Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
岸本 俊二*; 三井 隆也; 春木 理恵*; 依田 芳卓*; 谷口 敬*; 島崎 昇一*; 池野 正弘*; 斉藤 正俊*; 田中 真伸*
Journal of Instrumentation (Internet), 10(5), p.C05030_1 - C05030_6, 2015/05
被引用回数:6 パーセンタイル:28.47(Instruments & Instrumentation)We developed an X-ray detector system using a 64-pixel silicon avalanche photodiode Si-APD linear array and fast pulse-counting electronics for multichannel scaling. The Si-APD linear array consists of 64 pixels each 0.010.02 cm in size, with a pixel pitch of 0.015 cm and depletion depth of 0.001 cm. The fast electronics, consisting of an ultrafast application-specific integrated circuit and field-programmable gate arrays, can record both the position and timing of X-rays arriving at each pixel of the linear array with 1 ns pulse-pair resolution. The count distribution was measured using 14.4 keV synchrotron X-rays for nuclear resonant forward scattering experiments on Fe, and the spatial resolution was improved by inclining the detector. We also successfully measured amorphous alloy FeSiB during heating.
岸本 俊二*; 三井 隆也; 春木 理恵*; 依田 芳卓*; 谷口 敬*; 島崎 昇一*; 池野 正弘*; 斉藤 正俊*; 田中 真伸*
Review of Scientific Instruments, 85(11), p.113102_1 - 113102_5, 2014/11
被引用回数:8 パーセンタイル:36.91(Instruments & Instrumentation)We developed a silicon avalanche photodiode (Si-APD) linear-array detector for use in nuclear resonant scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 0,010.02 cm) with a pixel pitch of 0.015 cm and depletion depth of 0.001 cm. An ultrafast frontend circuit allows the X-ray detector to obtain a high output. High-performance integrated circuits achieve multichannel scaling over 1024 continuous time bins with a 1 ns resolution for each pixel without dead time. The multichannel scaling method enabled us to record a time spectrum of the 14.4 keV nuclear radiation at each pixel with a time resolution of 1.4 ns (FWHM). This method was successfully applied to nuclear forward scattering and nuclear small-angle scattering on Fe.
山本 寿*; 関口 善之*; 石井 愛典*; 鈴木 惣十*; 川島 正俊*; 斉藤 宜弘*; 大西 恒二*
PNC TN941 79-112, 156 Pages, 1979/07
高速実験炉「常陽」の低出力性能試験のうち核出力較正試験と小型核分裂計数管による炉心中心軸上の出力分布試験の結果について述べる。▲原子炉出力は,予め較正されたPu239の小型核分裂計数偶を炉内に挿入し,得られた計数率と,計算によって得られた反応率との対応から求められた。起動系については,計数率と炉出力の関係を求め,中間系は指示計の値と原子炉出力が一致するように調整された。▲本試験の主な結果は次の通りである。▲1)起動系ch1,ch2の計数率と原子炉出力の関係は,0.1kWから10kWの範囲で直線的であることが確認された。▲2)中間系と起動系は,炉出力1kWから10kWの範囲でオーバーラップしており,この区間では中間系の指示値と炉出力の関係は直線的である。▲3)中心軸上の反応率は,Pu239Pu240,U235,U238,Th232の(n,f)反応が小型核分裂計数管によって測定された。軸方向分布の測定値から得られた軸方向ピーキング係数は1.19であり,設計値と一致した。▲4)―次冷却材の温度変化による起動系の計数率は,一次冷却材の温度が100上昇すると,約8%増加する。▲5)燃料貯蔵ラック内の燃料は,起動系の計数率に影響を与える。起動系と炉中心を結ぶ線上のラック内に炉心燃料が一本装荷されると,計数率は約25%増加する。▲その他の核特性として,6)等温係数は一3.6510-3%K/K/(190250)であった。▲7)炉中心において,燃料と試験用特殊燃料集合体の置換反応度は一0.085%K/Kであった。▲