検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 112 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

A Systematic approach for the adequacy analysis of a set of experimental databases: Application in the framework of the ATRIUM activity

Baccou, J.*; Glantz, T.*; Ghione, A.*; Sargentini, L.*; Fillion, P.*; Damblin, G.*; Sueur, R.*; Iooss, B.*; Fang, J.*; Liu, J.*; et al.

Nuclear Engineering and Design, 421, p.113035_1 - 113035_16, 2024/05

In the Best-Estimate Plus Uncertainty (BEPU) framework, the use of best-estimate code requires to go through a Verification, Validation and Uncertainty Quantification process (VVUQ). The relevance of the experimental data in relation to the physical phenomena of interest in the VVUQ process is crucial. Adequacy analysis of selected experimental databases addresses this problem. The outcomes of the analysis can be used to select a subset of relevant experimental data, to encourage designing new experiments or to drop some experiments from a database because of their substantial lack of adequacy. The development of a specific transparent and reproducible approach to analyze the relevance of experimental data for VVUQ still remains open and is the topic of this contribution. In this paper, the concept of adequacy initially introduced in the OECD/NEA SAPIUM (Systematic APproach for model Input Uncertainty quantification Methodology) activity is formalized. It is defined through two key properties, called representativeness and completeness, that allows considering the multifactorial dimension of the adequacy problem. A new systematic approach is then proposed to analyze the adequacy of a set of experimental databases. It relies on the introduction of two sets of criteria to characterize representativeness and completeness and on the use of multi-criteria decision analysis method to perform the analysis. Finally, the approach is applied in the framework of the new OECD/NEA ATRIUM activity which includes a set of practical IUQ exercises in thermal-hydraulics to test the SAPIUM guideline in determining input uncertainties and forward propagating them on an application case. It allows evaluating the adequacy of eight experimental databases coming from the Super Moby-dick, Sozzi-Sutherland and Marviken experiments and identifying the most adequate ones.

報告書

Data report of ROSA/LSTF experiment TR-LF-15; Accident management actions during station blackout transient with pump seal LOCA

竹田 武司

JAEA-Data/Code 2023-012, 75 Pages, 2023/10

JAEA-Data-Code-2023-012.pdf:4.45MB

ROSA-V計画において、大型非定常実験装置(LSTF)を用いた実験(実験番号: TR-LF-15)が2014年6月11日に行われた。ROSA/LSTFTR-LF-15実験では、加圧水型原子炉(PWR)のポンプシール冷却材喪失事故(LOCA)を伴う、補助給水機能喪失を特徴とするTMLB'のシナリオでの全交流電源喪失時のアクシデントマネジメント(AM)策を模擬した。ポンプシールLOCAは、0.1%低温側配管破断により模擬した。このとき、非常用炉心冷却系(ECCS)である高圧注入系及び低圧注入系の全故障とともに、ECCSの蓄圧注入タンクから一次系への非凝縮性ガス(窒素ガス)の流入を仮定した。蒸気発生器(SG)二次側水位が特定の低水位まで低下すると、一次系圧力は上昇に転じた。SG二次側水位喪失後、加圧器の安全弁が周期的に開いたため、一次冷却材の喪失につながった。故に、高圧条件でボイルオフによる炉心露出が生じた。模擬燃料棒被覆管表面温度の10Kの上昇を確認した時点で、SG二次側減圧を一番目のAM策として開始した。このAM策では、両SGの安全弁を開放した。また、一番目のAM策開始後少し遅れた時点で、加圧器の安全弁の開放による一次系減圧を二番目のAM策として開始した。さらに、一番目のAM策に従いSG二次側圧力が1.0MPaに低下した時点で、低水頭ポンプによる給水ラインから両SG二次側への注水を三番目のAM策として開始した。三番目のAM策の開始直後、SG二次系からの除熱が再開したため、一次系圧力の低下が促進された。蓄圧注入系から両低温側配管への冷却材注入による炉心水位の回復により、全炉心はクエンチした。窒素ガスがSGU字管内に蓄積したため、一次系の減圧率は低下した。本報告書は、ROSA/LSTFTR-LF-15実験の手順、条件および実験で観察された主な結果をまとめたものである。

