Neutron transmission CB-KID imager using samples placed at room temperature

石田 武和*; Vu, TheDang*; 宍戸 寛明*; 相澤 一也; 奥 隆之; 及川 健一; 原田 正英; 小嶋 健児*; 宮嶋 茂之*; 小山 富男*; et al.

Journal of Low Temperature Physics, 214(3-4), p.152 - 157, 2024/02

We built a new cryostat to apply a current-biased kinetic inductance detector (CB-KID) for conducting neutron transmission imaging of room temperature samples under pulsed neutrons. A Wood's metal alloy of melting temperature 75.2$$^{circ}$$C was placed at room temperature to inspect the measurement system at J-PARC. Since one of the four phases of Wood's metal is a fine Cd-rich needle phase (width $$sim$$ 25 $$mu$$m and length $$sim$$ 5 mm), it is suitable for observing fine mosaic structure selectively by neutron imaging. The spatial resolution of the CB-KID imager was estimated as $$sim$$ 10 $$mu$$m by using a Gd Siemens-star pattern. The CB-KID system is useful to conduct transmission imaging for various materials rather easily at room temperature.

論文

Orientation mapping of YbSn$$_{3}$$ single crystals based on Bragg-dip analysis using a delay-line superconducting sensor

宍戸 寛明*; Vu, TheDang*; 相澤 一也; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 奥 隆之; 曽山 和彦; 宮嶋 茂之*; et al.

Journal of Applied Crystallography, 56(4), p.1108 - 1113, 2023/08

Recent progress in high-power pulsed neutron sources has stimulated the development of the Bragg dip and Bragg edge analysis methods using a two-dimensional neutron detector with high temporal resolution to resolve the neutron energy by the time-of-flight method. A delay-line current-biased kinetic inductance detector (CB-KID) is a two-dimensional superconducting sensor with a high temporal resolution and multi-hit capability. Here, it is demonstrated that a delay-line CB-KID with a $$^{10}$$B neutron conversion layer can be applied to high-spatial-resolution neutron transmission imaging and spectroscopy up to 100 eV. Dip structures are observed in the transmission spectra of YbSn$$_{3}$$ single crystals, induced by Bragg diffraction and nuclear resonance absorption. The orientation mapping of YbSn$$_{3}$$ crystals is successfully drawn based on the analysis of observed Bragg dip positions in the transmission spectra.

論文

High spatial resolution neutron transmission imaging using a superconducting two-dimensional detector

宍戸 寛明*; 西村 和真*; Vu, TheDang*; 相澤 一也; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 奥 隆之; 曽山 和彦; et al.

IEEE Transactions on Applied Superconductivity, 31(9), p.2400505_1 - 2400505_5, 2021/12

 被引用回数:0 パーセンタイル:0(Engineering, Electrical & Electronic)

中性子イメージングは、重金属に対する高透過性、軽元素に対する高感度、同位体と中性子との特異な核反応による同位体選択性などの中性子ビームの特徴を活かした非破壊検査の有力な手段の一つである。本研究では、超伝導検出器である電流バイアス運動インダクタンス検出器(CB-KID)を用いて、パルス中性子源を用いた飛行時間法による波長分解中性子イメージングを行った。遅延時間型CB-KIDを用いて、GdAl$$_{3}$$単結晶を成長させたGd-Al合金試料の中性子透過像を取得した。その結果、単結晶はAl-Gd合金全体に渡って、形状,分布ともに良好に観察することができた。また、中性子の波長0.03nm以上でGdによる特徴的な中性子の吸収を確認した。さらに、15$$mu$$m$$ times$$ 12$$mu$$mという限られた検出面で、同位体と中性子の核反応によって生じる$$^{155}$$Gd共鳴ディップを観測することができた。また、$$^{155}$$Gdの共鳴ディップを用いてGd選択的イメージングを行ったところ、中性子の波長幅が1pmという限られた範囲で、明確なGd核の元素選択イメージング像を取得することに成功した。

論文

Practical tests of neutron transmission imaging with a superconducting kinetic-inductance sensor

Vu, TheDang; 宍戸 寛明*; 相澤 一也; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 奥 隆之; 曽山 和彦; 宮嶋 茂之*; et al.

