Zito, P.*; Lampasi, A.*; Coletti, A.*; Novello, L.*; 松川 誠; 島田 勝弘; Cinarelli, D.*; Portesine, M.*; Dorronsoro, A.*; Vian, D.*
Fusion Engineering and Design, 98-99, p.1191 - 1196, 2015/10
被引用回数:13 パーセンタイル:71.17(Nuclear Science & Technology)In JT-60SA, Fast Plasma Position Control Coils Power Supplies (FPPCC PSs) control vertical position of the plasma during a plasma shot, against Vertical Displacements Event (VDE). For this task, the FPPCC PSs have to be as fast as possible and provide as much voltage as possible. Further, these will be open loop feed forward voltage controlled. The main characteristics are: 4-quadrant AC/DC converter 12-pulse with circulating current, DC load voltage 1000 V and DC load current 5 kA. The induced overvoltage in FPPC coil during a plasma disruption can reach 10 kV and it is bounded by a nonlinear resistor in parallel to the crowbar. All these technical characteristics have strongly influenced the design of the FPPC converter and of the FPPC transformers, that have been validated by simulation model of FPPCC PS. The outcomes of the simulation have allowed to finalize the performances and dynamic behavior of voltage response.
Zito, P.*; Lampasi, A.*; Novello, L.*; 松川 誠; 島田 勝弘; Portesine, M.*; Fasce, F.*; Cinarelli, D.*; Dorronsoro, A.*; Vian, D.*
Proceedings of IEEE 15th International Conference on Environment and Electrical Engineering (IEEE-EEEIC 2015), p.156 - 160, 2015/06
In JT-60SA, Fast Plasma Position Control Coils (FPPCC) PSs allow controlling the vertical position of the plasma during a plasma shot, against Vertical Displacements Event (VDE). An open loop feed forward voltage control is adopted in order to achieve a fast control of FPPCC PSs. The characteristics of the PS are: 4-quadrant AC/DC converter 12-pulse, DC load voltage 1000 V and DC load current 5 kA. The design of the FPPCC converters has been validated by a simulation model, finalizing the performances and dynamic behavior of voltage response. After the completion of the realization phase, the testing phase has been carried out in accordance to the IEC60146 Standards and this is the focus of the paper. The tests performed have pointed out a good dynamic behavior of the FPPCC converter in open loop feed forward voltage control, for a reference voltage step of 1kV, the rise time of output voltage is 2.88 ms, confirming outcomes achieved by simulations.