井崎 賢二; 矢島 辰雄*; 松浦 貢*
no journal, ,
事故時に放出されるPuやPuの空気汚染の検知のため、シリコン半導体検出器を用いたダストモニタが原子力施設に設置されている。しかし、このダストモニタは誤警報を頻発していた。高信頼のダストモニタの開発のため、GPSシンチレータとPMTを用いた線スペクトロメータを開発した。5.5MeV線に対するエネルギー分解能を評価した結果11.9% FWHMであった。ラドン子孫核種の除去率はZnS(Ag)シンチレータを用いた線スペクトロメータより向上した。今後開発したスペクトロメータは高信頼のダストモニタへの応用が期待できる。
佐藤 里奈; 吉村 和也; 眞田 幸尚; 矢島 千秋*; 青野 辰雄*
no journal, ,
空間線量率と生活行動を考慮して被ばく線量を精度良く推計するシミュレーション手法の構築を目的として、2種類の被ばく線量シミュレーションシステムの各推計値と個人線量計の実測値を比較し、外部被ばく線量の推計に寄与するパラメータの検証を行った。福島第一原子力発電所事故で影響を受けた自治体に居住・就労する成人に対し2020年に取得した生活行動データおよび個人線量計測定データを用いて比較した結果、各推計値は実測値と有意な相関を示した。また、本研究では屋外空間線量率が推計誤差に最も寄与していた。