報告書

Data report of ROSA/LSTF experiment IB-HL-01; 17% hot leg intermediate break LOCA with totally-failed high pressure injection system

竹田 武司

JAEA-Data/Code 2023-007, 72 Pages, 2023/07

JAEA-Data-Code-2023-007.pdf:3.24MB

ROSA-V計画において、大型非定常実験装置(LSTF)を用いた実験(実験番号:IB-HL-01)が2009年11月19日に行われた。ROSA/LSTF IB-HL-01実験では、加圧水型原子炉(PWR)の加圧器サージラインの両端ギロチン破断による17%高温側配管中破断冷却材喪失事故を模擬した。このとき、高温側配管内面に接する様に、長いノズルを上向きに取り付けることにより破断口を模擬した。また、非常用炉心冷却系(ECCS)である高圧注入系の全故障と補助給水系の全故障を仮定した。実験では、比較的大きいサイズの破断が早い過渡現象を引き起こした。破断後一次系圧力が急激に低下し、蒸気発生器(SG)二次側圧力よりも低くなった。破断流は、破断直後に水単相から二相流に変化した。炉心露出は、ループシールクリアリング(LSC)前に、クロスオーバーレグの下降流側の水位低下と同時に開始した。低温側配管に注入されたECCSの蓄圧注入系(ACC)冷却水の蒸気凝縮により両ループのLSCが誘発された。LSC後の炉心水位の急速な回復により、全炉心はクエンチした。模擬燃料棒被覆管最高温度は、LSCとほぼ同時に検出された。ACC冷却水注入時、高速蒸気流による高温側配管からSG入口プレナムへの液体のエントレインメントにより、高温側配管とSG入口プレナムの水位が回復した。ECCSである低圧注入系の作動を通じた継続的な炉心冷却を確認後、実験を終了した。本報告書は、ROSA/LSTF IB-HL-01実験の手順、条件および実験で観察された主な結果をまとめたものである。

報告書

Data report of ROSA/LSTF experiment SB-PV-09; 1.9% pressure vessel top small break LOCA with SG depressurization and gas inflow

竹田 武司

JAEA-Data/Code 2021-006, 61 Pages, 2021/04

JAEA-Data-Code-2021-006.pdf:2.78MB

ROSA-V計画において、大型非定常実験装置(LSTF)を用いた実験(実験番号: SB-PV-09)が2005年11月17日に行われた。ROSA/LSTF SB-PV-09実験では、加圧水型原子炉(PWR)の1.9%圧力容器頂部小破断冷却材喪失事故を模擬した。このとき、非常用炉心冷却系(ECCS)である高圧注入系の全故障と蓄圧注入(ACC)タンクから一次系への非凝縮性ガス(窒素ガス)の流入を仮定した。実験では、上部ヘッドに形成される水位が破断流量に影響を与えることを見出した。アクシデントマネジメント(AM)策として、両ループの蒸気発生器(SG)逃し弁開放によるSG二次側減圧を炉心出口最高温度が623Kに到達した時点で開始した。SG二次側圧力が一次系圧力に低下するまで、このAM策は一次系減圧に対して有効とならなかった。一方、炉心出口温度の応答が遅くかつ緩慢であるため、模擬燃料棒の被覆管表面最高温度がLSTFの炉心保護のために予め決定した値(958K)を超えたとき、炉心出力は自動的に低下した。炉心出力の自動低下後、低温側配管内でのACC水と蒸気の凝縮により両ループのループシールクリアリング(LSC)が誘発された。LSC後、炉心水位が回復して炉心はクエンチした。ACCタンクから窒素ガスの流入開始後、一次系とSG二次側の圧力差が大きくなった。ECCSである低圧注入系の作動を通じた継続的な炉心冷却を確認後、実験を終了した。本報告書は、ROSA/LSTF SB-PV-09実験の手順、条件および実験で観察された主な結果をまとめたものである。