Nuclear Instruments and Methods in Physics Research A, 1006, p.165411_1 - 165411_8, 2021/08

 被引用回数:0 パーセンタイル:0.02(Instruments & Instrumentation)

We found that the sizes of the Gd islands determined from the transmission image correlated strongly with those determined from the SEM image. We demonstrated the CB-KID could be used to identify (1) tiny voids in a thermally sprayed continuous Gd$$_2$$O$$_3$$ film in and (2) various mosaic morphologies and different eutectic microstructures in Wood's metal samples. The fact that the CB-KID system could be used to identify features of samples with a wide distribution of sizes and thicknesses is promising for real application of the device for imaging samples of interest to material scientists. Operating the CB-KID at higher temperatures appreciably improved the efficiency for simultaneously identifying the X and Y positions of hotspots. We also compared the detection efficiency with the PHITS simulations. We now plan to improve the detection efficiency by increasing the thickness of the $$^{10}$$B neutron conversion layer

論文

Homogeneity of neutron transmission imaging over a large sensitive area with a four-channel superconducting detector

Vu, TheDang; 宍戸 寛明*; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 宮嶋 茂之*; 奥 隆之; 曽山 和彦; 相澤 一也; et al.

Superconductor Science and Technology, 34(1), p.015010_1 - 015010_10, 2021/01

 被引用回数:3 パーセンタイル:28.82(Physics, Applied)

We demonstrated that a four-readout superconducting neutron imaging system shows good spatial heterogeneity and linearity using the delay-line method. We examined the precise pattern of a $$^{10}$$B-dot-array absorber and found the X-direction pitch (Px) = 250.7 um with a scatter of (Hx)= 5.4 um and the Y-direction pitch (Py)= 249.1 um with a scatter of (Hy)= 3.4 um while the $$^{10}$$B dot array was fully extended toward the X direction across the detector sensitive area. We consider that this demonstrates detection with good spatial homogeneity and conclude. The transmission-imaging system is suitable for use at pulsed neutron facilities. We also reported a clear transmission image of tiny screws and nuts, and ladybug (insect). We recognize that further efforts to improve the detection efficiency are necessary to make using the detector more practical.

論文

Energy-resolved neutron imaging using a delay line current-biased kinetic-inductance detector

宍戸 寛明*; 西村 和真*; Vu, TheDang*; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 宮嶋 茂之*; 日高 睦夫*; 奥 隆之; et al.

Journal of Physics; Conference Series, 1590, p.012033_1 - 012033_8, 2020/10

We demonstrate the development of an energy resolved neutron transmission imaging system via a solid-state superconducting detector, called current-biased kinetic-inductance detector (CB-KID). CB-KIDs comprise X and Y superconducting Nb meanderlines with Nb ground plane and a $$^{10}$$B conversion layer, which converts a neutron to two charged particles. CB-KID uses the delay-line method, and allows us to reconstruct the two-dimensional neutron transmission image of a test sample with four signal readout lines. We examined the capability of high spatial and energy (wavelength) resolved neutron transmission imaging over the sensor active area of 15 $$times$$ 15 mm$$^{2}$$ for various samples, including biological and metal ones. We also demonstrated the capability for the Bragg edge transmission and an energy-resolved neutron image in which stainless-steel specimens were discriminating from other specimens.

論文

Kinetic inductance neutron detector operated at near critical temperature

Vu, TheDang; 西村 和真*; 宍戸 寛明*; 原田 正英; 及川 健一; 宮嶋 茂之*; 日高 睦夫*; 奥 隆之; 曽山 和彦; 相澤 一也; et al.

Journal of Physics; Conference Series, 1590, p.012036_1 - 012036_9, 2020/07

 被引用回数:0 パーセンタイル:0.01

Our CB-KID neutron imager detects high spatial resolution neutrons transmission images by using a delay-line technique. We found that the number of events was remarkably increased with increasing the detector temperature until close to the critical temperature Tc. We investigated the properties of CB-KID at near Tc. We observed systematic changes of neutron signals as a function of the detector temperature from 4 K to Tc. The simulations modeled the sequential physical processes for $$^{10}$$B(n,$$alpha$$)$$^{7}$$Li reactions and energy deposition by particles within CB-KID, including neutrons, $$^{4}$$He particles, $$^{7}$$Li particles, photon and electron transport.

