検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 172 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Development of correction method for sample density effect on PGA

前田 亮; 瀬川 麻里子; 藤 暢輔; 遠藤 駿典; 中村 詔司; 木村 敦

Journal of Radioanalytical and Nuclear Chemistry, 332(8), p.2995 - 2999, 2023/08

 被引用回数:0 パーセンタイル:0.01(Chemistry, Analytical)

The accuracy of the prompt $$gamma$$-ray analysis is known to degrade for the samples containing neutron-scattering materials, such as hydrogen, depending on its content. Recently, we discovered that the density of the scattering materials also affects the accuracy. In this paper, we developed a correction method for the effect of the sample densities. The developed correction method is straightforward and applicable to samples with unknown densities. The simulation and experiments verified the performance of the correction method. The results confirmed that the correction method could reduce the uncertainty due to sample density from 47% to approximately 1%.

論文

Water contents in aggregates and cement pastes determined by gravimetric analysis and prompt $$gamma$$-ray analysis

木下 哲一*; 能任 琢真*; 中島 均*; 小迫 和明*; 加藤 雄大*; 黒岩 洋一*; 倉部 美彩子*; 佐々木 勇気*; 鳥居 和敬*; 前田 亮; et al.

Journal of Radioanalytical and Nuclear Chemistry, 332(2), p.479 - 486, 2023/02

There are some different chemical and physical forms of water molecules in concretes. Especially, bound water is difficult to determine. In the present work, we determined free + adsorbed water and bound water contained in aggregates and cement pastes, which are component of concretes, by means of conventional gravimetric analysis and prompt $$gamma$$-ray analysis (PGA), respectively, in order to evaluate a total water content in concretes. In the PGA, background reduction was attempted by using the time-of-flight (TOF) signal. In addition, the degree of contribution to analytical values by scattered neutrons by samples was evaluated because water would adsorb on the surface of instruments inside the irradiation chamber for the PGA. Contents of the free + adsorbed water and bound water in some geochemical references determined in the present work were compared with the nominal values to confirm the precision. Each water content in aggregates collected from different quarries and cement pastes with different water-to-cement ratios were analyzed. A total water content in young concrete was evaluated on the basis of the analytical values.

論文

Measurements of the neutron total and capture cross sections and derivation of the resonance parameters of $$^{181}$$Ta

遠藤 駿典; 木村 敦; 中村 詔司; 岩本 修; 岩本 信之; Rovira Leveroni, G.; 藤 暢輔; 瀬川 麻里子; 前田 亮

Nuclear Science and Engineering, 18 Pages, 2023/00

 被引用回数:1 パーセンタイル:72.91(Nuclear Science & Technology)

The neutron transmission ratio and capture yield for $$^{181}$$Ta were measured in J-PARC MLF ANNRI to improve the accuracy of resonance parameters. The total cross section was determined from the transmission ratio in the energy range from 0.2 to 150 eV. The capture cross section was obtained from the capture yield using the pulse height weighting technique (PHWT) in the energy range from thermal to 150 eV. The obtained transmission ratio and capture cross-section were fitted by the resonance analysis code, REFIT, and the resonance parameters were determined below 150 eV. It was also discussed the correlations caused by fitting based on statistical uncertainty and correlations for systematic uncertainty based on sample thickness in the transmission measurements.

論文

Effect of sample density in prompt $$gamma$$-ray analysis

前田 亮; 瀬川 麻里子; 藤 暢輔; 遠藤 駿典; 中村 詔司; 木村 敦

Scientific Reports (Internet), 12(1), p.6287_1 - 6287_8, 2022/06

 被引用回数:2 パーセンタイル:31.9(Multidisciplinary Sciences)