報告書

Data report of ROSA/LSTF experiment SB-SL-01; Main steam line break accident

竹田 武司

JAEA-Data/Code 2020-019, 58 Pages, 2021/01

JAEA-Data-Code-2020-019.pdf:3.85MB

ROSA-IV計画において、大型非定常実験装置(LSTF)を用いた実験(実験番号: SB-SL-01)が1990年3月27日に行われた。ROSA/LSTFSB-SL-01実験では、加圧水型原子炉(PWR)の主蒸気管破断(MSLB)事故を模擬した。このとき、両ループの蒸気発生器(SG)二次側への補助給水(AFW)とともに、非常用炉心冷却系である高圧注入(HPI)系から両ループの低温側配管内への冷却材注入を仮定した。MSLBにより、破断ループのSGは急減圧し、破断ループのSG二次側広域水位は低下した。しかし、破断ループのSG二次側へのAFWにより、破断ループのSG二次側広域水位は回復した。一次系圧力は、MSLB直後一時的に若干低下したが、SG主蒸気隔離弁の閉止に従い16.1MPaまで上昇した。一次系圧力が10MPa以下に低下した数分後、HPI系から両ループの低温側配管内へ冷却材を手動注入した。一次系圧力は、HPI系からの冷却材注入により上昇したが、加圧器逃し弁の開放により16.2MPa以下に維持された。実験中、炉心はサブクール水で満たされた。健全ループでは、流れが停滞し、HPI系からの冷却材注入時に低温側配管での温度成層が観察された。一方、破断ループでは、顕著な自然循環が継続した。HPI系からの冷却材の連続注入による継続的な炉心冷却を確認して実験を終了した。取得した実験データは、PWRのMSLBを伴う多重故障事故時の回復操作および手順の検討に役立てることができる。本報告書は、ROSA/LSTFSB-SL-01実験の手順、条件および実験で観察された主な結果をまとめたものである。

論文

Major outcomes through recent ROSA/LSTF experiments and future plans

竹田 武司; 和田 裕貴; 柴本 泰照

World Journal of Nuclear Science and Technology, 11(1), p.17 - 42, 2021/01

Many experiments have been conducted on accidents and transients of pressurized water reactor (PWR) employing the rig of safety assessment/large-scale test facility (ROSA/LSTF). Major results of the related integral effect tests with the LSTF were reviewed to experimentally identify thermal-hydraulic phenomena involved, regarding the PWR accident sequences in accordance with the new regulatory requirements for the Japanese light-water nuclear power plants. Key results of the recent integral effect tests utilizing the LSTF and future plans were presented relevant to multiple steam generator tube rupture accident with recovery operation, small-break loss-of-coolant accident (LOCA) with accident management measure on core exit temperature reliability, and small-break LOCA with thermal stratification under cold water injection from emergency core cooling system into cold legs.

論文

ROSA/LSTF test on nitrogen gas behavior during reflux condensation in PWR and RELAP5 code analyses

竹田 武司; 大津 巌

Mechanical Engineering Journal (Internet), 5(4), p.18-00077_1 - 18-00077_14, 2018/08

We conducted an experiment focusing on nitrogen gas behavior during reflux condensation in PWR with ROSA/LSTF. The primary pressure was lower than 1 MPa under constant core power of 0.7% of volumetric-scaled (1/48) PWR nominal power. Steam generator (SG) secondary-side collapsed liquid level was maintained at certain liquid level above SG U-tube height. Nitrogen gas was injected stepwise into each SG inlet plenum at certain constant amount. The primary pressure and degree of subcooling of SG U-tubes were largely dependent on amount of nitrogen gas accumulated in SG U-tubes. Nitrogen gas accumulated from outlet towards inlet of SG U-tubes. Non-uniform flow behavior was observed among SG U-tubes with nitrogen gas ingress. The RELAP5/MOD3.3 code indicated remaining problems in predictions of the primary pressure and degree of subcooling of SG U-tubes depending on number of nitrogen gas injection. We studied further non-uniform flow behavior through sensitivity analyses.

