検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 2 件中 1件目~2件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Repetition Rate Multiplication: RRM, an advanced measuring method planed for the backscattering instrument, ${it DNA}$ at the MLF, J-PARC

高橋 伸明; 柴田 薫; 川北 至信; 中島 健次; 稲村 泰弘; 中谷 健; 中川 洋; 藤原 悟; 佐藤 卓*; 筑紫 格*; et al.

Journal of the Physical Society of Japan, 80(Suppl.B), p.SB007_1 - SB007_4, 2011/12

 被引用回数:6 パーセンタイル:43.42(Physics, Multidisciplinary)

A TOF-BSS named ${it DNA}$ has been under construction on BL02 in the MLF of J-PARC. We have estimated expected performances of several candidates under realistic neutron source parameters at MLF. The expected neutron intensity under comparable energy resolutions of the ${it DNA}$-type is 2.6 times higher than that of the BASIS-type. Consequently, we have chosen the CM with pulse-shaping device for ${it DNA}$. Pulse-shaping is a good technique from a view point of a variability of resolution. On the other hand, a neutron energy band passing through the pulse-shaping chopper is limited and thus scanning range with one phase of the chopper is narrow. Of course, ${it DNA}$ also can access larger energy transfers by appropriate phasing of the pulse-shaping chopper. In addition, ${it DNA}$ will be able to utilize Repetition Rate Multiplication (RRM). RRM is essentially a way to employ multiple pulse-shaped incident neutron beams to effectively increase neutron counting time to more efficiently measure the inelastic region. In this presentation we will show the chopper sequence and introduce the RRM mode of the forthcoming backscattering spectrometer ${it DNA}$ in detail.

口頭

Current status of the Si crystal analyzer near backscattering TOF spectrometer DNA in a spallation neutron source at J-PARC

高橋 伸明; 柴田 薫*; 山田 武*; 蒲沢 和也*; 川北 至信; 中島 健次; 神原 理; 稲村 泰弘; 中谷 健; 相澤 一也; et al.

no journal, , 

A Si crystal analyzer near backscattering spectrometer DNA which covers the area of the micro-eV energy range in the Q-E space, where it is expected to explore sciences on atomic, molecular and spin dynamics in the nanosecond time range has been installed at BL02 of the Materials and Life Science Experimental Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC) until at the end of February 2012. Then, various on-beam commissioning has been done for about a year with handling continuing user program. In this report, we will introduce specifications, current status of the instrument.

2 件中 1件目~2件目を表示
  • 1