検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 11 件中 1件目~11件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Evaluation of ductile damage progress of aluminum single crystal with prior activity of single slip system under tensile loading by using synchrotron white X-ray

柴野 純一*; 梶原 堅太郎*; 塚本 拓也*; 河合 紘和*; 三浦 節男*; Zhang, S.*; 菖蒲 敬久; 小林 道明*

Materials Science Forum, 777, p.176 - 181, 2014/02

 被引用回数:1 パーセンタイル:53.76(Materials Science, Multidisciplinary)

A ductile damage progress of an aluminum single crystal with the prior activity of the single slip system under tensile loading was verified by a profile analysis using white X-ray obtained in BL28B2 beam line of SPring-8. In this study, the aluminum single crystal of the purity 6N was used as a specimen prepared in I-type geometry for tensile test. In profile analysis, an instrumental function was defined in consideration both of a divergence by a slit and a response function peculiar to the energy dispersive method. The Gauss component of integral breadth related to non-uniform strain and the Cauchy component of integral breadth related to crystallite size were determined by eliminating the broadening by the instrumental function from the diffraction profile of white X-ray. As a result, the characteristics of ductile damage progress near the notch of the aluminum single crystal were inspected from the distribution of both non-uniform strain and dislocation density.

論文

アルミニウム単結晶延性損傷評価のための放射光白色X線による検討

柴野 純一*; 木曽 稔*; 梶原 堅太郎*; 菖蒲 敬久; 三浦 節男*; 小林 道明*

材料, 62(7), p.443 - 450, 2013/07

FCC単結晶の延性損傷の進展と結晶方位の関係を実験的に検証するにはX線回折法が有効である。本研究では、アルミニウム単結晶を塑性域まで引張変形させ、結晶内部から得られた透過回折X線プロファイルから不均一ひずみや転移密度分布を評価した。その結果、負荷ひずみが1.1%の段階でノッチ底から斜め約45$$^{circ}$$の方向にひずみの増大が見られたが、2.2%の段階ではノッチ底から斜め45$$^{circ}$$方向に格子ひずみの減少が確認された。そして、これらとプロファイル解析の結果から、[001]方位が引張負荷方向を向いたアルミニウム単結晶のノッチ近傍の不均一ひずみ分布と転位密度分布から、延性損傷の進展方向とその特徴を明らかにした。

論文

Transmission imaging and strain mapping in the vicinity of internal crack tip using synchrotron white X-ray

柴野 純一*; 梶原 堅太郎*; 桐山 幸治*; 菖蒲 敬久; 鈴木 賢治*; 西村 優*; 三浦 節男*; 小林 道明*

Materials Science Forum, 638-642, p.2476 - 2481, 2010/01

A transmission imaging and a strain mapping in the vicinity of a crack tip in steel were investigated using a high energy white X-ray obtained from BL28B2 beam line at SPring-8 in Japan. Low-alloy and high-tensile steel was used as a specimen prepared in the G-type geometry with a rectangular sectional part of 5 mm thickness for a four-point bending. As the results, the transmitted image of the crack showed that the crack in the specimen was propagated deeper than that on the surface. It became clear by the numerical simulation that the FWHM of diffracted X-ray profile measured near the crack tip was increased due to the steep change in the strain distribution. It was confirmed that the synchrotron white X-ray was useful for the imaging of the internal crack and the strain mapping near it.

論文

放射光白色X線を用いたCTによる丸棒鋼内部き裂の観察とその先端近傍のひずみマッピング

柴野 純一*; 桐山 幸治; 梶原 堅太郎*; 菖蒲 敬久; 鈴木 賢治*; 新居 恭征*; 三浦 節男*; 小林 道明*

材料, 58(7), p.596 - 602, 2009/07

A computerized tomography and a strain mapping near a crack tip in material were investigated using a white X-ray obtained from BL28B2 beam line at SPring-8 in Japan. The computerized tomography of the crack in the specimen was carried out by using the CCD camera that can detect indirectly the X-ray transmitted through the specimen. To measure the strain using the energy dispersive X-ray diffraction technique. As the results, the computerized tomography of the crack in the specimen under the tensile loading was practicable by using the white X-ray. The map of the internal strain near the crack tip of the specimen could be obtained using the high energy white X-ray. It was confirmed that the maximum tensile strain was distributed circularly along the crack tip estimated by CT.

論文

放射光白色X線による内部き裂先端近傍のイメージングとひずみマッピングの検討

柴野 純一*; 梶原 堅太郎*; 桐山 幸治; 菖蒲 敬久; 鈴木 賢治*; 西村 優*; 三浦 節男*; 小林 道明*

材料, 57(7), p.667 - 673, 2008/07

An imaging and a strain mapping in the vicinity of crack tip in materials were investigated using high energy white X-ray obtained from BL28B2 beam line at SPring-8 Japan. Low-alloy and high-tensile steel (JIS G3128 SHY685) was used as a specimen shaped into G-type and introduced a fatigue crack into the beam of it. As the results, the imaging of the crack of the length of about 1mm in the specimen with loading of crack opening is practicable by using high energy synchrotron white X-ray. The plastic region estimated from the distribution of FWHM almost agreed with the theoretical value calculated by fracture mechanics. It was confirmed that the high energy white X-ray was useful for the imaging of the crack and the strain mapping in the vicinity of it in the depth of the order of millimeter.