論文

Uncertainty analysis of ROSA/LSTF test by RELAP5 code and PKL counterpart test concerning PWR hot leg break LOCAs

竹田 武司; 大津 巌

Nuclear Engineering and Technology, 50(6), p.829 - 841, 2018/08

 被引用回数:13 パーセンタイル:80.12(Nuclear Science & Technology)

An experiment was conducted for OECD/NEA ROSA-2 Project using LSTF, which simulated 17% hot leg intermediate-break LOCA in PWR. Core uncovery started simultaneously with liquid level drop in crossover leg downflow-side before loop seal clearing, and water remaining occurred on upper core plate. Results of uncertainty analysis with RELAP5/MOD3.3 code clarified influences of combination of multiple uncertain parameters on peak cladding temperature within defined uncertain ranges. An experiment was performed for OECD/NEA PKL-3 Project with PKL. The LSTF test simulated PWR 1% hot leg small-break LOCA with steam generator secondary-side depressurization as accident management measure and nitrogen gas inflow. Some discrepancies appeared between the LSTF and PKL test results for primary pressure, core collapsed liquid level, and cladding surface temperature probably due to effects of differences between LSTF and PKL in configuration, geometry, and volumetric size.

報告書

Data report of ROSA/LSTF experiment SB-SG-10; Recovery actions from multiple steam generator tube rupture accident

竹田 武司

JAEA-Data/Code 2018-004, 64 Pages, 2018/03

JAEA-Data-Code-2018-004.pdf:3.33MB

LSTFを用いた実験(実験番号:SB-SG-10)が1992年11月17日に行われた。SB-SG-10実験では、PWRの蒸気発生器(SG)伝熱管複数本破損事故からの回復操作を模擬した。高圧注入(HPI)系から低温側配管や高温側配管への冷却材注入により、健全ループSGの逃し弁(RV)開放を開始しても一次系圧力はSG二次側圧力よりも高く維持された。しかし、加圧器(PZR)の逃し弁(PORV)開放により、PZRの水位が回復するとともに、一次系と破断ループSG二次側の圧力は均圧した。放射性物質の大気放出に関して、健全ループSGのRV開放後、破断ループSGのRVは一回開いた。実験中、炉心は飽和ないしサブクール水で満たされた。健全ループSGのRV開放後、健全ループで顕著な自然循環が継続した。また、特に両ループのHPI系から高温側配管への冷却材注入時に高温側配管での顕著な温度成層が生じた。一次系と破断ループSG二次側の圧力が均圧後、健全ループ一次系冷却材ポンプの再起動による冷温停止状態を確認して実験を終了した。本報告書は、SB-SG-10実験の手順、条件および実験で観察された主な結果をまとめたものである。

報告書

Data report of ROSA/LSTF experiment SB-PV-07; 1% Pressure vessel top break LOCA with accident management actions and gas inflow

竹田 武司

JAEA-Data/Code 2018-003, 60 Pages, 2018/03

JAEA-Data-Code-2018-003.pdf:3.68MB

LSTFを用いた実験(実験番号:SB-PV-07)が2005年6月9日に行われた。SB-PV-07実験では、PWRの1%圧力容器頂部小破断冷却材喪失事故を模擬した。このとき、高圧注入(HPI)系の全故障と蓄圧注入(ACC)タンクから一次系への非凝縮性ガス(窒素ガス)の流入を仮定した。実験では、上部ヘッドに形成される水位が破断流量に影響を与えることを見出した。一番目のアクシデントマネジメント(AM)策として、手動による両ループのHPI系から低温側配管への冷却材の注入を炉心出口最高温度が623Kに到達した時点で開始した。炉心出口温度の応答が遅くかつ緩慢であるため、燃料棒表面温度は大きく上昇した。AM策に従い、炉心水位が回復して炉心はクエンチした。また、二番目のAM策として、両ループの蒸気発生器(SG)逃し弁開放によるSG二次側減圧を一次系圧力が4MPaに低下した時点で開始したが、SG二次側圧力が一次系圧力に低下するまで一次系減圧に対して有効とならなかった。ACCタンクから窒素ガスの流入開始後、一次系とSG二次側の圧力差が大きくなった。本報告書は、SB-PV-07実験の手順、条件および実験で観察された主な結果をまとめたものである。

論文

ROSA/LSTF tests and posttest analyses by RELAP5 code for accident management measures during PWR station blackout transient with loss of primary coolant and gas inflow