A high-accuracy analytical method is broadly required to obtain reliable research results. Thus, prompt $$gamma$$-ray analysis (PGA), one of the most accurate non-destructive analytical methods, has been employed in various fields. However, the measurement accuracy of PGA is also known to degrade in hydrogenous samples. The degradation is caused by variation in the measurement sensitivity (counts per milligram) following the change in neutron energy due to scattering with hydrogen nucleus. Number of scatterings is well known to depend on the hydrogen content in a sample. However, considering multiple scatterings, hydrogen density, which has not been taken into account as yet, may also lead to the accuracy degradation. In this research, the effect of the hydrogen density in PGA is investigated by evaluating the measurement sensitivity of samples with the same hydrogen content and different densities. The results showed that the measurement sensitivity varies by more than 30% depending on the hydrogen density even at the same hydrogen content. The variation is a particularly serious problem for PGA requiring a few percent accuracy in most cases. Additionally, although the variation is apparently observed in hydrogenous samples, the similar phenomenon can occur in other nuclides with a large scattering cross section; it may affect nuclear cross-section measurements using neutrons in such fields as astrophysics and nuclear energy.

論文

Investigation of radioactive samples for neutron capture reaction measurements using energy-resolved neutron imaging

瀬川 麻里子; 藤 暢輔; 甲斐 哲也; 木村 敦; 中村 詔司

Annals of Nuclear Energy, 167, p.108828_1 - 108828_5, 2022/03

 被引用回数:0 パーセンタイル:0.01(Nuclear Science & Technology)

To obtain accurate analytical results via neutron-capture reactions, the effects of sample shapes must be considered. However, the estimations of the effects were difficult to verify in some cases such as sealed samples and valuable objects. In this study, the shape effects for sealed radioactive samples were estimated experimentally. The significant localization of the $$^{129}$$I sample was confirmed only by an energy-resolved neutron imaging. It is revealed that the shape effect was necessary to be corrected at the neutron resonance peaks. Consequently, we conclude that the energy-resolved neutron imaging will be quite effective to improve the analytical accuracy.

論文

Neutron capture and total cross-section measurements and resonance parameter analysis of niobium-93 below 400 eV

遠藤 駿典; 木村 敦; 中村 詔司; 岩本 修; 岩本 信之; Rovira Leveroni, G.; 寺田 和司*; 明午 伸一郎; 藤 暢輔; 瀬川 麻里子; et al.

Journal of Nuclear Science and Technology, 59(3), p.318 - 333, 2022/03

 被引用回数:5 パーセンタイル:65.59(Nuclear Science & Technology)

In order to improve the accuracy of the cross-section and the resonance parameters of $$^{93}$$Nb, neutron capture and total cross-sections were measured using the J-PARC MLF ANNRI. The thermal-neutron capture cross-section was deduced as 0.97$$pm$$0.12 b. The resonance parameters of 11 resonances below 400 eV were determined from obtained capture cross-sections and transmission ratios by using the resonance analysis code, REFIT.

論文

Nondestructive quantitative analysis of difficult-to-measure radionuclides $$^{107}$$Pd and $$^{99}$$Tc

藤 暢輔; 瀬川 麻里子; 前田 亮; 常山 正幸*; 木村 敦; 中村 詔司; 遠藤 駿典; 海老原 充*

Analytical Chemistry, 93(28), p.9771 - 9777, 2021/07

 被引用回数:4 パーセンタイル:24.69(Chemistry, Analytical)

Considering the expanding demand for nuclear waste management of the spent nuclear fuel materials in near future, a non-destructive analytical scheme applicable to the most difficult-to-measure nuclide of $$^{107}$$Pd, which emits no decay gamma-rays and whose half-life is too long to be decayed out during a human lifetime, was designed. The scheme consists of a sophisticated instrument capable of the detection of gamma-rays by Ge detectors coupled with time-of-flight measurement of neutrons and a high-intensity pulsed neutron beam, and can simultaneously perform TOF-coupled prompt gamma-ray analysis (TOF-PGA) as well as PGA and NRCA. An analytical capability was evaluated by applying to simulated samples of the Tc-platinum group metals (Tc-PGMs) obtained by the group partitioning process of spent nuclear fuels, which contain not only $$^{107}$$Pd but also $$^{99}$$Tc and another difficult-to-measure fission product. It was confirmed that, although PGA and NRCA could accurately analyze both nuclides in individual single substances, only TOF-PGA can analyze $$^{107}$$Pd as well as $$^{99}$$Tc in the Tc-PGMs simulated sample. The TOF-PGA measurement technique can be widely used for the non-destructive analysis of $$^{107}$$Pd and $$^{99}$$Tc in nuclear wastes.

