論文

X線イメージングを用いた球充填層内のボイド率分布計測

山本 誠士郎*; 大平 直也*; 伊藤 大介*; 伊藤 啓*; 齊藤 泰司*; 今泉 悠也; 松場 賢一; 神山 健司

混相流, 37(1), p.79 - 85, 2023/03

In the safety study on a sodium-cooled fast reactor, it is assumed that the high temperature fuel debris are formed because of a core disruptive accident. During the cooling of the fuel debris, gas-liquid two-phase flow can be generated in the debris due to the coolant boiling. To improve the prediction accuracy of the flow characteristics, detailed measurement of the gas-liquid two-phase flow in the debris bed is required. In this study, gas-liquid two-phase flow in a quasi-two-dimensional sphere-packed bed, which simulates the debris bed, is visualized by using X-ray imaging. The experimental results show that the local void fraction increases near the splitting section in the packed bed and decreases near the coalescence section.

論文

Measurements of pressure drop and void fraction of air-water two-phase flow in a sphere-packed bed

山本 誠士郎*; 大平 直也*; 伊藤 大介*; 伊藤 啓*; 齊藤 泰司*; 今泉 悠也; 松場 賢一; 神山 健司

Proceedings of 12th Japan-Korea Symposium on Nuclear Thermal Hydraulics and Safety (NTHAS12) (Internet), 4 Pages, 2022/10

To develop a microscopic pressure drop prediction model based on detailed measurement data of gas liquid two-phase flow, the pressure drop was measured in the vertical upward gas-liquid two-phase flow formed in quasi-2D test section. The measurement results showed that the pressure drop in the quasi-2D test section was much smaller than that in the ordinal packed bed system, which suggests that the pressure drop mechanism in the quasi-2D test section could be different from that in the ordinal packed bed system due to differences in two-phase flow characteristics in the two systems. The void fraction distribution was also measured in the quasi-2D test section by the X-ray imaging technique, which revealed that there was a local distribution of the void fraction in the channel unit structure of the closest packed bed.

口頭

ナトリウム冷却高速炉における損傷炉心内の冷却材挙動に関する研究,7; 模擬デブリ内における気液二相流の局所流動評価

大平 直也*; 山本 誠士郎*; 伊藤 大介*; 伊藤 啓*; 齊藤 泰司*; 今泉 悠也; 松場 賢一; 神山 健司

no journal, , 

球充填層内の複雑流路を流れる気液二相流の局所的な挙動を明らかにするため、中性子によるボイド率分布の計測を行った。その結果、流路が細い先端部には気相がほとんど存在せず、流路中央部に気相が集中して分布することが明らかになった。