竹田 武司; 大津 巌

Science and Technology of Nuclear Installations, 2018, p.7635878_1 - 7635878_19, 2018/00

 被引用回数:2 パーセンタイル:21.23(Nuclear Science & Technology)

Three tests were carried out with LSTF, simulating accident management (AM) measures during PWR station blackout transient with loss of primary coolant under assumptions of nitrogen gas inflow and total-failure of high-pressure injection system. As AM measures, steam generator (SG) depressurization was done by fully opening relief valves, and auxiliary feedwater was injected into secondary-side simultaneously. Conditions for break size and onset timing of AM measures were different. Primary pressure decreased to below 1 MPa with or without primary depressurization by fully opening pressurizer relief valve. Nonuniform flow behaviors were observed in SG U-tubes with gas ingress depending on gas accumulation rate in two tests that gas accumulated remarkably. The RELAP5/MOD3.3 code indicated remaining problems in predictions of primary pressure, SG U-tube liquid levels, and natural circulation mass flow rates after gas inflow and accumulator flow rate through analyses for two tests.

論文

RELAP5 uncertainty evaluation using ROSA/LSTF test data on PWR 17% cold leg intermediate-break LOCA with single-failure ECCS

竹田 武司; 大津 巌

Annals of Nuclear Energy, 109, p.9 - 21, 2017/11

 被引用回数:7 パーセンタイル:61.68(Nuclear Science & Technology)

An experiment was conducted for the OECD/NEA ROSA-2 Project using LSTF, which simulated a cold leg intermediate-break loss-of-coolant accident with 17% break in a PWR. Assumptions were made such as single-failure of high-pressure and low-pressure injection systems. In the LSTF test, core dryout took place because of rapid drop in the core liquid level. Liquid was accumulated in upper plenum, SG U-tube upflow-side and inlet plena because of counter-current flow limiting (CCFL). The post-test analysis by RELAP5/MOD3.3 code revealed that peak cladding temperature (PCT) was overpredicted because of underprediction of the core liquid level due to inadequate prediction of accumulator flow rate. We found the combination of multiple uncertain parameters including the Wallis CCFL correlation at the upper core plate, core decay power, and steam convective heat transfer coefficient in the core within the defined uncertain ranges largely affected the PCT.

論文

ROSA/LSTF test and RELAP5 analyses on PWR cold leg small-break LOCA with accident management measure and PKL counterpart test

竹田 武司; 大津 巌

Nuclear Engineering and Technology, 49(5), p.928 - 940, 2017/08

 被引用回数:4 パーセンタイル:37.32(Nuclear Science & Technology)

An experiment using PKL was performed for the OECD/NEA PKL-3 Project as a counterpart to a previous test with LSTF on a cold leg small-break loss-of-coolant accident with an accident management measure in a PWR. The rate of steam generator secondary-side depressurization was controlled to achieve a primary depressurization rate of 200 K/h as a common test condition. In both tests, rapid recovery started in the core collapsed liquid level after loop seal clearing. Some discrepancies appeared between the LSTF and PKL test results for the core collapsed liquid level, the cladding surface temperature, and the primary pressure. The RELAP5/MOD3.3 code indicated a remaining problem in the prediction of primary coolant distribution. Results of uncertainty analysis for the LSTF test clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges.

論文

ROSA/LSTF test on nitrogen gas behavior during reflux cooling in PWR and RELAP5 post-test analysis

竹田 武司; 大津 巌

Proceedings of 25th International Conference on Nuclear Engineering (ICONE-25) (CD-ROM), 11 Pages, 2017/07

An experiment focusing on nitrogen gas behavior during reflux cooling in a PWR was performed with the LSTF. The test conditions were made such as the constant core power of 0.7% of the volumetric-scaled PWR nominal power and the primary pressure of lower than 1 MPa. The steam generator (SG) secondary-side collapsed liquid level was maintained at a certain liquid level above the SG tube height. Nitrogen gas was injected stepwise into each SG inlet plenum at a certain constant amount. The primary pressure and the SG U-tube fluid temperatures were greatly dependent on the amount of nitrogen gas accumulated in the SG U-tubes. Non-uniform flow behavior was observed among the SG U-tubes with nitrogen gas ingress. The RELAP5/MOD3.3 code indicated remaining problems in the predictions of the primary pressure and the SG U-tube fluid temperatures after nitrogen gas inflow.