論文

Neutron capture cross sections of curium isotopes measured with ANNRI at J-PARC

川瀬 頌一郎*; 木村 敦; 原田 秀郎; 岩本 信之; 岩本 修; 中村 詔司; 瀬川 麻里子; 藤 暢輔

Journal of Nuclear Science and Technology, 58(7), p.764 - 786, 2021/07

 被引用回数:2 パーセンタイル:31.78(Nuclear Science & Technology)

The neutron capture cross sections of $$^{244}$$Cm and $$^{246}$$Cm were measured for the neutron energy range of 1-1000 eV via the neutron time-of-flight method with ANNRI at MLF of the J-PARC. The world's most intense neutron pulses from the Japan Spallation Neutron Source enable the accurate measurement of neutron capture cross sections. Besides, single-bunched neutron pulses allow the analysis in a higher neutron energy region than the previous measurement at ANNRI. The resonance analyses were performed up to 1000 eV by using a resonance shape analysis code REFIT. The spectra of prompt gamma-rays from neutron capture reactions of $$^{244}$$Cm and $$^{246}$$Cm were also obtained, and 43 and 10 prompt gamma-ray peaks from $$^{244}$$Cm(n,$$gamma$$) and $$^{246}$$Cm(n,$$gamma$$) reactions were newly observed, respectively.

論文

Feasibility study of PGAA for boride identification in simulated melted core materials

土川 雄介; 阿部 雄太; 大石 佑治*; 甲斐 哲也; 藤 暢輔; 瀬川 麻里子; 前田 亮; 木村 敦; 中村 詔司; 原田 正英; et al.

JPS Conference Proceedings (Internet), 33, p.011074_1 - 011074_6, 2021/03

福島原子力発電所の解体作業では、溶融した燃料棒に含まれるホウ素分布を事前に把握することが重要である。溶融燃料棒の模擬試験体を用意し、ホウ素やホウ化物の含有量を調査する研究が行われてきた。本研究では、その一環として中性子を用いたホウ素並びにホウ化物分布の測定技術開発を行った。ホウ素の中性子吸収に伴う即発ガンマ線を測定し、ホウ素量や二次元分布を測定した。また、n(B,$$alpha$$$$gamma$$)反応における478keV$$gamma$$線は、ホウ素の化合状態により、$$gamma$$線ピークの幅が変化することが知られている。このことを用い、特に溶融燃料棒周辺に存在することが予測されているZrBやFeBといったホウ化物の識別可能性について調査した。測定はJ-PARC/MLFのANNRI, NOBORU, RADENにて行った。これらの解析結果について報告する。

論文

Analytical method for the determination of $$^{211}$$At using an $$alpha$$-scintillation-camera system and thin-layer chromatography

瀬川 麻里子; 西中 一朗*; 藤 暢輔; 前田 亮

Journal of Radioanalytical and Nuclear Chemistry, 326(1), p.773 - 778, 2020/10

 被引用回数:1 パーセンタイル:12.16(Chemistry, Analytical)

$$^{211}$$At is a candidate nuclide for alpha-targeted therapy. In order to use $$^{211}$$At as a pharmaceutical, the radioactivity and chemical forms of generated $$^{211}$$At are the most fundamental specifications that need to be analyzed prior to its medical use. However, previous methods of separately measuring the radioactivity and chemical forms are not adaptable to the medical use of $$^{211}$$At because they cause a severe loss of $$^{211}$$At and do not analyze all the chemical forms of $$^{211}$$At. Therefore, a new analytical method for both the radioactivity and chemical forms of generated $$^{211}$$At is urgently needed. Accordingly, in this study, we developed an experimental system optimized to simultaneously analyze both the radioactivity and chemical forms of a $$^{211}$$At solution to significantly shorten the analysis time; we experimentally verified the accuracy and capabilities of this system at the Japan Atomic Energy Agency. The experiments confirmed that the present system could analyze the radioactivity and all the chemical forms of $$^{211}$$At with an uncertainty of approximately 5% in the region higher than 150 Bq and that it was 200 times more sensitive than the conventional method using an imaging technique with an X-ray imaging plate. As a result, a new method for analyzing the radioactivity and chemical forms of $$^{211}$$At was successfully established and this method will meet the demands for alpha-targeted therapy using $$^{211}$$At. This method will contribute to promoting the stable supply of the medical use of $$^{211}$$At in the near future.

