稲葉 学*; 穴吹 拓也*; 白井 和貴*; 矢花 修一*; 北村 誠司
Proceedings of 2009 ASME Pressure Vessels and Piping Division Conference (PVP 2009) (CD-ROM), 8 Pages, 2009/07
This paper describes the dynamic damage test of a reinforced concrete (RC) wall structure with seismic isolation system. Shaking table tests were carried out at "E-Defense". The specimen was composed of an upper structure of 600 ton by weight and six lead-rubber bearings (LRBs) of 505 mm in diameter. The RC wall structure was designed so that the damage of the RC wall occurred between the shear force at the hardening of the rubber bearings and that at their breaking. The shaking table test was conducted consecutively by increasing the levels up to 225% of tentative design earthquake motion. Consequently, because of the increase of the structural response by the hardening of the rubber bearings, the damage of the wall structure with seismic isolation system suddenly happened. In addition, the preliminary finite element analysis simulated the test results fairly well.
白井 和貴*; 梅木 克彦*; 矢花 修一*; 北村 誠司
no journal, ,
大型震動台E-ディフェンスを使用した水平免震プラント震動台試験から得られた結果に基づき、設計地震動レベルの入力に対する試験体の応答性状(免震効果や積層ゴム挙動等)について報告する。
佐野 剛志*; 白井 和貴*; 矢花 修一*; 北村 誠司
no journal, ,
大型震動台を用いた免震システムの終局挙動把握試験を実施した。本報告では、設計地震動レベルの入力に対する試験体の各種応答性状について述べる。
稲葉 学*; 白井 和貴*; 矢花 修一*; 平田 和太*; 北村 誠司
no journal, ,
大型振動台を用いた免震システムの終局挙動試験を実施した。本報告では、免震層の鉛直特性を分析して得られた等価剛性を用いることで、模擬性の良好なシミュレーションができたことについて述べる。