報告書

Data report of ROSA/LSTF experiment TR-LF-07; Loss-of-feedwater transient with primary feed-and-bleed operation

竹田 武司

JAEA-Data/Code 2016-004, 59 Pages, 2016/07

JAEA-Data-Code-2016-004.pdf:3.34MB

LSTFを用いた実験(実験番号: TR-LF-07)が1992年6月23日に行われた。TR-LF-07実験では、PWRの給水喪失事象を模擬した。このとき、一次系フィード・アンド・ブリード運転とともに、補助給水系の不作動を仮定した。また、蒸気発生器(SG)の二次側水位が3mまで低下した時点でSI信号を発信し、その後30分で加圧器(PZR)の逃し弁(PORV)開放による一次系減圧を開始した。さらに、SI信号発信後12秒でPZRの有るループの高圧注入系(HPI)の作動を開始し、一次系圧力が10.7MPaまで低下した時点でPZRの無いループのHPIの作動を開始した。一次系とSG二次側の圧力は、PZRのPORVとSGの逃し弁の周期的開閉によりほぼ一定に維持された。PORVの開放にしたがい、PZRの水位が大きく低下し始め、高温側配管では水位が形成した。HPIの作動により、PZRと高温側配管の水位は回復した。一次系圧力はSG二次側圧力を下回り、両ループの蓄圧注入系(ACC)が作動した。炉心露出が生じなかったことから、PORV, HPIおよびACCを用いた一次系フィード・アンド・ブリード運転は、炉心冷却に有効であった。本報告書は、TR-LF-07実験の手順、条件および実験で観察された主な結果をまとめたものである。

報告書

Data report of ROSA/LSTF experiment SB-HL-12; 1% Hot leg break LOCA with SG depressurization and gas inflow

竹田 武司

JAEA-Data/Code 2015-022, 58 Pages, 2016/01

JAEA-Data-Code-2015-022.pdf:3.31MB

LSTFを用いた実験(実験番号: SB-HL-12)が1998年2月24日に行われた。SB-HL-12実験では、PWRの1%高温側配管小破断冷却材喪失事故を模擬した。このとき、高圧注入系の全故障とともに、蓄圧注入系(ACC)タンクからの非凝縮性ガス(窒素ガス)の流入を仮定した。また、アクシデントマネジメント(AM)策として両ループの蒸気発生器(SG)逃し弁全開による減圧を燃料棒表面最高温度が600Kに到達直後に開始した。一回目のボイルオフによる炉心露出に起因したAM策開始後、一次系圧力は低下したため、炉心二相混合水位は上昇し、燃料棒表面温度は635Kまでの上昇にとどまった。低温側配管内でのACC水と蒸気の凝縮に誘発されたループシールクリアリング(LSC)前に、二回目のボイルオフによる炉心露出が生じた。LSC後速やかに炉心水位は回復し、燃料棒表面温度は696Kまでの上昇にとどまった。窒素ガスの流入開始後、一次系とSG二次側の圧力差が大きくなった。SG伝熱管でのリフラックス凝縮時に、三回目のボイルオフによる炉心露出が生じ、燃料棒表面最高温度が908Kを超えた。本報告書は、SB-HL-12実験の手順、条件および実験で観察された主な結果をまとめたものである。

論文

ROSA/LSTF tests and RELAP5 posttest analyses for PWR safety system using steam generator secondary-side depressurization against effects of release of nitrogen gas dissolved in accumulator water

竹田 武司; 大貫 晃*; 金森 大輔*; 大津 巌

Science and Technology of Nuclear Installations, 2016, p.7481793_1 - 7481793_15, 2016/00

AA2016-0048.pdf:5.15MB

 被引用回数:1 パーセンタイル:10.78(Nuclear Science & Technology)

Two tests related to a new safety system for PWR were performed with ROSA/LSTF. The tests simulated cold leg small-break loss-of-coolant accidents with 2-inch diameter break using an early steam generator (SG) secondary-side depressurization with or without release of nitrogen gas dissolved in accumulator (ACC) water. The pressure difference between the primary and SG secondary sides after the actuation of ACC system was larger in the test with the dissolved gas release than in the test without the dissolved gas release. No core uncovery and heatup took place because of the ACC coolant injection and two-phase natural circulation. The RELAP5 code predicted most of the overall trends of the major thermal-hydraulic responses after adjusting a break discharge coefficient for two-phase discharge flow under the assumption of releasing all the dissolved gas at the vessel upper plenum.