論文

Development of event-type neutron imaging detectors at the energy-resolved neutron imaging system RADEN at J-PARC

Parker, J. D.*; 原田 正英; 林田 洋寿*; 廣井 孝介; 甲斐 哲也; 松本 吉弘*; 中谷 健; 及川 健一; 瀬川 麻里子; 篠原 武尚; et al.

Materials Research Proceedings, Vol.15, p.102 - 107, 2020/05

At the RADEN instrument, we take advantage of the accurate measurement of neutron energy by time-of-flight to perform energy-resolved neutron imaging using event-type neutron imaging detectors. We are continually working to improve these detectors for better spatial resolution and shorter measurement times and, as a user facility, to improve the ease-of-use of their control and analysis software. In particular, we are actively developing a $$^{3}$$He-based gaseous micropattern detector known as the Micro-pixel chamber based Neutron Imaging Detector ($$mu$$ NID). We have recently redesigned the $$mu$$ NID control software to allow full integration into the automated experiment control system at RADEN, and we are carrying out optimization of the analysis algorithms for improved image quality and rate performance.

論文

The Energy-resolved neutron imaging system, RADEN

篠原 武尚; 甲斐 哲也; 及川 健一; 中谷 健; 瀬川 麻里子; 廣井 孝介; Su, Y. H.; 大井 元貴; 原田 正英; 飯倉 寛; et al.

Review of Scientific Instruments, 91(4), p.043302_1 - 043302_20, 2020/04

 被引用回数:51 パーセンタイル:96.48(Instruments & Instrumentation)

The energy-resolved neutron imaging system, RADEN, has been installed at the pulsed neutron source in the Materials and Life Science Experimental Facility of the Japan Proton Accelerator Research Complex. In addition to conventional neutron radiography and tomography, RADEN, the world's first imaging beam-line at a pulsed neutron source, provides three main options for new, quantitative neutron imaging techniques: Bragg-edge imaging to visualize the spatial distribution of crystallographic information, resonance absorption imaging for elemental composition and temperature information, and polarized neutron imaging for magnetic field information. This paper describes the results of characterization studies of the neutronic performance and installed devices at RADEN and shows the results of several demonstration studies for pulsed neutron imaging.

論文

Feasibility study of two-dimensional neutron-resonance thermometry using molybdenum in 316 stainless-steel

甲斐 哲也; 廣井 孝介; Su, Y. H.; 瀬川 麻里子; 篠原 武尚; 松本 吉弘*; Parker, J. D.*; 林田 洋寿*; 及川 健一

Materials Research Proceedings, Vol.15, p.149 - 153, 2020/02

A two-dimensional thermometry technique based on neutron resonance reactions derives the temperature of specified elements in an object by analyzing the Doppler broadening of a neutron resonance measured by a time-analyzing neutron imaging-detector. This technique is expected to be one of the important applications of the energy-resolved neutron imaging system, RADEN, at J-PARC. The authors focused on molybdenum contained in 316 stainless-steel (with a weight fraction of 2-3 wt%). Energy-dependent transmitted neutrons were measured through a 3 mm thick 316 stainless-steel plate placed in a heater at temperatures between 23 and 500 degrees Celsius at RADEN using a gas-electron multiplier (GEM) detector. Thermal and cold neutrons were eliminated from the incident beam by a cadmium filter. The sample area within the neutron beam was 30 by 50 mm$$^2$$. The feasibility is discussed in the presentation.

論文

Neutron capture cross-section measurement and resolved resonance analysis of $$^{237}$$Np

Rovira, G.*; 片渕 竜也*; 登坂 健一*; 松浦 翔太*; 寺田 和司*; 岩本 修; 木村 敦; 中村 詔司; 岩本 信之; 瀬川 麻里子; et al.

