検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 2 件中 1件目~2件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Establishment of a low dose rate gamma ray calibration field for environmental radiation monitoring devices

古渡 意彦; 吉富 寛; 西野 翔; 谷村 嘉彦; 大石 哲也; Kessler, P.*; Neumaier, S.*; R$"o$ttger, A.*

Radiation Protection Dosimetry, 187(1), p.61 - 68, 2019/12

 被引用回数:1 パーセンタイル:58.8(Environmental Sciences)

A low dose rate Cs gamma ray calibration field that fully satisfies the requirement of the ISO 4037 series was established in the Facility of Radiation Standards in Japan Atomic Energy Agency. Two different methods were employed to determine the reference air kerma rate, namely a conventional ionization chamber and a G(E) function method used a newly developed scintillation spectrometer. To fulfill the requirement of the ISO 4037 and suppress scattering of Cs gamma ray within the room as far as possible, a suitable lead collimator was introduced to limit the irradiation area at test points and placed at the middle height in an irradiation room with a grating floor. From measured results evaluated reference air kerma rates between 1.0 m and 3.0 m from the center of the source, gamma ray scattering from the room structures was found to be negligible. The resulting Cs gamma ray calibration field could provide ambient dose equivalent rates of 0.7-7.2 $$mu$$Sv h$$^{-1}$$ for use with environmental radiation monitoring devices.

論文

Corrigendum; Establishment of a low dose rate gamma ray calibration field for environmental radiation monitoring devices

古渡 意彦; 吉富 寛; 西野 翔; 谷村 嘉彦; 大石 哲也; Kessler, P.*; Neumaier, S.*; R$"o$ttger, A.*

Radiation Protection Dosimetry, 186(4), P. 538, 2019/12

 被引用回数:0 パーセンタイル:100(Environmental Sciences)

原著論文の表5(B)中の単位について、nSv h$$^{-1}$$とすべきところ$$mu$$Sv h$$^{-1}$$と記載するミスがあったため、訂正する。

2 件中 1件目~2件目を表示
  • 1