論文

ROSA/LSTF experiment on a PWR station blackout transient with accident management measures and RELAP5 analyses

竹田 武司; 大津 巌

Mechanical Engineering Journal (Internet), 2(5), p.15-00132_1 - 15-00132_15, 2015/10

An experiment on a PWR station blackout transient with accident management (AM) measures was conducted using the ROSA/LSTF under an assumption of non-condensable gas inflow to primary system from accumulator tanks. The AM measures considered are SG secondary-side depressurization by fully opening safety valves in both SGs with start of core uncovery and coolant injection into the secondary-side of both SGs at low pressures. The primary pressure started to decrease when the SG primary-to-secondary heat removal resumed soon after the SG secondary-side coolant injection. The primary depressurization worsened due to the gas accumulation in SG U-tubes after accumulator completion. The RELAP5 code indicated remaining problems in the predictions of the SG U-tube collapsed liquid level and primary mass flow rate after gas ingress. The SG coolant injection flow rate was found to significantly affect the peak cladding temperature and the ACC actuation time through RELAP5 sensitivity analyses.

論文

Thermal hydraulic safety research at JAEA after the Fukushima Dai-ichi Nuclear Power Station accident

与能本 泰介; 柴本 泰照; 竹田 武司; 佐藤 聡; 石垣 将宏; 安部 諭; 岡垣 百合亜; 孫 昊旻; 栃尾 大輔

Proceedings of 16th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-16) (USB Flash Drive), p.5341 - 5352, 2015/08

This paper summarizes thermal-hydraulic (T/H) safety studies being conducted at JAEA based on the consideration of research issues after the Fukushima Dai-Ichi Nuclear Power Station accident. New researches have been initiated after the accident, which are related to containment thermal hydraulics and accident management (AM) measures for the prevention of core damage under severe multiple failure conditions. They are conducted in parallel with those initiated before the accident such as a research on scaling and uncertainty of the T/H phenomena which are important for the code validation. Those experimental studies are to obtain better understandings on the phenomena and establish databases for the validation of both lumped parameter (LP) and computational fluid dynamics (CFD) codes. The research project on containment thermal hydraulics is called the ROSA-SA project and investigates phenomena related to over-temperature containment damage, hydrogen risk and fission product (FP) transport. For this project, we have designed a large-scale containment vessel test facility called CIGMA (Containment InteGral Measurement Apparatus), which is characterized by the capability of conducting high-temperature experiments as well as those on hydrogen risk with CFD-grade instrumentation of high space resolution. This paper describes the plans for those researches and results obtained so far.

論文

ROSA/LSTF experiment on accident management measures during a PWR station blackout transient with pump seal leakage and RELAP5 analyses

竹田 武司; 大津 巌

Journal of Energy and Power Sources, 2(7), p.274 - 290, 2015/07

An experiment on accident management (AM) measures during a PWR station blackout transient with leakage from primary coolant pump seals was conducted using the ROSA/LSTF under an assumption of non-condensable gas inflow to the primary system from accumulator tanks. The AM measures are steam generator (SG) secondary-side depressurization by fully opening safety valves (SVs) in both SGs and primary-side depressurization by fully opening SV in pressurizer with the start of core uncovery and coolant injection into the SG secondary-side at low pressures. The decrease was accelerated in the primary pressure when the SG primary-to-secondary heat removal resumed soon after the coolant injection into the SG secondary-side. The primary depressurization worsened due to the gas accumulation in the SG U-tubes after accumulator completion. Remaining problems in the RELAP5 code include the predictions of pressure difference between the primary and SG secondary sides after the gas inflow.

112 件中 1件目~20件目を表示