Journal of Nuclear Science and Technology, 57(1), p.24 - 39, 2020/01

 被引用回数:10 パーセンタイル:79.13(Nuclear Science & Technology)

The neutron capture cross-section of $$^{237}$$Np has been measured in the neutron energy region of 10 meV to 500 eV. A neutron time-of-flight method was employed using the NaI(Tl) spectrometer in the ANNRI beam-line at the Japanese Proton Accelerator Re-search Complex (J-PARC). The experimental capture yield was derived using the pulse-height weighting technique and an energy dependent cross-section was obtained relative to the incident neutron spectrum derived from a $$^{10}$$B(n, $$alpha$$)$$^{7}$$Li reaction yield. The absolute cross-section was determined by normalizing the results to JENDL-4.0 cross-section data at the first resonance of $$^{237}$$Np. The thermal cross-section was measured to be 177.6 $$pm$$ 3.8 b. The resolved resonance region was analyzed with the REFIT code.

論文

Characteristics of the 2012 model lithium-6 time-analyzer neutron detector (LiTA12) system as a high efficiency detector for resonance absorption imaging

甲斐 哲也; 佐藤 節夫*; 廣井 孝介; Su, Y. H.; 瀬川 麻里子; Parker, J. D.*; 松本 吉弘*; 林田 洋寿*; 篠原 武尚; 及川 健一; et al.

Physica B; Condensed Matter, 551, p.496 - 500, 2018/12

 被引用回数:2 パーセンタイル:10.36(Physics, Condensed Matter)

The 2012 model lithium-6 time-analyzer neutron detector (LiTA12) system, based on a lithium glass scintillator and multi-anode photomultiplier tube, has the highest neutron efficiency among the detectors for pulsed neutron imaging together with a flexibility of the efficiency by changing the thickness of the lithium glass. The authors expect this detector system could become a main detector system for the energy-resolved neutron imaging system, RADEN, at J-PARC, and have started evaluation of the LiTA12 system. For example, spatial resolution for resonance absorption imaging was evaluated by using a line-pair pattern made by 3 micro meter thick gold on a quartz plate. Less than 1 mm width line pairs were resolved at an 8 Mcps neutron counting rate and around 5 eV neutron energy.

論文

Spatial resolution test targets made of gadolinium and gold for conventional and resonance neutron imaging

瀬川 麻里子; 及川 健一; 甲斐 哲也; 篠原 武尚; 林田 洋寿*; 松本 吉弘*; Parker, J. D.*; 中谷 健; 廣井 孝介; Su, Y. H.; et al.

JPS Conference Proceedings (Internet), 22, p.011028_1 - 011028_8, 2018/11

We have fabricated and utilized spatial resolution test targets made of gadolinium and gold for conventional and resonance neutron imaging performed at RADEN, located at beam line BL22 of the J-PARC Materials and Life Science Experimental Facility (MLF). RADEN covers a broad energy range from cold neutrons to high-energy neutrons with energy of several tens keV and was designed to perform energy-resolved neutron imaging utilizing two-dimensional detectors combined with the accurate measurement of neutron energy by the time-of-flight method. The test targets were designed to verify the spatial resolution and image uniformity of two kinds of neutron detectors, counting-type detectors and camera-type detectors. In this presentation, we report the details of these two-dimensional test targets, and the results of demonstrations using the test targets with our neutron imaging detectors. This work was supported in part by the Photon and Quantum Basic Research Coordinated Development Program from the Ministry of Education, Culture, Sports, Science and Technology, Japan.

論文

Reliability estimation of neutron resonance thermometry using tantalum and tungsten

甲斐 哲也; 廣井 孝介; Su, Y. H.; 篠原 武尚; Parker, J. D.*; 松本 吉弘*; 林田 洋寿*; 瀬川 麻里子; 中谷 健; 及川 健一; et al.

Physics Procedia, 88, p.306 - 313, 2017/06

 被引用回数:4 パーセンタイル:85.09(Instruments & Instrumentation)

Neutron resonance thermometry, which measures material temperature by analyzing the Doppler broadening of a neutron resonance peak, is one of the applications of energy-resolved neutron imaging at RADEN of J-PARC. Although this technique is promising, advantages and disadvantages have not been discussed in practical applications. The authors measured neutron transmission rates of tantalum and tungsten foils in a heater chamber up to 300 degrees Celsius at RADEN. The energy-dependent neutron transmission rates with different statistics were obtained after the measurements by selecting arbitrary measuring intervals from one measurement, and the temperatures of the foils were estimated from those transmission rates with different statistics. The reliability of the neutron resonance thermometry with statistical accuracy, irradiation time and spatial resolution are discussed.