論文

Energy-resolved neutron imaging with high spatial resolution using a superconducting delay-line kinetic inductance detector

飯澤 侑貴*; 宍戸 寛明*; 西村 和真*; Vu, TheDang*; 小嶋 健児*; 小山 富男*; 及川 健一; 原田 正英; 宮嶋 茂之*; 日高 睦夫*; et al.

Superconductor Science and Technology, 32(12), p.125009_1 - 125009_8, 2019/12

 被引用回数:11 パーセンタイル:56.9(Physics, Applied)

Neutron imaging is one of the key technologies for non-destructive transmission testing. Recent progress in the development of intensive neutron sources allows us to perform energy-resolved neutron imaging with high spatial resolution. We have been developing a neutron imager aiming at conducting high spatial and temporal resolution imaging based on a delay-line neutron detector, called the current-biased kinetic-inductance detector, with a conversion layer $$^{10}$$B. The detector allowed us to obtain a neutron transmission image with four signal readout lines. Herein, we expanded the sensor active area, and improved the spatial resolution of the detector. We examined the capability of high spatial resolution neutron imaging over the sensor active area of 15 $$times$$ 15 mm$$^{2}$$ for various samples, including biological and metal ones. We also demonstrated an energy-resolved neutron image in which stainless-steel specimens were discriminating of other specimens with the aid of the Bragg edge transmission.

論文

Temperature dependent characteristics of neutron signals from a current-biased Nb nanowire detector with $$^{10}$$B converter

Vu, TheDang; 飯澤 侑貴*; 西村 和真*; 宍戸 寛明*; 小嶋 健児*; 及川 健一; 原田 正英; 宮嶋 茂之*; 日高 睦夫*; 奥 隆之; et al.

Journal of Physics; Conference Series, 1293, p.012051_1 - 012051_9, 2019/10

 被引用回数:5 パーセンタイル:93.54

We succeeded in designed and fabricated a neutron detector by using a superconducting current-biased kinetic inductance detector (CB-KID), which is constructed by two perpendicular Nb-based superconducting meander-lines and an enriched $$^{10}$$B neutron conversion layer. We rebuilt completely a neutron image of a $$^{10}$$B dot array contain in the stainless-steel mesh. To improve the resolution of neutron images, the characteristics of a superconducting neutron detector have been studied carefully. In this study, we present the dependence of neutron signals in the temperature of detector. We found that when the temperature of a neutron detector is as close as the critical temperature of superconductivity, the intensity of signal increase as a function of temperature. We consider that the ratio of noise and signal is decrease which is very useful to improve the resolution of neutron images.

論文

Neutron flux spectrum revealed by Nb-based current-biased kinetic inductance detector with a $$^{10}$$B conversion layer

宮嶋 茂之*; 宍戸 寛明*; 鳴神 吉人*; 吉岡 直人*; 藤巻 朗*; 日高 睦夫*; 及川 健一; 原田 正英; 奥 隆之; 新井 正敏*; et al.

Nuclear Instruments and Methods in Physics Research A, 842, p.71 - 75, 2017/01

 被引用回数:13 パーセンタイル:78.46(Instruments & Instrumentation)

We successfully derived the time-dependent flux of pulsed neutrons using a superconducting Nb-based current biased kinetic inductance detector (CB-KID) with a $$^{10}$$B conversion layer at Japan Proton Accelerator Research Complex. Our CB-KID is a meander line made of a 40-nm-thick Nb thin film with 1-$$mu$$m line width, which is covered with a 150-nm-thick $$^{10}$$B conversion layer. The detector works at a temperature below 4 K. The evaluated detection efficiency of the CB-KID in this experiment is 0.23% at the neutron energy of 25.4 meV. The time-dependent flux spectra of pulsed neutrons thus obtained are in good agreement with the results obtained by the Monte Carlo simulations.