論文

Measurement of internal strain in materials using high energy white X-ray at SPring-8

柴野 純一*; 菖蒲 敬久; 鈴木 賢治*; 桐山 幸治; 梶原 堅太郎*; 金子 洋; 小林 道明*

Materials Science Forum, 571-572, p.267 - 270, 2008/00

In this paper, the strain in the bulk of material was measured using high energy white X-rays from synchrotron radiation sources of BL14B1 and BL28B2 at SPring-8 in Japan. JIS-S45C carbon steel and JIS-SHY685 high-tensile steel were used as specimens. As a result, the internal strain of SHY685 of 15 millimeters thickness could be evaluated using X-rays with energy of 155 keV diffracted by $$alpha$$-Fe321 lattice plane. It is suitable for the high accuracy measurement to include more than or equal to 5000 grains of crystal in the gauge volume. Furthermore, the measurement error peak count and the profile which is close to Gaussian curve. However, the measurement accuracy of the internal strain of S45C was relatively low. Because the diffracted X-ray peak counts at each measurement position fluctuated with the relationship between grain size of S45C and the irradiated X-ray beam size.

論文

高エネルギー放射光白色X線を用いた材料内部ひずみ測定

柴野 純一*; 菖蒲 敬久; 鈴木 賢治*; 平田 智之*; 金子 洋; 小林 道明*

材料, 56(10), p.985 - 992, 2007/10

高エネルギー白色X線を用いた応力測定技術開発を原子力機構専用ビームラインを用いて行った。鉄鋼材の1つであるWEL-TEN780E(JIS G3128 SHY685)に負荷ひずみを加えた状態で内部ひずみをエネルギー分散法により測定した結果、マクロひずみとほぼ同等なひずみを求めることに成功した。特に本手法では、50$$mu$$m程度の微小領域のひずみを求めることができることから、今後き裂先端などの局所ひずみを求めるなどの応用が期待される。

口頭

放射光白色X線を用いた鉄鋼材料内部のき裂イメージングと応力マッピング

桐山 幸治; 柴野 純一*; 梶原 堅太郎*; 菖蒲 敬久; 鈴木 賢治*; 金子 洋; 西村 優*; 新居 恭征*; 三浦 節男*; 小林 道明*

no journal, , 

鉄鋼材料の応力腐食割れ(Stress Corrosion Cracking: SCC)の機構解明には、溶接部近傍に内在する残留応力とそこで発生するき裂の進展状況を理解することが重要である。そこで、本研究では、SPring-8のビームラインBL14B1及びBL28B2において高エネルギー放射光白色X線を用いて人工的にき裂をいれた鉄鋼材料のき裂周辺部のイメージングと内部応力測定を行った。その結果、有負荷時のき裂開放状態において、イメージング画像によって試料内部のき裂を観察することができた。また、き裂周辺部の内部ひずみ分布を測定したところ、イメージング画像と整合のある結果が得られた。これより放射光白色X線を用いたイメージング技術と内部ひずみ測定技術を組合せて、総合的に解析することで鉄鋼材料の内部状態の理解に大変有効であるということがわかった。

口頭

放射光白色X線CTを用いた鉄鋼材料内部疲労き裂分布の詳細観察

桐山 幸治; 柴野 純一*; 梶原 堅太郎*; 菖蒲 敬久; 鈴木 賢治*; 新居 恭征*; 三浦 節男*; 小林 道明*

no journal, , 

溶接部近傍で発生する鉄鋼材料の応力腐食割れの機構を解明するためにはき裂の進展具合と溶接部近傍の内部ひずみ分布を非破壊で測定する必要がある。本研究では、SPring-8のビームラインBL28B2において高エネルギー放射光白色X線を用いて人工的にき裂をいれた鉄鋼材料のCTスキャンを行った。その結果、CTによって有負荷時のき裂開放状態において試料内部のき裂が明確に観察することができた。また、そのデータを元にき裂周辺部の内部ひずみ分布を測定したところ、CT画像と整合のある分布結果が得られた。これより放射光白色X線を用いたCT技術は、内部ひずみ測定技術を組合せることで鉄鋼材料の内部状態の理解に大変有効であるということがわかった。

口頭

Study of computerized tomography and strain mapping in the vicinity of crack tip in steel material using synchrotron white X-ray

柴野 純一*; 梶原 堅太郎*; 桐山 幸治; 菖蒲 敬久; 鈴木 賢治*; 新居 恭征*; 三浦 節男*; 小林 道明*

no journal, , 

A computerized tomography and a strain mapping in the vicinity of a crack tip in steel were investigated using a high energy white X-ray obtained from BL28B2 beam line at SPring-8 in Japan. Low-alloy and high-tensile steel (JIS G3128 SHY685) was used as a specimen prepared in the cylindrical geometry. A fatigue crack was introduced into the specimen by a cyclic loading. As the results, the computerized tomography of the crack in the specimen under the loading of crack opening was practicable by using the synchrotron white X-ray. The contour map of the internal strain near the crack tip of the steel of 5mm diameter could be obtained using the white X-ray with energy ranging from 50keV to 150keV. It was confirmed that the synchrotron white X-ray is useful for the computerized tomography of the internal crack and the strain mapping near it.

口頭

5mm径鋼棒内部き裂の放射光白色X線CTによる検出とひずみ分布測定

柴野 純一*; 桐山 幸治; 梶原 堅太郎*; 菖蒲 敬久; 鈴木 賢治*; 新居 恭征*; 三浦 節男*; 小林 道明*

no journal, , 

高エネルギー白色X線を用いて、疲労き裂を導入した5mm径の鉄棒内部CT観察及びひずみ分布測定を実施した。その結果、内部に広がるき裂の形状、及びその周りに広がるひずみ分布を非破壊で測定することに成功した。

11 件中 1件目~11件目を表示
  • 1