論文

Final design of the energy-resolved neutron imaging system "RADEN" at J-PARC

篠原 武尚; 甲斐 哲也; 及川 健一; 瀬川 麻里子; 原田 正英; 中谷 健; 大井 元貴; 相澤 一也; 佐藤 博隆*; 加美山 隆*; et al.

Journal of Physics; Conference Series, 746, p.012007_1 - 012007_6, 2016/00

 被引用回数:57 パーセンタイル:99.88(Physics, Nuclear)

パルス中性子イメージング専用装置「螺鈿」がJ-PARCの物質生命科学実験施設(MLF)に建設され、2014年11月にファーストビームを受け入れた後、装置調整と試験測定を実施中である。この装置の目的は、短パルス中性子源から得られるパルス中性子ビームの特徴を活かして、近年注目されているエネルギー分析型中性子イメージング技術を実用化し、応用研究を世界に先駆けて実施することにあり、同時に日本における最先端の中性子イメージング装置としての役割を果たすことにある。本発表では、「螺鈿」の現状について説明するとともに、コミッショニングの状況と応用研究の実施例について報告する。

論文

Development of a three-dimensional computed tomography system using high-speed camera at a pulsed neutron source

瀬川 麻里子; 大井 元貴; 甲斐 哲也; 篠原 武尚; 佐藤 博隆*; 呉田 昌俊

JPS Conference Proceedings (Internet), 8, p.036006_1 - 036006_6, 2015/09

A neutron energy resolved three-dimensional (3D) imaging system with a high-speed video camera (CMOS, 1300 k frame/sec) and time-of-flight technique has been newly developed and installed at Japan Proton Accelerator Research Complex (J-PARC). The aim is to investigate a spatial distribution of several elements and crystals in various kinds of materials or substances more rapidly. The system allows to obtain TOF images consecutively resolved into narrow energy ranges in the pulsed neutron energy region from 0.01 to a few keV. The camera system was successfully demonstrated to obtain the reconstructed 3D images for Cu, Fe, Pb, and Polyethylene samples and the neutron energy dependence of the CT values, which are proportional to the total neutron cross sections. With use of the energy dependence of each CT values, it is possible to emphasize the selected materials, even if materials such as Cu and Fe have similar energy dependence of CT values. The results showed that this technique has the possibility to visualize material alternatively by choosing neutron energy and emphasize materials with use of the energy dependence of CT values.

論文

Development of a pulsed neutron three-dimensional imaging system using a highly sensitive image-intensifier at J-PARC

瀬川 麻里子; 大井 元貴; 甲斐 哲也; 篠原 武尚; 呉田 昌俊; 坂本 健作; 伊巻 正*

Nuclear Instruments and Methods in Physics Research A, 769, p.97 - 104, 2015/01

 被引用回数:2 パーセンタイル:17.57(Instruments & Instrumentation)

In order to realize neutron energy resolved three-dimensional (3D) imaging at resonance neutron energy region, a camera system coupled with a high sensitive and high frame-rate gating image-intensifier was developed. The resonance absorption 3D imaging was successfully demonstrated at pulsed neutron source of Japan Proton Accelerator Research Complex (J-PARC). The camera system allowed us to obtain a Time-of-flight (TOF) image of 2352 (W) $$times$$ 1726 (H) pixels resolved into a narrow energy range. The 3D images having enhanced contrast at corresponding resonance energy regions for cylindrical Au, Ta and In samples were reconstructed by "Convolution Filtered Back-Projection (FBP)" and "Maximum Likelihood Expectation Maximization (MLEM)" methods. And qualities of spatial resolutions in the depth direction were evaluated to be about 1 mm experimentally. The results obtained in the present experiments showed that the system could have the ability to adjust the practical use in the industrial field.

172 件中 1件目~20件目を表示